We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 μT magnetic field. Multiple circularly polarized laser beams were used to probe the free ...spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scalar resolution of less than 80 fT was reached with integration times of 1.6 to 6 s. We were able to measure the magnetic field direction with a resolution better than 10 μrad for integration times from 10 s up to 2000 s.
We report a new limit on a possible short range spin-dependent interaction from the precise measurement of the ratio of Larmor precession frequencies of stored ultracold neutrons and Hg199 atoms ...confined in the same volume. The measurement was performed in a ∼1μT vertical magnetic holding field with the apparatus searching for a permanent electric dipole moment of the neutron at the Paul Scherrer Institute. A possible coupling between freely precessing polarized neutron spins and unpolarized nucleons of the wall material can be investigated by searching for a tiny change of the precession frequencies of neutron and mercury spins. Such a frequency change can be interpreted as a consequence of a short range spin-dependent interaction that could possibly be mediated by axions or axion-like particles. The interaction strength is proportional to the CP violating product of scalar and pseudoscalar coupling constants gSgP. Our result confirms limits from complementary experiments with spin-polarized nuclei in a model-independent way. Limits from other neutron experiments are improved by up to two orders of magnitude in the interaction range of 10−6<λ<10−4m.
In case a mirror world with a copy of our ordinary particle spectrum would exist, the neutron n and its degenerate partner, the mirror neutron n', could potentially mix and undergo nn' oscillations. ...The interaction of an ordinary magnetic field with the ordinary neutron would lift the degeneracy between the mirror partners, diminish the n' amplitude in the n wave function and, thus, suppress its observability. We report an experimental comparison of ultracold neutron storage in a trap with and without superimposed magnetic field. No influence of the magnetic field is found and, assuming negligible mirror magnetic fields, a limit on the oscillation time taunn' > 103 s (95% C.L.) is derived.
High precision mapping of weak magnetic fields is of interest for several branches of pure and applied research. This paper presents a resume of the progress made at Fribourg in adapting laboratory ...style laser-pumped optical Cs magnetometers to multisensor field mapping problems. Progress has been made in sensor head design and manufacture, laser beam splitting and control, and signal treatment electronics. A summary of the technology and its applications are presented.
A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and 199Hg atoms, is reported. No daily variation of this ratio could be found, from ...which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field b perpendicular < 2 x 10(-20) eV (95% C.L.). This is the first limit for the free neutron. This result is also interpreted as a direct limit on the gravitational dipole moment of the neutron |gn| < 0.3 eV/c2 m from a spin-dependent interaction with the Sun. Analyzing the gravitational interaction with the Earth, based on previous data, yields a more stringent limit |gn| < 3 x 10(-4) eV/c2 m.
The PSI ultra-cold neutron source Anghel, A.; Atchison, F.; Blau, B. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2009, Letnik:
611, Številka:
2
Journal Article
Recenzirano
A new type of ultra-cold neutron (UCN) source based on the spallation process is under construction at PSI. The essential elements are a pulsed proton beam with highest intensity (
I
p
≥
2
mA
) and a ...low duty cycle (1%), a lead spallation target, a large
D
2
O
moderator and a solid deuterium (
sD
2
) converter system. Spallation neutrons are thermalized in the
D
2
O
, further cooled and partially downscattered into the ultra-cold neutron range in the
sD
2
. The expected UCN density is higher than
1000
UCN
/
cm
3
in typical experiments, an increase of almost two orders of magnitude over the best source currently available (at ILL). The new UCN source is expected to come into operation in 2009.
A method to localize gamma-ray bursts using POLAR Suarez-Garcia, E.; Haas, D.; Hajdas, W. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2010, Letnik:
624, Številka:
3
Journal Article
Recenzirano
Odprti dostop
The hard X-ray polarimeter POLAR aims to measure the linear polarization of the 50–500
keV photons arriving from the prompt emission of
γ
-ray
bursts (GRBs). The position in the sky of the detected ...GRBs is needed to determine their level of polarization. We present here a method by which, despite of the polarimeter incapability of taking images, GRBs can be roughly localized using POLAR alone. For this purpose scalers are attached to the output of the 25 multi-anode photomultipliers (MAPMs) that collect the light from the POLAR scintillator target. Each scaler measures how many GRB photons produce at least one energy deposition above 50
keV in the corresponding MAPM. Simulations show that the relative outputs of the 25 scalers depend on the GRB position. A database of very strong GRBs simulated at 10
201 positions has been produced. When a GRB is detected, its location is calculated searching the minimum of the
χ
2
obtained in the comparison between the measured scaler pattern and the database. This GRB localization technique brings enough accuracy so that the error transmitted to the 100% modulation factor is kept below 10% for GRBs with fluence
F
tot
≥
10
−
5
erg
cm
−
2
. The POLAR localization capability will be useful for those cases where no other instruments are simultaneously observing the same field of view.
We report a measurement of the reflection of ultracold neutrons from flat, large-area plates of different Fermi potential materials with low surface roughness. The results were used to test two ...diffuse reflection models, the well-known Lambert model and the micro-roughness model which is based on wave scattering. The Lambert model fails to reproduce the diffuse reflection data. The surface roughness
b
and correlation length
w
, obtained by fitting the micro-roughness model to the data are in the range 1
b
3 nm and 10
w
120 nm, in qualitative agreement with independent measurements using atomic force microscopy.