The BNT162b2 messenger RNA (mRNA) vaccine against severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) has been shown to be safe and effective in immunocompetent patients. The safety and ...efficacy of this vaccine in liver transplantation (LT) recipients is still under evaluation. The objective of this study was to assess the safety and efficacy of the BNT162b2 vaccine among transplant recipients. The immune responses of 76 LT recipients receiving 2 doses of the vaccine were compared with those of 174 age‐matched immunocompetent controls. Postvaccination immunoglobulin G (IgG) antibodies against the receptor‐binding domain (RBD) of SARS‐CoV‐2 and neutralizing antibodies (NA) to the BNT162b2 mRNA vaccine were determined at least 14 days after the second dose of the vaccine. IgG antibody titers ≥1.1 were defined as positive antibodies. Adverse effects were monitored during the study period. Following administration of the second dose, transplant recipients showed reduced immune responses compared with controls (72% versus 94.2%; P < 0.001). At a median time of 38 days after the second vaccination, the geometric mean of RBD IgG and NA titers were 2.1 (95% confidence interval CI, 1.6‐2.6) and 150 (95% CI, 96‐234) among transplant recipients and 4.6 (95% CI, 4.1‐5.1) and 429 (95% CI, 350‐528) in the control group, respectively (P < 0.001). Antibody responses were lower in transplant recipients who were receiving combined immunosuppression therapy and in those with impaired renal function. Among the LT recipients with negative antibody responses, 1 became infected with SARS‐CoV‐2, but no recipients with positive antibody responses became infected. Overall, most (n = 39 51%) adverse effects self‐reported by transplant recipients were mild and occurred more often in women than in men. Compared with patients who were immunocompetent, LT recipients had lower immune responses. The durability of immune responses to the BNT162b2 vaccine among LT recipients requires further investigation.
We identified Usutu virus (USUV) RNA in 6 pools of mosquitoes trapped in northern Israel during 2014-2015. These Israeli strains were most similar to strains identified in Senegal and Germany, which ...further elucidates common ancestry and evolutionary dynamics of USUV. Our findings suggest that human infection with USUV might occur in Israel.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, ODKLJ, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The COVID-19 pandemic and the fast global spread of the disease resulted in unprecedented decline in world trade and travel. A critical priority is, therefore, to quickly develop serological ...diagnostic capacity and identify individuals with past exposure to SARS-CoV-2. In this study serum samples obtained from 309 persons infected by SARS-CoV-2 and 324 of healthy, uninfected individuals as well as serum from 7 COVID-19 patients with 4-7 samples each ranging between 1-92 days post first positive PCR were tested by an "in house" ELISA which detects IgM, IgA and IgG antibodies against the receptor binding domain (RBD) of SARS-CoV-2. Sensitivity of 47%, 80% and 88% and specificity of 100%, 98% and 98% in detection of IgM, IgA and IgG antibodies, respectively, were observed. IgG antibody levels against the RBD were demonstrated to be up regulated between 1-7 days after COVID-19 detection, earlier than both IgM and IgA antibodies. Study of the antibody kinetics of seven COVID 19 patients revealed that while IgG levels are high and maintained for at least 3 months, IgM and IgA levels decline after a 35-50 days following infection. Altogether, these results highlight the usefulness of the RBD based ELISA, which is both easy and cheap to prepare, to identify COVID-19 patients even at the acute phase. Most importantly our results demonstrate that measuring IgG levels alone is both sufficient and necessary to diagnose past exposure to SARS-CoV-2.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The Bio-Rad Geenius HIV 1/2 assay was evaluated as an alternative to the INNO-LIA HIV 1/2 assay for the confirmation of HIV infection in 198 serum samples reactive to 4th-generation HIV enzyme ...immunoassays (EIAs). The Geenius assay correctly identified 85% of the samples, compared to 75% identified by the INNO-LIA assay, reduced the number of indeterminate results, and shortened the overall turnaround time.
Genetic diversity is the fuel of evolution and facilitates adaptation to novel environments. However, our understanding of what drives differences in the genetic diversity during the early stages of ...viral infection is somewhat limited. Here, we use ultra-deep sequencing to interrogate 43 clinical samples taken from early infections of the human-infecting viruses HIV, RSV and CMV. Hundreds to thousands of virus templates were sequenced per sample, allowing us to reveal dramatic differences in within-host genetic diversity among virus populations. We found that increased diversity was mostly driven by presence of multiple divergent genotypes in HIV and CMV samples, which we suggest reflect multiple transmitted/founder viruses. Conversely, we detected an abundance of low frequency hyper-edited genomes in RSV samples, presumably reflecting defective virus genomes (DVGs). We suggest that RSV is characterized by higher levels of cellular co-infection, which allow for complementation and hence elevated levels of DVGs.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Respiratory viral infections constitute the majority of samples tested in the clinical virology laboratory during the winter season, and are mainly diagnosed using molecular assays, namely real-time ...PCR (qPCR). Therefore, a high-quality extraction process is critical for successful, reliable and sensitive qPCR results. Here we aimed to evaluate the performance of the newly launched eMAG compared to the fully automated MagNA PURE 96 (Roche, Germany) and to the semi-automated easyMAG (bioMerieux, France) extraction platforms. For this analysis, we assessed and compared the analytic and clinical performance of the three platforms, using 262 archived respiratory samples positive or negative to common viruses regularly examined in our laboratory (influenza A, B, H1N1pdm, Respiratory Syncytial Virus (RSV), human Metapneumovirus (hMPV), parainfluenza-3, adenovirus and negative samples). In addition, quantitated virus controls were used to determine the limit of detection of each extraction method. In all categories tested, eMAG results were comparable to those of the easyMAG and MagNa PURE 96, highly sensitive for all viruses and over 98% clinical specificity and sensitivity for all viruses tested. Together with its high level of automation, the bioMerieux eMAG is a high-quality extraction platform enabling effective molecular analysis and is mostly suitable for medium-sized laboratories.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
This study presents an analysis of the epidemiological trends of parvovirus B19 (B19V) in Israel from 2010 to 2023, with particular emphasis on the outbreak in 2023. The analysis utilized molecular ...diagnostic data from individual patients obtained at the Central Virology Laboratory. Between 2010 and 2022, 8.5% of PCR-tested samples were positive for B19V, whereas in 2023, this percentage surged to 31% of PCR-tested samples. Throughout the study period, annual cycles consistently peaked in early spring/summer, with the most recent prominent outbreak occurring in 2016. Predominantly, diagnoses were made in children and women aged 20-39. Despite the notable surge in 2023, over 80% of positive cases continued to be observed in children and young women, with a decrease in cases during winter months. Furthermore, genotype 1a of the virus remained the predominant strain circulating during the outbreak. In light of these circumstances, consideration should be given to implementing screening measures, particularly among high-risk groups such as pregnant women.
Conducting numerous, rapid, and reliable PCR tests for SARS-CoV-2 is essential for our ability to monitor and control the current COVID-19 pandemic. Here, we tested the sensitivity and efficiency of ...SARS-CoV-2 detection in clinical samples collected directly into a mix of lysis buffer and RNA preservative, thus inactivating the virus immediately after sampling. We tested 79 COVID-19 patients and 20 healthy controls. We collected two samples (nasopharyngeal swabs) from each participant: one swab was inserted into a test tube with Viral Transport Medium (VTM), following the standard guideline used as the recommended method for sample collection; the other swab was inserted into a lysis buffer supplemented with nucleic acid stabilization mix (coined NSLB). We found that RT-qPCR tests of patients were significantly more sensitive with NSLB sampling, reaching detection threshold 2.1±0.6 (Mean±SE) PCR cycles earlier then VTM samples from the same patient. We show that this improvement is most likely since NSLB samples are not diluted in lysis buffer before RNA extraction. Re-extracting RNA from NSLB samples after 72 hours at room temperature did not affect the sensitivity of detection, demonstrating that NSLB allows for long periods of sample preservation without special cooling equipment. We also show that swirling the swab in NSLB and discarding it did not reduce sensitivity compared to retaining the swab in the tube, thus allowing improved automation of COVID-19 tests. Overall, we show that using NSLB instead of VTM can improve the sensitivity, safety, and rapidity of COVID-19 tests at a time most needed.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Combined antiretroviral treatment (cART) traditionally consists of three antiretroviral medications, while two-drug regimens (2DR), historically used infrequently, recently been suggested to be ...non-inferior to three-drug regimens, is emerging as a potential treatment option and is currently a recommended option for treatment initiation in many guidelines.
Characterize the indications and clinical efficacy of 2DR use at a real-life setting in a nation-wide survey.
A cross-sectional survey of Israeli patients treated by 2DR until July 2019, included demographic, immunologic, virologic, genotypic and biochemical/metabolic parameters at diagnosis, ART initiation, 2DR initiation and following 24, 48, 96 and 144 weeks of 2DR treatment.
176 patients were included in the study. In contrast to historical data implicating ART resistance and adverse effects as the major reasons leading to 2DR switching, treatment simplification was the main reason leading to 2DR treatment in 2019. 2DR that included INSTI and PI were more commonly used in cases of drug resistance, while a combination of INSTI and NNRTI was used in all other 2DR indications. A switch to 2DR induced a mean CD4 T cell increase from 599 cells/μl at treatment initiation to 680 cells/μl at 96 weeks of treatment p<0.001 and viral suppression improvement from 73.9% at initiation to 87.0% at 48 weeks of treatment (p = 0.004). PI and INSTI 2DR was inferior in suppressing viral levels compared to other 2DRs but used for subset of more complex patients.
2DR in a large-scale real-life nation-wide survey proved to be safe and effective. Most 2DRs, other than PI and INSTI, were similarly effective in suppressing HIV viremia and in elevating CD4 T cell counts.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Accurate and timely diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is clinically essential, and is required also to monitor confirmed cases aiming to prevent further ...spread. Positive real-time PCR results at late time points following initial diagnosis may be clinically misleading as this methodology cannot account for the infection capabilities and the existence of whole genome sequences. In this study, 47 serial respiratory samples were tested by Allplex-nCoV test (Seegene), a triplex of three assays targeting the SARS-CoV-2 RdRP, E and N genes and subsequently assessed by next generation sequencing (NGS). COVID19 patients were tested at an early stage of the disease, when all these viral gene targets were positive, and at an advanced stage, when only the N gene target was positive in the Allplex-nCoV test. The corresponding NGS results showed the presence of complete viral genome copies at both early and advanced stages of the disease, although the total number of mapped sequences was lower in samples from advanced disease stages. We conclude that reduced viral transmission at this late disease stage may result from the low quantities of complete viral sequences and not solely from transcription favoring the N gene.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK