Predicting patients at risk of a poor outcome would be useful in patient selection for total knee arthroplasty (TKA). Existing models to predict outcome have seen limited functional implementation. ...This study aims to validate a model and shared decision-making tool for both clinical utility and predictive accuracy.
A Bayesian belief network statistical model was developed using data from the Osteoarthritis Initiative. A consecutive series of consultations for osteoarthritis before and after introduction of the tool was used to evaluate the clinical impact of the tool. A data audit of postoperative outcomes of TKA patients exposed to the tool was used to evaluate the accuracy of predictions.
The tool changed consultation outcomes and identified patients at risk of limited improvement. After introduction of the tool, patients booked for surgery reported worse Knee Osteoarthritis and Injury Outcome Score pain scores (difference, 15.2; P < .001) than those not booked, with no significant difference prior. There was a 27% chance of not improving if predicted at risk, and a 1.4% chance if predicted to improve. This gives a risk ratio of 19× (P < .001) for patients not improving if predicted at risk.
For a prediction tool to be clinically useful, it needs to provide a better understanding of the likely clinical outcome of an intervention than existed without its use when the clinical decisions are made. The tool presented here has the potential to direct patients to surgical or nonsurgical pathways on a patient-specific basis, ensuring patients who will benefit most from TKA surgery are selected.
Introduction
Tibial component design and positioning contribute more to patient satisfaction than previously realized. A surgeon needs to decide on the size and rotation, bearing in mind that ...coverage should be as high as possible, whilst malrotation and overhang should be avoided. No study investigates the impact of each of these components on clinical outcomes in a single cohort.
Materials and methods
This is a retrospective analysis of 1-year postoperative outcomes measured with the Knee Injury and Osteoarthritis Outcome (KOOS) Score, as well as a previously validated rotational CT protocol. Coverage, rotation from Insall’s axis, and overhang of an asymmetric tibial baseplate were measured, and positive and negative correlations to clinical outcomes were calculated.
Results
A total of 499 knees were analyzed. Patient average age was 68.4 years. Rotation within 7° internal and 5° external from Insall’s axis was a “safe zone”. Mean coverage was 76%. A total of 429 knees (94%) had a coverage of at least 70% and 102 knees (22%) greater than 80%. Overhang was detected in 23% of the cohort. Increased coverage was correlated to increased KOOS score and overhang correlated with a decreased KOOS score (
p
= 0.008).
Conclusions
This study demonstrates the individual role of three aspects of tibial component implantation properties in postoperative pain and short-term functional outcomes. Upsizing to the point of overhang with rotational tolerance of 7° internal and 3° external to Insall’s axis demonstrates best patient reported outcomes. Overhang decreases the clinical outcome by the same margin as loss of 16% of coverage.
Component alignment variation following total knee arthroplasty (TKA) does not fully explain the instance of long-term postoperative pain. Joint dynamics following TKA vary with component alignment ...and patient-specific musculoskeletal anatomy. Computational simulations allow joint dynamics outcomes to be studied across populations. This study aims to determine if simulated postoperative TKA joint dynamics correlate with patient-reported outcomes.
Landmarking and 3D registration of implants was performed on 96 segmented postoperative computed tomography scans of TKAs. A cadaver rig–validated platform for generating patient-specific simulation of deep knee bend kinematics was run for each patient. Resultant dynamic outcomes were correlated with a 12-month postoperative Knee Injury and Osteoarthritis Outcome Score (KOOS). A Classification and Regression Tree (CART) was used for determining nonlinear relationships.
Nonlinear relationships between the KOOS pain score and rollback and dynamic coronal alignment were found to be significant. Combining a dynamic coronal angular change from extension to full flexion between 0° and 4° varus (long leg axis) and measured rollback of no more than 6 mm without rollforward formed a “kinematic safe zone” of outcomes in which the postoperative KOOS score is 10.5 points higher (P = .013).
The study showed statistically significant correlations between kinematic factors in a simulation of postoperative TKA and postoperative KOOS scores. The presence of a dynamic safe zone in the data suggests a potential optimal target for any given individual patient's joint dynamics and the opportunity to preoperatively determine a patient-specific alignment target to achieve those joint dynamics.
Optimal rotational alignment of the femoral component is a common goal during total knee arthroplasty. The posterior condylar axis (PCA) is thought to be the most reproducible reference in surgery, ...while the transepicondylar axis (TEA) seems to better approximate the native kinematic flexion axis. This study sought to determine if rules based on patient gender or coronal alignment could allow reliable reproduction of the TEA from the PCA.
Three-dimensional models based on preoperative computed tomography were made representing a patient's arthritic knee joint. The landmarks were defined and angular relationships determined.
The population group of 726 patients contained large anatomic variation. When applying the standard reference rule of 3° external rotation from the PCA, 36.9% of patients would have a rotational target greater than ±2° from their TEA. When applying the mean external rotation of the TEA from the PCA (1.85°) from this population, this proportion dropped to 26.0% of patients. The use of statistically significant gender and coronal alignment relationships to define the femoral rotation did not reduce the proportion of patients in ±2° error.
This study shows that gender and coronal alignment relationships to the TEA to PCA angle are not clinically significant as a quarter of patients would still have a target for rotation greater than ±2° from the TEA using these relationships. Superior tools for orienting rotational cuts directly to the TEA in surgery or preoperative identification of relevant patient-specific angles might capture the proportion of patients for whom standard reference angles are not appropriate.
Successful component alignment is a major metric of success in total knee arthroplasty. Component translational placement, however, is less well reported despite being shown to affect patient ...outcomes. CT scans and planar X-rays are routinely used to report alignment but do not report measurements as precisely or accurately as modern navigation systems can deliver, or with reference to the pre-operative anatomy.
A method is presented here that utilises a CT scan obtained for pre-operative planning and a post-operative CT scan for analysis to recreate a computation model of the knee with patient-specific axes. This model is then used to determine the post-operative component position in 3D space.
Two subjects were investigated for reproducibility producing 12 sets of results. The maximum error using this technique was 0.9° ± 0.6° in rotation and 0.5 mm ± 0.3 mm in translation. Eleven subjects were investigated for reliability producing 22 sets of results. The intra-class correlation coefficient for each of the three axes of rotation and three primary resection planes was > 0.93 indicating excellent reliability.
Routine use of this analysis will allow surgeons and engineers to better understand the effect of component alignment as well as the placement on outcome.
Abstract
Introduction
Total Knee Arthroplasty (TKA) for both patients and the surgical team is a journey spanning many months, rather than purely a hospital episode of care. To improve patient ...outcomes and reduce costs in TKA, greater emphasis should be placed on the pre- and postoperative periods as, historically, innovation has focused on the intraoperative execution of the surgery. The purpose of this study was to determine if a pre- and postoperative physiotherapy program delivered via a digital application could reduce hospital length of stay (LOS) without compromising patient outcomes.
Methods
A retrospective series of 294 patients who underwent TKA from a single-surgeon in a single-centre was examined. This included 232 patients who underwent a pre- and postoperative physiotherapist-led program delivered via a digital application and 62 patients who underwent a conventional pre- and postoperative protocol. 2:1 nearest neighbour propensity score matching was performed to establish covariate balance between the cohorts. Data collected included pre- and postoperative Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS for Joint Replacement (KOOS, JR), and acute, rehabilitation, and total LOS.
Results
No significant difference in KOOS or KOOS, JR scores was observed at 12-month follow-up. A significantly reduced rehabilitation (
P
= 0.014) and total LOS (
P
= 0.015) was observed in the patients who received the digital physiotherapy program.
Conclusions
There may be significant economic benefits to a pre- and postoperative physiotherapy program delivered via a digital application. Our results suggest that a digital physiotherapist-led patient program may reduce the need for inpatient rehabilitation services without compromising patient outcomes.
Acetabular and femoral component positioning are important considerations in reducing adverse outcomes after total hip arthroplasty (THA). Previous assessments of femoral anteversion examined ...anatomic femoral anteversion (AFA) referenced to anatomic landmarks. However, this does not provide a functional understanding of the femur’s relationship to the hip. We investigate a new measurement, functional femoral anteversion (FFA), and sought to measure its variability across a large sample of patients undergoing THA.
A total of 1008 consecutive patients underwent THA surgery between September 2019 and July 2021. All patients were measured for supine and standing functional femoral rotation (FFR), AFA, and FFA.
The mean standing FFA was 13.2° ± 12.2° (−27.8° to 52.3°). The mean change in FFR from supine to standing was −2.2° ± 11.8° (−43.0° to 41.9°). Of all, 161 (16%) patients had standing FFA version greater than 25°. Four hundred sixty (46%) patients had standing FFR (internal or external) greater than 10°. One hundred twenty-three (12%) patients exhibited an increase in external rotation from supine to standing of greater than 10°. A moderate, negative linear relationship was observed between AFA and standing external femoral rotation (P <<.001, R = −0.46), indicating people may externally rotate their femur as AFA decreases with age.
Functional alignment of the femur in patients requiring THA is understudied. It is now understood that the femur, like the pelvis, can rotate substantially between functional positions. Enhancing our understanding of FFA and FFR may improve both acetabular and femoral component positioning.
Leg length discrepancy (LLD) is a common pre- and postoperative issue in total hip arthroplasty (THA) patients. The conventional technique for measuring LLD has historically been on a ...non-weightbearing anteroposterior pelvic radiograph; however, this does not capture many potential sources of LLD. The aim of this study was to determine if long-limb EOS radiology can provide a more reproducible and holistic measurement of LLD.
In all, 93 patients who underwent a THA received a standardized preoperative EOS scan, anteroposterior (AP) radiograph, and clinical LLD assessment. Overall, 13 measurements were taken along both anatomical and functional axes and measured twice by an orthopaedic fellow and surgical planning engineer to calculate intraoperator reproducibility and correlations between measurements.
Strong correlations were observed for all EOS measurements (r
> 0.9). The strongest correlation with AP radiograph (inter-teardrop line) was observed for functional-ASIS-to-floor (functional) (r
= 0.57), much weaker than the correlations between EOS measurements. ASIS-to-ankle measurements exhibited a high correlation to other linear measurements and the highest ICC (r
= 0.97). Using anterior superior iliac spine (ASIS)-to-ankle, 33% of patients had an absolute LLD of greater than 10 mm, which was statistically different from the inter-teardrop LLD measurement (p < 0.005).
We found that the conventional measurement of LLD on AP pelvic radiograph does not correlate well with long leg measurements and may not provide a true appreciation of LLD. ASIS-to-ankle demonstrated improved detection of potential LLD than other EOS and radiograph measurements. Full length, functional imaging methods may become the new gold standard to measure LLD.Cite this article:
2022;3(12):960-968.
Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the ...iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation.
This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months' follow-up. 3D models of each patient's prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model's sensitivity, specificity, and area under the curve (AUC).
Highly significant differences between the symptomatic and asymptomatic cohorts were observed for iliopsoas impingement. Logistic regression models determined that the impingement values significantly predicted the probability of groin pain. The simulation had a sensitivity of 74%, specificity of 100%, and an AUC of 0.86.
We developed a computational model that can quantify iliopsoas impingement and verified its accuracy in a case-controlled investigation. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis.Cite this article:
2023;4(1):3-12.
Background
Fluorine-18 fluorodeoxyglucose (FDG)-positron emission tomography/computed tomography (PET/CT) is widely used for staging high-grade lymphoma, with the time to evaluate such studies ...varying depending on the complexity of the case. Integrating artificial intelligence (AI) within the reporting workflow has the potential to improve quality and efficiency. The aims of the present study were to evaluate the influence of an integrated research prototype segmentation tool implemented within diagnostic PET/CT reading software on the speed and quality of reporting with variable levels of experience, and to assess the effect of the AI-assisted workflow on reader confidence and whether this tool influenced reporting behaviour.
Methods
Nine blinded reporters (three trainees, three junior consultants and three senior consultants) from three UK centres participated in a two-part reader study. A total of 15 lymphoma staging PET/CT scans were evaluated twice: first, using a standard PET/CT reporting workflow; then, after a 6-week gap, with AI assistance incorporating pre-segmentation of disease sites within the reading software. An even split of PET/CT segmentations with gold standard (GS), false-positive (FP) over-contour or false-negative (FN) under-contour were provided. The read duration was calculated using file logs, while the report quality was independently assessed by two radiologists with >15 years of experience. Confidence in AI assistance and identification of disease was assessed via online questionnaires for each case.
Results
There was a significant decrease in time between non-AI and AI-assisted reads (median 15.0 vs. 13.3 min,
p
< 0.001). Sub-analysis confirmed this was true for both junior (14.5 vs. 12.7 min,
p
= 0.03) and senior consultants (15.1 vs. 12.2 min,
p
= 0.03) but not for trainees (18.1 vs. 18.0 min,
p
= 0.2). There was no significant difference between report quality between reads. AI assistance provided a significant increase in confidence of disease identification (
p
< 0.001). This held true when splitting the data into FN, GS and FP. In 19/88 cases, participants did not identify either FP (31.8%) or FN (11.4%) segmentations. This was significantly greater for trainees (13/30, 43.3%) than for junior (3/28, 10.7%,
p
= 0.05) and senior consultants (3/30, 10.0%,
p
= 0.05).
Conclusions
The study findings indicate that an AI-assisted workflow achieves comparable performance to humans, demonstrating a marginal enhancement in reporting speed. Less experienced readers were more influenced by segmentation errors. An AI-assisted PET/CT reading workflow has the potential to increase reporting efficiency without adversely affecting quality, which could reduce costs and report turnaround times. These preliminary findings need to be confirmed in larger studies.