In the last decade, cryogenic bolometers have provided increasingly improved resolution and sensitivity in particle and radiation detectors. Thermal particle detectors have proven their outstanding ...capabilities in different fields of fundamental physics, especially in rare event detection. Cryogenic incoherent detector arrays designed to detect millimeter-wave photons have helped enable precision measurements of anisotropies in the cosmic microwave background (CMB), providing a unique probe of early universe physics and helping to constrain parameters of particle physics such as the sum of the neutrino masses. We review the latest achievements of cryogenic particle detectors for direct detection searches for dark matter and double-
decay, as well as for CMB measurements, and we discuss expected improvements aiming to increase the sensitivities of these experiments. An important challenge is the large-scale implementation of arrays of detectors such as transition edge sensors, especially in CMB polarization experiments. We describe the challenges of scaling up to these larger arrays, including fabrication throughput and development of new multiplexing electronics.
Superconducting detector arrays have become the standard technology for the current generation of millimeter-wave and submm-wave astronomical instruments on individual (single dish) telescopes. ...Superconducting heterodyne arrays are used for spectroscopic surveys and direct detector arrays are used for photometric imaging and low resolution spectroscopy. Most of these direct detector arrays consist of bolometers with superconducting thermometers called Transition Edge Sensors (TES) and are read out with multiplexed superconducting quantum interference device (SQUID) current amplifiers. Another superconducting detector technology called Kinetic Inductance Detectors (KIDs) is starting to be used in new astronomical instruments as well. This review describes the properties of these two types of detectors and the prospects for future development of both types of technologies toward larger pixel counts and more capable instruments.
Aims. Lumped-element kinetic inductance detectors (LEKIDs) are an attractive technology for millimeter-wave observations that require large arrays of extremely low-noise detectors. We designed, ...fabricated and characterized 64-element (128 LEKID) arrays of horn-coupled, dual-polarization LEKIDs optimized for ground-based CMB polarimetry. Our devices are sensitive to two orthogonal polarizations in a single spectral band centered on 150 GHz with Δν∕ν = 0.2. The 65 × 65 mm square arrays are designed to be tiled into the focal plane of an optical system. We demonstrate the viability of these dual-polarization LEKIDs with laboratory measurements. Methods. The LEKID modules are tested with an FPGA-based readout system in a sub-kelvin cryostat that uses a two-stage adiabatic demagnetization refrigerator. The devices are characterized using a blackbody and a millimeter-wave source. The polarization properties are measured with a cryogenic stepped half-wave plate. We measure the resonator parameters and the detector sensitivity, noise spectrum, dynamic range, and polarization response. Results. The resonators have internal quality factors approaching 1 × 106. The detectors have uniform response between orthogonal polarizations and a large dynamic range. The detectors are photon-noise limited above 1 pW of absorbed power. The noise-equivalent temperatures under a 3.4 K blackbody load are <100 μK √s ${<} 100~\mu\mathrm{K}\sqrt{\mathrm{s}}$ <100μKs . The polarization fractions of detectors sensitive to orthogonal polarizations are >80%. The entire array is multiplexed on a single readout line, demonstrating a multiplexing factor of 128. The array and readout meet the requirements for 4 arrays to be read out simultaneously for a multiplexing factor of 512. Conclusions. This laboratory study demonstrates the first dual-polarization LEKID array optimized specifically for CMB polarimetry and shows the readiness of the detectors for on-sky observations.
The Neel IRAM KIDs Array (NIKA) is a fully integrated measurement system based on kinetic inductance detectors (KIDs) currently being developed for millimeter wave astronomy. The instrument includes ...dual-band optics allowing simultaneous imaging at 150 GHz and 220 GHz. The imaging sensors consist of two spatially separated arrays of KIDs. The first array, mounted on the 150 GHz branch, is composed of 144 lumped-element KIDs. The second array (220 GHz) consists of 256 antenna-coupled KIDs. Each of the arrays is sensitive to a single polarization; the band splitting is achieved by using a grid polarizer. The optics and sensors are mounted in a custom dilution cryostat, with an operating temperature of ~70 mK. Electronic readout is realized using frequency multiplexing and a transmission line geometry consisting of a coaxial cable connected in series with the sensor array and a low-noise 4 K amplifier. The dual-band NIKA was successfully tested in 2010 October at the Institute for Millimetric Radio Astronomy (IRAM) 30 m telescope at Pico Veleta, Spain, performing in-line with laboratory predictions. An optical NEP was then calculated to be around 2 X 10--16 W Hz--1/2 (at 1 Hz) while under a background loading of approximately 4 pW pixel--1. This improvement in comparison with a preliminary run (2009) verifies that NIKA is approaching the target sensitivity for photon-noise limited ground-based detectors. Taking advantage of the larger arrays and increased sensitivity, a number of scientifically relevant faint and extended objects were then imaged including the Galactic Center SgrB2 (FIR1), the radio galaxy Cygnus A, and the NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the 150 GHz and 220 GHz atmospheric windows.
The complete characterization of the pressure profile of high-redshift galaxy clusters, from their core to their outskirts, is a major issue for the study of the formation of large-scale structures. ...It is essential to constrain a potential redshift evolution of both the slope and scatter of the mass-observable scaling relations used in cosmology studies based on cluster statistics. In this paper, we present the first thermal Sunyaev–Zel’dovich (tSZ) mapping of a cluster from the sample of the New IRAM Kids Arrays (NIKA2) SZ large program that aims at constraining the redshift evolution of cluster pressure profiles and the tSZ-mass scaling relation. We observed the galaxy cluster PSZ2 G144.83+25.11 at redshift z = 0.58 with the NIKA2 camera, a dual-band (150 and 260 GHz) instrument operated at the Institut de Radioastronomie Millimtrique (IRAM) 30-m telescope. We identify a thermal pressure excess in the south-west region of PSZ2 G144.83+25.11 and a high-redshift sub-millimeter point source that affect the intracluster medium (ICM) morphology of the cluster. The NIKA2 data are used jointly with tSZ data acquired by the Multiplexed SQUID/TES Array at Ninety Gigahertz (MUSTANG), Bolocam, and Planck experiments in order to non-parametrically set the best constraints on the electronic pressure distribution from the cluster core (R ~ 0.02R500) to its outskirts (R ~ 3R500). We investigate the impact of the over-pressure region on the shape of the pressure profile and on the constraints on the integrated Compton parameter Y500. A hydrostatic mass analysis is also performed by combining the tSZ-constrained pressure profile with the deprojected electronic density profile from XMM-Newton. This allows us to conclude that the estimates of Y500 and M500 obtained from the analysis with and without masking the disturbed ICM region differ by 65% and 79%, respectively. This work highlights that NIKA2 will have a crucial impact on the characterization of the scatter of the Y500−M500 scaling relation due to its high potential to constrain the thermodynamic and morphological properties of the ICM when used in synergy with X-ray observations of similar angular resolution. This study also presents the typical products that will be delivered to the community for all clusters included in the NIKA2 tSZ Large Program.
Superconducting nanowires are widely used as sensitive single photon detectors with wide spectral coverage and high timing resolution. We describe a demonstration of an array of dc-biased ...superconducting nanowire single photon detectors read out with a microwave multiplexing circuit. In this design, each individual nanowire is part of a resonant LC circuit where the inductance is dominated by the kinetic inductance of the nanowire. The circuit also contains two parallel plate capacitors, one of them is in parallel with the inductor and the other is coupled to a microwave transmission line that carries the signals to a cryogenic low-noise amplifier. All of the nanowires are connected via resistors to a single dc bias line that enables the nanowires to be current biased close to their critical current. When a photon hits a nanowire, it creates a normal hotspot that produces a voltage pulse across the LC circuit. This pulse rings down at the resonant frequency of the LC circuit over a time period that is fixed by the quality factor. We present measurements of an array of these devices and an evaluation of their performance in terms of frequency and time response.
The AzTEC mm-wavelength camera Wilson, G. W.; Austermann, J. E.; Perera, T. A. ...
Monthly notices of the Royal Astronomical Society,
20/May , Letnik:
386, Številka:
2
Journal Article
Recenzirano
Odprti dostop
AzTEC is a mm-wavelength bolometric camera utilizing 144 silicon nitride micromesh detectors. Here, we describe the AzTEC instrument architecture and its use as an astronomical instrument. We report ...on several performance metrics measured during a three-month observing campaign at the James Clerk Maxwell Telescope and conclude with our plans for AzTEC as a facility instrument on the Large Millimetre Telescope.