Preclinical studies have demonstrated that high mechanical index (MI) impulses from a diagnostic ultrasound transducer during an intravenous microbubble infusion (sonothrombolysis) can restore ...epicardial and microvascular flow in acute ST-segment elevation myocardial infarction (STEMI).
This study tested the clinical effectiveness of sonothrombolysis in patients with STEMI.
Patients with their first STEMI were prospectively randomized to either diagnostic ultrasound–guided high MI impulses during an intravenous Definity (Lantheus Medical Imaging, North Billerica, Massachusetts) infusion before, and following, emergent percutaneous coronary intervention (PCI), or to a control group that received PCI only (n = 50 in each group). A reference first STEMI group (n = 203) who arrived outside the randomization window was also analyzed. Angiographic recanalization before PCI, ST-segment resolution, infarct size by magnetic resonance imaging, and systolic function (LVEF) at 6 months were compared.
ST-segment resolution occurred in 16 (32%) high MI PCI versus 2 (4%) PCI-only patients before PCI, and angiographic recanalization was 48% in high MI/PCI versus 20% in PCI only and 21% in the reference group (p < 0.001). Infarct size was reduced (29 ± 22 g high MI/PCI vs. 40 ± 20 g PCI only; p = 0.026). LVEF was not different between groups before treatment (44 ± 11% vs. 43 ± 10%), but increased immediately after PCI in the high MI/PCI group (p = 0.03), and remained higher at 6 months (p = 0.015). Need for implantable defibrillator (LVEF ≤30%) was reduced in the high MI/PCI group (5% vs. 18% PCI only; p = 0.045).
Sonothrombolysis added to PCI improves recanalization rates and reduces infarct size, resulting in sustained improvements in systolic function after STEMI. (Therapeutic Use of Ultrasound in Acute Coronary Artery Disease; NCT02410330).
Display omitted
In this trial, the authors have discovered that intermittent HMI ultrasound impulses with a standard diagnostic system (i.e., 33, Philips Healthcare, Bothel, Washington) during a lipid encapsulated ...microbubble infusion before granulocyte colony-stimulating factor (GCSF) injection resulted in greater improvements in left ventricular ejection fraction following acute anterior myocardial infarction.
Acute kidney injury (AKI) is frequently observed after transcatheter aortic valve implantation (TAVI). Of note, it is associated with a threefold increase in all-cause and cardiac death. We propose a ...new non-contrast strategy for evaluating and performing the TAVI procedure that can be especially valuable for patients with aortic stenosis (AS) and chronic kidney disease (CKD) to prevent AKI.
Patients with severe symptomatic AS and CKD stage ≥3a were evaluated for TAVI using four non-contrast imaging modalities for procedural planning: transesophageal echocardiogram (TEE), cardiac magnetic resonance, multidetector computed tomography (MDCT), and aortoiliac CO
angiography. Patients underwent transfemoral (TF) TAVI using the self-expandable Evolut R/Pro, and the procedures were guided by fluoroscopy and TEE. Contrast MDCT and contrast injection at certain checkpoints during the procedure were used in a blinded fashion to guarantee patient safety.
A total of 25 patients underwent TF-TAVI with the zero-contrast technique. The mean age was 79.9 ± 6.1 years, 72% in NYHA class III/IV, with a mean STS-PROM of 3.0% ± 1.5%, and creatinine clearance of 49 ± 7 ml/min. The self-expandable Evolut R and Pro were implanted in 80% and 20% of patients, respectively. In 36% of the cases, the transcatheter heart valve (THV) chosen was one size larger than the one by contrast MDCT, but none of these cases presented adverse events. Device success and the combined safety endpoint (at 30 days) both achieved 92%. Pacemaker implantation was needed in 17%.
This pilot study demonstrated that the zero-contrast technique for procedural planning and THV implantation was feasible and safe and might become the preferable strategy for a significant population of CKD patients undergoing TAVR. Future studies with a larger number of patients are still needed to confirm such interesting findings.
We sought to determine the prognostic value of qualitative and quantitative analysis obtained by real-time myocardial perfusion echocardiography (RTMPE) in patients with known or suspected coronary ...artery disease (CAD).
Quantification of myocardial blood flow reserve (MBFR) in patients with CAD using RTMPE has been demonstrated to further improve accuracy over the analysis of wall motion (WM) and qualitative analysis of myocardial perfusion (QMP).
From March 2003 to December 2008, we prospectively studied 168 patients with normal left ventricular function (LVF) who underwent dobutamine stress RTMPE. The replenishment velocity reserve (β) and MBFR were derived from RTMPE. Acute coronary events were: cardiac death, myocardial infarction and unstable angina with need for urgent coronary revascularization.
During a median follow-up of 34 months (5 days to 6.9 years), 17 acute coronary events occurred. Abnormal β reserve in ≥2 coronary territories was the only independent predictor of events hazard ratio (HR) = 21, 95% CI = 4.5-99; p<0.001). Both, abnormal β reserve and MBFR added significant incremental value in predicting events over qualitative analysis of WM and MP (χ2 = 6.6 and χ2 = 24.6, respectively; p = 0.001 and χ2 = 6.6 and χ2 = 15.5, respectively; p = 0.012, respectively). When coronary angiographic data was added to the multivariate analysis model, β reserve remained the only predictor of events with HR of 21.0 (95% CI = 4.5-99); p<0.001.
Quantitative dobutamine stress RTMPE provides incremental prognostic information over clinical variables, qualitative analysis of WM and MP, and coronary angiography in predicting acute coronary events.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Acute cellular rejection (ACR) is a major complication after heart transplantation. Endomyocardial biopsy (EMB) remains the gold standard for its diagnosis, but it has concerning complications. We ...evaluated the usefulness of speckle tracking echocardiography (STE) and biomarkers for detecting ACR after heart transplantation.
We prospectively studied 60 transplant patients with normal left and right ventricular systolic function who underwent EMB for surveillance 6 months after transplantation. Sixty age- and sex-matched healthy individuals constituted the control group. Conventional echocardiographic parameters, left ventricular global longitudinal, radial and circumferential strain (LV-GLS, LV-GRS and LV-GCS, respectively), left ventricular systolic twist (LV-twist) and right ventricular free wall longitudinal strain (RV-FWLS) were analyzed just before the procedure. We also measured biomarkers at the same moment.
Among the 60 studied patients, 17 (28%) had severe ACR (grade ≥ 2R), and 43 (72%) had no significant ACR (grade 0 - 1R). The absolute values of LV-GLS, LV-twist and RV-FWLS were lower in transplant patients with ACR degree ≥ 2 R than in those without ACR (12.5% ± 2.9% vs 14.8% ± 2.3%, p=0.002; 13.9° ± 4.8° vs 17.1° ± 3.2°, p=0.048; 16.6% ± 2.9% vs 21.4%± 3.2%, p < 0.001; respectively), while no differences were observed between the LV-GRS or LV-GCS. All of these parameters were lower in the transplant group without ACR than in the nontransplant control group, except for the LV-twist. Cardiac troponin I levels were significantly higher in patients with significant ACR than in patients without significant ACR 0.19 ng/mL (0.09-1.31) vs 0.05 ng/mL (0.01-0.18), p=0.007. The combination of troponin with LV-GLS, RV-FWLS and LV-Twist had an area under curve for the detection of ACR of 0.80 (0.68-0.92), 0.89 (0.81-0.93) and 0.79 (0.66-0.92), respectively.
Heart transplant patients have altered left ventricular dynamics compared with control individuals. The combination of troponin with strain parameters had higher accuracy for the detection of ACR than the isolated variables and this association might select patients with a higher risk for ACR who will benefit from an EMB procedure in the first year after heart transplantation.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The aim of the present study is to assess multimodality imaging findings according to systemic biomarkers, high-sensitivity troponin I (hsTnI) and B-type natriuretic peptide (BNP) levels, in ...low-flow, low-gradient aortic stenosis (LFLG-AS).
Elevated levels of BNP and hsTnI have been related with poor prognosis in patients with LFLG-AS.
Prospective study with LFLG-AS patients that underwent hsTnI, BNP, coronary angiography, cardiac magnetic resonance (CMR) with T1 mapping, echocardiogram and dobutamine stress echocardiogram. Patients were divided into 3 groups according to BNP and hsTnI levels: Group 1 (
= 17) when BNP and hsTnI levels were below median BNP < 1.98 fold upper reference limit (URL) and hsTnI < 1.8 fold URL; Group 2 (
= 14) when BNP or hsTnI were higher than median; and Group 3 (
= 18) when both hsTnI and BNP were higher than median.
49 patients included in 3 groups. Clinical characteristics (including risk scores) were similar among groups. Group 3 patients had lower valvuloarterial impedance (
= 0.03) and lower left ventricular ejection fraction (
= 0.02) by echocardiogram. CMR identified a progressive increase of right and left ventricular chamber from Group 1 to Group 3, and worsening of left ventricular ejection fraction (EF) (40 31-47 vs. 32 29-41 vs. 26 19-33%;
< 0.01) and right ventricular EF (62 53-69 vs. 51 35-63 vs. 30 24-46%;
< 0.01). Besides, there was a marked increase in myocardial fibrosis assessed by extracellular volume fraction (ECV) (28.4 24.8-30.7 vs. 28.2 26.9-34.5 vs. 31.8 28.9-35.5%;
= 0.03) and indexed ECV (iECV) (28.7 21.2-39.1 vs. 28.8 25.4-39.9 vs. 44.2 36.4-51.2 ml/m
, respectively;
< 0.01) from Group 1 to Group 3.
Higher levels of BNP and hsTnI in LFLG-AS patients are associated with worse multi-modality evidence of cardiac remodeling and fibrosis.
Estudo da Mecânica Cardíaca pelo Speckle Tracking Abduch, Maria Cristina Donadio; Alencar, Adriano Mesquita; Mathias Jr, Wilson ...
Arquivos brasileiros de cardiologia,
04/2014, Letnik:
102, Številka:
4
Journal Article
Recenzirano
Odprti dostop
Speckles, ou marcadores naturais do miocárdio, originam se da interferência construtiva e destrutiva do feixe de ultrassom que incide sobre os tecidos, podem fornecer um diagnóstico precoce das ...alterações miocárdicas e atuar na predição de certos eventos cardíacos. Devido à sua relativa estabilidade temporal, os speckles podem ser rastreados durante o ciclo cardíaco por software dedicados, promovendo a análise da função sistólica e diastólica. São identificados tanto pela escala de cinza da ecocardiografia 2D convencional quanto pela ecocardiografia 3D, sendo independentes do ângulo de incidência do ultrassom, permitindo assim a avaliação da mecânica cardíaca nos três planos espaciais: longitudinal, circunferencial e radial. O objetivo do presente artigo é discutir o papel e o significado da deformação cardíaca obtida por meio do speckle tracking durante a avaliação da fisiologia cardíaca, e discutir as aplicações clínicas desta tecnologia ecocardiográfica inovadora.
Background
Cardiac shockwave therapy (CSWT) is a new potential option for the treatment of patients with chronic coronary disease and refractory angina (RA). We aimed to study the effects of CSWT on ...left ventricular myocardial perfusion and mechanics in patients with RA.
Method
We prospectively studied 19 patients who underwent CSWT. Left ventricular mechanics were evaluated by speckle tracking echocardiography (STE), and myocardial perfusion by single‐photon emission computed tomography, using stress/rest–Technetium‐99 m Sestamibi, for determination of summed stress score (SSS). Canadian Cardiac Society (CCS), New York Heart Association (NYHA), and quality of life by Seattle Angina Questionnaire (SAQ) were assessed at baseline and 6 months after therapy.
Results
CSWT therapy was applied without major side effects. At baseline, 18 patients (94.7%) had CCS class III or IV, and after CSWT there was reduction to 3 (15.8%), P = .0001, associated with improvement in SAQ (38.5%; P < .001). Thirteen (68.4%) had class NYHA III or IV before treatment, with significant reduction to 7 (36.8%); P = .014. No change was observed in the global SSS from baseline to 6‐month follow‐up (15.33 ± 8.60 vs 16.60 ± 8.06; P = .157). However, there was a significant reduction in the average SSS of the treated ischemic segments (2.1 ± 0.87 pre vs 1.6 ± 1.19 post CSWT; P = .024). Global longitudinal strain by STE remained unaltered (‐13.03 ± 8.96 pre vs ‐15.88 ± 3.43 6‐month post CSWT; P = .256).
Conclusion
CSWT is a safe procedure for the treatment of patients with RA that results in better quality of life, improvement in myocardial perfusion of the treated segments with preservation of left ventricular mechanics.
Abstract Background Pre-clinical trials have demonstrated that, during intravenous microbubble infusion, high mechanical index (HMI) impulses from a diagnostic ultrasound (DUS) transducer might ...restore epicardial and microvascular flow in acute ST-segment elevation myocardial infarction (STEMI). Objectives The purpose of this study was to test the safety and efficacy of this adjunctive approach in humans. Methods From May 2014 through September 2015, patients arriving with their first STEMI were randomized to either DUS intermittent HMI impulses (n = 20) just prior to emergent percutaneous coronary intervention (PCI) and for an additional 30 min post-PCI (HMI + PCI), or low mechanical index (LMI) imaging only (n = 10) for perfusion assessments before and after PCI (LMI + PCI). All studies were conducted during an intravenous perflutren lipid microsphere infusion. A control reference group (n = 70) arrived outside of the time window of ultrasound availability and received emergent PCI alone (PCI only). Initial epicardial recanalization rates prior to emergent PCI and improvements in microvascular flow were compared between ultrasound-treated groups. Results Median door-to-dilation times were 82 ± 26 min in the LMI + PCI group, 72 ± 15 min in the HMI + PCI group, and 103 ± 42 min in the PCI-only group (p = NS). Angiographic recanalization prior to PCI was seen in 12 of 20 HMI + PCI patients (60%) compared with 10% of LMI + PCI and 23% of PCI-only patients (p = 0.002). There were no differences in microvascular obstructed segments prior to treatment, but there were significantly smaller proportions of obstructed segments in the HMI + PCI group at 1 month (p = 0.001) and significant improvements in left ventricular ejection fraction (p < 0.005). Conclusions HMI impulses from a diagnostic transducer, combined with a commercial microbubble infusion, can prevent microvascular obstruction and improve functional outcome when added to the contemporary PCI management of acute STEMI. (Therapeutic Use of Ultrasound in Acute Coronary Artery Disease; NCT02410330 )