Obesity hypoventilation syndrome (OHS) is defined as a combination of obesity (body mass index ≥30 kg·m
), daytime hypercapnia (arterial carbon dioxide tension ≥45 mmHg) and sleep disordered ...breathing, after ruling out other disorders that may cause alveolar hypoventilation. OHS prevalence has been estimated to be ∼0.4% of the adult population. OHS is typically diagnosed during an episode of acute-on-chronic hypercapnic respiratory failure or when symptoms lead to pulmonary or sleep consultation in stable conditions. The diagnosis is firmly established after arterial blood gases and a sleep study. The presence of daytime hypercapnia is explained by several co-existing mechanisms such as obesity-related changes in the respiratory system, alterations in respiratory drive and breathing abnormalities during sleep. The most frequent comorbidities are metabolic and cardiovascular, mainly heart failure, coronary disease and pulmonary hypertension. Both continuous positive airway pressure (CPAP) and noninvasive ventilation (NIV) improve clinical symptoms, quality of life, gas exchange, and sleep disordered breathing. CPAP is considered the first-line treatment modality for OHS phenotype with concomitant severe obstructive sleep apnoea, whereas NIV is preferred in the minority of OHS patients with hypoventilation during sleep with no or milder forms of obstructive sleep apnoea (approximately <30% of OHS patients). Acute-on-chronic hypercapnic respiratory failure is habitually treated with NIV. Appropriate management of comorbidities including medications and rehabilitation programmes are key issues for improving prognosis.
Obstructive sleep apnea (OSA) is a prevalent disease associated with significant morbidity and high healthcare costs. Information and communication technology could offer cost-effective management ...options.
To evaluate an out-of-hospital Virtual Sleep Unit (VSU) based on telemedicine to manage all patients with suspected OSA, including those with and without continuous positive airway pressure (CPAP) therapy.
This was an open randomized controlled trial. Patients with suspected OSA were randomized to hospital routine (HR) or VSU groups to compare the clinical improvement and cost-effectiveness in a non-inferiority analysis. Improvement was assessed by changes in the Quebec Sleep Questionnaire (QSQ), EuroQol (EQ-5D and EQ-VAS), and Epworth Sleepiness Scale (ESS). The follow-up was 3 months. Cost-effectiveness was assessed by a Bayesian analysis based on quality-adjusted life-years (QALYs).
The HR group (n: 92; 78% OSA, 57% CPAP) compared with the VSU group (n: 94; 83% OSA, 43% CPAP) showed: CPAP compliance was similar in both groups, the QSQ social interactions domain improved significantly more in the HR group whereas the EQ-VAS improved more in the VSU group. Total and OSA-related costs were lower in the VSU group than the HR. The Bayesian cost-effectiveness analysis showed that VSU was cost-effective for a wide range of willingness to pay for QALYs.
The VSU offered a cost-effective means of improving QALYs than HR. However, the assessment of its clinical improvement was influenced by the choice of the questionnaire; hence, additional measurements of clinical improvement are needed. Our findings indicate that VSU could help with the management of many patients, irrespective of CPAP use.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
IMPORTANCE More than 70% of patients with resistant hypertension have obstructive sleep apnea (OSA). However, there is little evidence about the effect of continuous positive airway pressure (CPAP) ...treatment on blood pressure in patients with resistant hypertension. OBJECTIVE To assess the effect of CPAP treatment on blood pressure values and nocturnal blood pressure patterns in patients with resistant hypertension and OSA. DESIGN, SETTING, AND PARTICIPANTS Open-label, randomized, multicenter clinical trial of parallel groups with blinded end point design conducted in 24 teaching hospitals in Spain involving 194 patients with resistant hypertension and an apnea-hypopnea index (AHI) of 15 or higher. Data were collected from June 2009 to October 2011. INTERVENTIONS CPAP or no therapy while maintaining usual blood pressure control medication. MAIN OUTCOMES AND MEASURES The primary end point was the change in 24-hour mean blood pressure after 12 weeks. Secondary end points included changes in other blood pressure values and changes in nocturnal blood pressure patterns. Both intention-to-treat (ITT) and per-protocol analyses were performed. RESULTS A total of 194 patients were randomly assigned to receive CPAP (n = 98) or no CPAP (control; n = 96). The mean AHI was 40.4 (SD, 18.9) and an average of 3.8 antihypertensive drugs were taken per patient. Baseline 24-hour mean blood pressure was 103.4 mm Hg; systolic blood pressure (SBP), 144.2 mm Hg; and diastolic blood pressure (DBP), 83 mm Hg. At baseline, 25.8% of patients displayed a dipper pattern (a decrease of at least 10% in the average nighttime blood pressure compared with the average daytime blood pressure). The percentage of patients using CPAP for 4 or more hours per day was 72.4%. When the changes in blood pressure over the study period were compared between groups by ITT, the CPAP group achieved a greater decrease in 24-hour mean blood pressure (3.1 mm Hg 95% CI, 0.6 to 5.6; P = .02) and 24-hour DBP (3.2 mm Hg 95% CI, 1.0 to 5.4; P = .005), but not in 24-hour SBP (3.1 mm Hg 95% CI, −0.6 to 6.7; P = .10) compared with the control group. Moreover, the percentage of patients displaying a nocturnal blood pressure dipper pattern at the 12-week follow-up was greater in the CPAP group than in the control group (35.9% vs 21.6%; adjusted odds ratio OR, 2.4 95% CI, 1.2 to 5.1; P = .02). There was a significant positive correlation between hours of CPAP use and the decrease in 24-hour mean blood pressure (r = 0.29, P = .006), SBP (r = 0.25; P = .02), and DBP (r = 0.30, P = .005). CONCLUSIONS AND RELEVANCE Among patients with OSA and resistant hypertension, CPAP treatment for 12 weeks compared with control resulted in a decrease in 24-hour mean and diastolic blood pressure and an improvement in the nocturnal blood pressure pattern. Further research is warranted to assess longer-term health outcomes. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00616265
The incidence of obesity hypoventilation syndrome (OHS) may be increasing in parallel with the present obesity epidemic. Despite extensive noninvasive ventilation (NIV) and continuous positive airway ...pressure (CPAP) use in patients with OHS, information regarding efficacy is limited.
We performed a large, multicenter randomized controlled study to determine the comparative efficacy of NIV, CPAP, and lifestyle modification (control group) using daytime PaCO2 as the main outcome measure.
Sequentially screened patients with OHS with severe sleep apnea were randomized into the above-mentioned groups for a 2-month follow up. Arterial blood gas parameters, clinical symptoms, health-related quality-of-life assessments, polysomnography, spirometry, 6-minute-walk distance, dropouts, compliance, and side effects were evaluated. Statistical analysis was performed using intention-to-treat analysis, although adjustments for CPAP and NIV compliance were also analyzed.
In total, 351 patients were selected, and 221 were randomized. NIV yielded the greatest improvement in PaCO2 and bicarbonate, with significant differences relative to the control group but not relative to the CPAP group. In the CPAP group, PaCO2 improvement was significantly different than in the control group only after CPAP compliance adjustment. Additionally, clinical symptoms and polysomnographic parameters improved similarly with NIV and CPAP relative to the control. However, some health-related quality-of-life assessments, the spirometry, and 6-minute-walk distance results improved more with NIV than with CPAP. Dropouts were similar between groups, and compliance and secondary effects were similar between NIV and CPAP.
NIV and CPAP were more effective than lifestyle modification in improving clinical symptoms and polysomnographic parameters, although NIV yielded better respiratory functional improvements than did CPAP. Long-term studies must demonstrate whether this functional improvement has relevant implications. Clinical trial registered with www.clinicaltrials.gov (NCT01405976).
CONTEXT Continuous positive airway pressure (CPAP) is the first-line treatment for patients with symptomatic obstructive sleep apnea (OSA). However, its indication for all patients with ...sleep-disordered breathing, regardless of daytime symptoms, is unclear. OBJECTIVE To evaluate the effect of CPAP treatment on the incidence of hypertension or cardiovascular events in a cohort of nonsleepy patients with OSA. DESIGN, SETTING, AND PATIENTS Multicenter, parallel-group, randomized controlled trial in 14 teaching hospitals in Spain. Between May 2004 and May 2006, 725 consecutive patients were enrolled who had an apnea-hypopnea index of 20 h−1 or greater and an Epworth Sleepiness Scale score of 10 or less (scores range from 0-24, with values <10 suggesting no daytime sleepiness). Exclusion criteria were previous cardiovascular event, physical or psychological incapacity, chronic disease, or drug or alcohol addiction. Follow-up ended in May 2009. INTERVENTION Patients were allocated to receive CPAP treatment or no active intervention. All participants received dietary counseling and sleep hygiene advice. MAIN OUTCOME MEASURES Incidence of either systemic hypertension (taking antihypertensive medication or blood pressure greater than 140/90 mm Hg) or cardiovascular event (nonfatal myocardial infarction, nonfatal stroke, transient ischemic attack, hospitalization for unstable angina or arrhythmia, heart failure, or cardiovascular death). RESULTS Seven hundred twenty-three patients underwent follow-up for a median of 4 (interquartile range, 2.7-4.4) years (1 patient from each group did not receive allocated treatment); 357 in the CPAP group and 366 in the control group were included in the analysis. In the CPAP group there were 68 patients with new hypertension and 28 cardiovascular events (17 unstable angina or arrhythmia, 3 nonfatal stroke, 3 heart failure, 2 nonfatal myocardial infarction, 2 transient ischemic attack, 1 cardiovascular death). In the control group there were 79 patients with new hypertension and 31 cardiovascular events (11 unstable angina or arrhythmia, 8 nonfatal myocardial infarction, 5 transient ischemic attack, 5 heart failure, 2 nonfatal stroke). The hypertension or cardiovascular event incidence density rate was 9.20 per 100 person-years (95% CI, 7.36-11.04) in the CPAP group and 11.02 per 100 person-years (95% CI, 8.96-13.08) in the control group. The incidence density ratio was 0.83 (95% CI, 0.63-1.1; P = .20). CONCLUSIONS In patients with OSA without daytime sleepiness, the prescription of CPAP compared with usual care did not result in a statistically significant reduction in the incidence of hypertension or cardiovascular events. However, the study may have had limited power to detect a significant difference. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00127348
In this case, omeprazole may convert to its active form in the acidic environment of asthmatic lung airways,8 facilitating its inhibitory activity. ...the presence of inflammatory cells, including ...eosinophils, was significantly reduced in bronchoalveolar lavage fluid (Fig 2, D) and lung sections (see this article's Fig E1 in the Online Repository at www.jacionline.org) from omeprazole-treated animals.
OHS patients have higher morbidity and mortality rates. Exosomes are released into the bloodstream and play a role in tumor growth and metastasis. Twenty-four OHS patients (13 male and 11 female) ...were evaluated at diagnosis (Pre), and after CPAP treatment (T3, T12 and T24 months). Plasma exosomes were applied into naïve NCI-H23 lung cancer cells. Exosomes from OHS patients enhance PMI of human lung cancer cells, and these effects are at least partially reversible with adherent CPAP treatment. Our findings suggest that OHS-induced changes in exosome cargo promote cancer aggressiveness in NCI-H23 lung adenocarcinoma and exhibit OHS treatment-related reversibility.
•OHS patients have higher morbidity and mortality rates.•Exosomes are released into the bloodstream and play a role in tumor growth and metastasis.•Twenty-four OHS patients (13 male and 11 female) were evaluated at diagnosis (Pre), and after CPAP treatment (T3, T12 and T24 months). Plasma exosomes were applied into naïve NCI-H23 lung cancer cells.•We found that exosomes from OHS patients enhance PMI of human lung cancer cells, and these effects are at least partially reversible with adherent CPAP treatment.•Our findings suggest that OHS-induced changes in exosome cargo promote cancer aggressiveness in NCI-H23 lung adenocarcinoma and exhibit OHS treatment-related reversibility.
Medium and long-term trials comparing continuous positive airway pressure (CPAP) with noninvasive ventilation in patients with obesity hypoventilation syndrome have shown no differences in outcomes. ...However, it remains unclear whether CPAP therapy should be prescribed if significant hypoxemia persists during CPAP titration, despite optimization of upper airway obstructive events or if maximum CPAP pressure is reached. We aimed to examine the effects of 6 weeks of home CPAP therapy on gas exchange in patients with obesity hypoventilation syndrome who failed CPAP titration due to persistent hypoxemia.
This case series is a substudy of a randomized-controlled trial evaluating efficacy of 3 different PAP modalities in obesity hypoventilation syndrome. Patients randomized to CPAP who failed titration and were prescribed CPAP are included. CPAP failure was defined as spending more than 20% of total sleep time with oxygen saturation below 90% despite adequate resolution of apneas and hypopneas. Follow-up data included in-laboratory polysomnogram on prescribed CPAP after 6 weeks of home CPAP therapy.
Three of seven participants (43%) randomized to CPAP failed CPAP titration. All were morbidly obese, had severe OSA (apnea-hypopnea index > 90 events/h) and severe sleep hypoxemia (percentage of total sleep time with oxygen saturation < 90% T90 = 60-89%). Hypoxemia (T90: 43-67%, T80: 0-31%, and T70: 0-11%) and hypercapnia (transcutaneous pressure of CO₂ levels > 50 mm Hg) persisted during CPAP titration polysomnogram. The final polysomnogram after 6 weeks of adherent home CPAP therapy showed effective control of obstructive sleep apnea. Hypoventilation and hypoxemia severity decreased significantly in all 3 participants.
Our data suggest that CPAP titration failure does not equal CPAP treatment failure.
Registry: ClinicalTrials.gov; Name: AVAPS-AE Efficacy Study; URL: https://clinicaltrials.gov/ct2/show/NCT01368614; Identifier: NCT01368614.
Home respiratory polygraphy may be a simpler alternative to in-laboratory polysomnography for the management of more symptomatic patients with obstructive sleep apnea, but its effectiveness has not ...been evaluated across a broad clinical spectrum.
To compare the long-term effectiveness (6 mo) of home respiratory polygraphy and polysomnography management protocols in patients with intermediate-to-high sleep apnea suspicion (most patients requiring a sleep study).
A multicentric, noninferiority, randomized controlled trial with two open parallel arms and a cost-effectiveness analysis was performed in 12 tertiary hospitals in Spain. Sequentially screened patients with sleep apnea suspicion were randomized to respiratory polygraphy or polysomnography protocols. Moreover, both arms received standardized therapeutic decision-making, continuous positive airway pressure (CPAP) treatment or a healthy habit assessment, auto-CPAP titration (for CPAP indication), health-related quality-of-life questionnaires, 24-hour blood pressure monitoring, and polysomnography at the end of follow-up. The main outcome was the Epworth Sleepiness Scale measurement. The noninferiority criterion was -2 points on the Epworth scale.
In total, 430 patients were randomized. The respiratory polygraphy protocol was noninferior to the polysomnography protocol based on the Epworth scale. Quality of life, blood pressure, and polysomnography were similar between protocols. Respiratory polygraphy was the most cost-effective protocol, with a lower per-patient cost of 416.7€.
Home respiratory polygraphy management is similarly effective to polysomnography, with a substantially lower cost. Therefore, polysomnography is not necessary for most patients with suspected sleep apnea. This finding could change established clinical practice, with a clear economic benefit. Clinical trial registered with www.clinicaltrials.gov (NCT 01752556).
The optimal interface for the delivery of home non-invasive ventilation (NIV) to treat chronic respiratory failure has not yet been determined. The aim of this individual participant data (IPD) ...meta-analysis was to compare the effect of nasal and oronasal masks on treatment efficacy and adherence in patients with COPD and obesity hypoventilation syndrome (OHS).
We searched Medline and Cochrane Central Register of Controlled Trials for prospective randomised controlled trials (RCTs) of at least 1 month's duration, published between January 1994 and April 2019, that assessed NIV efficacy in patients with OHS and COPD. The main outcomes were diurnal PaCO
, PaO
and NIV adherence (PROSPERO CRD42019132398).
Of 1576 articles identified, 34 RCTs met the inclusion criteria and IPD were obtained for 18. Ten RCTs were excluded because only one type of mask was used, or mask data were missing. Data from 8 RCTs, including 290 IPD, underwent meta-analysis. Oronasal masks were used in 86% of cases. There were no differences between oronasal and nasal masks for PaCO
(0.61 mm Hg (95% CI -2.15 to 3.38); p=0.68), PaO
(-0.00 mm Hg (95% CI -4.59 to 4.58); p=1) or NIV adherence (0·29 hour/day (95% CI -0.74 to 1.32); p=0.58). There was no interaction between the underlying pathology and the effect of mask type on any outcome.
Oronasal masks are the most used interface for the delivery of home NIV in patients with OHS and COPD; however, there is no difference in the efficacy or tolerance of oronasal or nasal masks.