The behaviour of the fast particle population during 18 keV hydrogen and 26 keV deuterium neutral beam injection in deuterium plasmas is investigated. Experiments reveal large fast ion losses. The ...experimental results are confirmed using different types of modelling: simulation using the NUBEAM module, solution of the Boltzmann kinetic equation and solution of the 3D fast ion tracking algorithm. The dynamics of the energetic particle redistribution and losses during sawtooth oscillation and toroidal Alfvén eigenmodes are studied. A method to decrease fast ion losses under the current conditions (0.4 T, 0.2 MA) is shown. The influence of the plasma parameters on the energetic ion confinement rate is investigated. Modelling for the Globus-M2 conditions (1 T, 0.5 MA) is performed.
The results of a multi-diagnostic approach for geodesic acoustic mode (GAM) studies in the spherical torus Globus-M are presented. The GAM oscillations of radial electric field, plasma density and ...magnetic field were simultaneously observed. The spatial structures of crucial plasma parameters are exhibited and discussed. The intermittent character of the GAM manifests itself as a modulation at two time-scales: equilibrium time scale and the characteristic time for limit-cycle oscillations. The mutual influence of GAM oscillations and turbulence is demonstrated by bicoherence analysis.
Abstract
Doppler backscattering (DBS) was successfully previously used on the Globus-M tokamak. The diagnostic was utilised in the form of either a single-frequency or a four-frequency dual homodyne ...system. It was used primarily for the study of zonal flows, filaments and Alfvén eigenmodes. These phenomena are worth being studied both on the periphery and in the core region of the plasma in a tokamak. For this specific reason two multifrequency DBS systems were installed on the upgraded Globus-M2 tokamak. The first four-frequency system with dual homodyne detection had already been used on the Globus-M tokamak and has lower probing frequencies which provide measurements from the periphery plasma. The second and new six-frequency DBS system was installed with a non-linear transmission line that was adapted to generate probing signals at frequencies 50, 55, 60, 65, 70 and 75 GHz. In general, the range of probing frequencies corresponds to the region of critical plasma densities from 5 × 10
18
to 7 × 10
19
m
−3
at normal incidence. The pyramidal horn antennas are located inside the vacuum vessel with a special cardan-like rotator outside the camera so as to tilt antennas in the toroidal and poloidal directions. A previously developed code was applied to simulate 3D raytracing for all frequency channels. Calculations were carried out for different angles of incidence and for different electron density distributions in order to investigate the possibilities of the implementation of radial and poloidal correlation Doppler reflectometry. Examples of the DBS system application for study of plasma properties in the Globus-M2 tokamak are presented.
It is shown that the radial profile of the electron temperature in the Globus-M2 spherical tokamak is related to the radial profile of the electron density by a power law
. An analytical model of the ...density attractor, assuming the dependence of
on the specific poloidal volume
v
, previously tested on the TCV and JET tokamaks with a large aspect ratio, holds on the spherical tokamak, and the approximation of 162 experimental profiles has resulted in
. The proposed model makes it possible to calculate the spatial distribution
and
according to a known magnetic configuration.
Abstract
Active NPA measurements of the fast ion distribution using the neutral beam as an additional charge exchange target are discussed. Expressions for the calculation of the NPA signal based on ...the fast ion distribution and for the reconstruction of the fast ion distribution from the NPA signal are provided. Demonstration of the described approach is carried out on the Globus-M2 spherical tokamak, where a scanning system for the NPAs was recently installed. Main features of the active NPA application on Globus-M2 are considered. The energy and spatial distributions of fast deuterium ions at dedicated pitch angles are obtained and compared with the calculated ones. Key traits of the obtained distributions are considered and explained.
The engineering part of the GLOBSYS code is presented, and the parameters of the Globus-3 facility, which is a development of the Globus program, are analyzed. The facility is primarily designed to ...provide a long pulse, a large toroidal magnetic field and strong heating. The concepts of searching for Globus-3 parameters under physical and engineering limitations are described. Obviously that reliable confinement and a large part of noninductive current are necessary to ensure existence of a plasma for a long time. Engineering constraints are involved in the choice of parameters in a more complex way: in some cases, it is overheating of the coils, in other cases, it is the total power supply, or the limit on the flux provided by the ohmic solenoid, or the strength of the constructions. The parameters of the Globus-3 spherical tokamak were preliminarily selected for the cases of a “warm” copper EMS (Electromagnetic system) and the EMS precooled to liquid nitrogen temperature. The exceeding of the duration of the plasma current plateau Δ
t
plateau
over the characteristic settling time of the plasma profiles τ
L
/
R
was chosen as the key condition. At values of the toroidal magnetic field
B
t
0
= 3 T, the condition Δ
t
plateau
> τ
L
/
R
cannot be attained even for precooled EMS. At
B
t
0
= 2 T, only options with precooled EMS can be considered acceptable, but the facility dimensions are fairly large. For the field
B
t
0
= 1.5 T, the options with “warm” EMS correspond to the duration of the plasma current plateau ~3 s (Δ
t
plateau
/τ
L
/
R
~ 1–1.5). In the case of precooled EMS, the duration of the plateau can increase to 12–13 s (Δ
t
plateau
/τ
L
/
R
~ 5). In the latter case, as a basis for further development of the Globus-3 facility, options with the following geometric dimensions are reasonable:
R
0
~ 0.6–0.7 m,
a
~ 0.35–0.4 m,
А
≤ 1.7–1.8,
k
95
~ 1.7–1.8. The minimum allowable value of the plasma current
under the condition of effective absorption of the input power of neutral injection has been calculated. In the Globus-3 facility,
I
p
≈ 0.8 MA was chosen as the base value.
Ion temperature is one of the most important parameters of high-temperature plasma. Information on the ion temperature spatial distribution is necessary for understanding and modelling of particle ...and energy transport processes, evaluating the effectiveness of plasma heating system operation. Active spectroscopy also known as CXRS (Charge eXchange Recombination Spectroscopy) is a powerful diagnostic tool for measurements of local values of ion temperature, and is widely used in experiments with magnetic confinement of high-temperature plasma. Active spectroscopy diagnostics on the Globus-M tokamak utilizes a tangentially injected heating beam of neutrals (hydrogen or deuterium atoms). The CXRS-system setup is described. The results of ion temperature measurements for the last Globus-M experimental campaign before the machine shutdown and further upgrading to higher values of magnetic field and plasma current are presented. Ion temperature significant rise in the experiments with moderate increasing of toroidal magnetic field and plasma current is detected and discussed.
The concept of next-generation spherical tokamak is being considered: the Globus-3 project, which, in its characteristics, is compatible with the infrastructure existing at the Ioffe Institute, but ...differs from the currently operating Globus-M2 tokamak in the stronger toroidal magnetic field (1.5–3.0 T) and increased duration of plasma discharge. The parametric analysis data are presented that determined the preliminary selection of the facility parameters. Three options for the electromagnetic system were considered: with the warm copper coils, with the pre-cooled copper coils and with the coils made of high-temperature superconductors. For the first option, the concept for designing the electromagnetic system and vacuum vessel of the facility has been developed. The basic shot scenario with duration of up to 3 s at the field of 1.5 T and plasma current of 0.8 MA is presented.
The paper is devoted to the IPM-2 ion source ion-optical system preparation for the plasma heating experiments with a neutral beam in the Globus-M2 spherical tokamak. Within the framework of this ...work, a complete renovation of the ion-optical system of the ion source was carried out, including its assembly, adjustment, and testing. To assess the quality of the work performed, measurements were made of the main electrical parameters of the high-energy beam, its energy spectrum and signals from secondary emission probes. Based on the data obtained, the beam power distribution profile and its characteristic dimensions are reconstructed, and the relative concentrations of the energy components of the beam are calculated.
The results of measuring the electron temperature and density spatial distributions in plasma of the Globus-M2 tokamak using the Thomson scattering diagnostics are presented. The diagnostics provides ...measurements throughout the entire tokamak discharge, starting from time of gas breakdown. The Thomson scattering data were analyzed in order to determine the positions of the last closed flux surface, the plasma magnetic axis, and the radius of inversion during the saw-tooth oscillations. The results of measurements performed during the internal reconnection of magnetic field lines are presents, as well as the dynamics of spatial distributions of electron temperature, density and pressure during the plasma transition to the H-mode. The results of measuring the electron temperature distribution in the scrape-off layer using the Thomson scattering diagnostics are also presented for distances up to 4 cm outside the last closed flux surface.