Eye tracking studies have analyzed the relationship between visual attention to point of purchase marketing elements (price, signage, etc.) and purchase intention. Our study is the first to ...investigate the relationship between the gaze sequence in which consumers view a display (including gaze aversion away from products) and the influence of consumer (top down) characteristics on product choice. We conducted an in-lab 3 (display size: large, moderate, small) X 2 (price: sale, non-sale) within-subject experiment with 92 persons. After viewing the displays, subjects completed an online survey to provide demographic data, self-reported and actual product knowledge, and past purchase information. We employed a random forest machine learning approach via R software to analyze all possible three-unit subsequences of gaze fixations. Models comparing multiclass F1-macro score and F1-micro score of product choice were analyzed. Gaze sequence models that included gaze aversion more accurately predicted product choice in a lab setting for more complex displays. Inclusion of consumer characteristics generally improved model predictive F1-macro and F1-micro scores for less complex displays with fewer plant sizes Consumer attributes that helped improve model prediction performance were product expertise, ethnicity, and previous plant purchases.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
This paper discusses the results of an experimental programme designed to investigate the deviatoric behaviour of peats. The results are obtained from triaxial experiments carried out on ...reconstituted peat samples. The interpretation of the experimental results follows a hierarchical approach in an attempt to derive the ingredients that an elastic–plastic model for peats should contain, including the yield locus, the hardening mechanism and the flow rule. The results obtained from stress tests along different loading directions show that purely volumetric hardening is not adequate to describe the deviatoric response of peat and that a deviatoric strain-dependent component should be included. The plastic deformation mechanism also depends on the previous stress history experienced by the sample. Stress and strain path dependence of the interaction mechanisms between the peat matrix and the fibres is discussed as a possible physical reason for the observed behaviour. This work offers a relevant set of data and information to guide the rational development and the calibration of constitutive laws able to model the deviatoric behaviour of peats.
The use and interest in Monte Carlo (MC) techniques in the field of medical physics have been rapidly increasing in the past years. This is the case especially in particle therapy, where accurate ...simulations of different physics processes in complex patient geometries are crucial for a successful patient treatment and for many related research and development activities. Thanks to the detailed implementation of physics processes in any type of material, to the capability of tracking particles in 3D, and to the possibility of including the most important radiobiological effects, MC simulations have become an essential calculation tool not only for dose calculations but also for many other purposes, like the design and commissioning of novel clinical facilities, shielding and radiation protection, the commissioning of treatment planning systems, and prediction and interpretation of data for range monitoring strategies. MC simulations are starting to be more frequently used in clinical practice, especially in the form of specialized codes oriented to dose calculations that can be performed in short time. The use of general purpose MC codes is instead more devoted to research. Despite the increased use of MC simulations for patient treatments, the existing literature suggests that there are still a number of challenges to be faced in order to increase the accuracy of MC calculations for patient treatments. The goal of this review is to discuss some of these remaining challenges. Undoubtedly, it is a work for which a multidisciplinary approach is required. Here, we try to identify some of the aspects where the community involved in applied nuclear physics, radiation biophysics, and computing development can contribute to find solutions. We have selected four specific challenges: i) the development of models in MC to describe nuclear physics interactions, ii) modeling of radiobiological processes in MC simulations, iii) developments of MC-based treatment planning tools, and iv) developments of fast MC codes. For each of them, we describe the underlying problems, present selected examples of proposed solutions, and try to give recommendations for future research.
The calculation algorithm of a modern treatment planning system for ion-beam radiotherapy should ideally be able to deal with different ion species (e.g. protons and carbon ions), to provide relative ...biological effectiveness (RBE) evaluations and to describe different beam lines. In this work we propose a new approach for ion irradiation outcomes computations, the beamlet superposition (BS) model, which satisfies these requirements. This model applies and extends the concepts of previous fluence-weighted pencil-beam algorithms to quantities of radiobiological interest other than dose, i.e. RBE- and LET-related quantities. It describes an ion beam through a beam-line specific, weighted superposition of universal beamlets. The universal physical and radiobiological irradiation effect of the beamlets on a representative set of water-like tissues is evaluated once, coupling the per-track information derived from FLUKA Monte Carlo simulations with the radiobiological effectiveness provided by the microdosimetric kinetic model and the local effect model. Thanks to an extension of the superposition concept, the beamlet irradiation action superposition is applicable for the evaluation of dose, RBE and LET distributions. The weight function for the beamlets superposition is derived from the beam phase space density at the patient entrance. A general beam model commissioning procedure is proposed, which has successfully been tested on the CNAO beam line. The BS model provides the evaluation of different irradiation quantities for different ions, the adaptability permitted by weight functions and the evaluation speed of analitical approaches. Benchmarking plans in simple geometries and clinical plans are shown to demonstrate the model capabilities.
Radiation therapy is currently the most utilized technique for the treatment of tumors by means of ionizing radiation, such as electrons, protons and x/gamma rays, depending on the type, size and ...depth of the cancer mass. Radiation therapy has in general fulfilled the main requirement of targeting thus damaging the malignant cells and sparing the healthy tissues as best as possible. In this scenario, electron linear accelerators have been operated as viable tools for the delivery of both high-energetic electrons and x-ray beams, which are obtained via the bremsstrahlung process of the electrons hitting on a high-Z material. Recently, it has been experimentally demonstrated that ultrahigh dose-rate bursts of electrons and x-ray beams increase the differential response between healthy and tumor tissues. This beneficial response is referred to as the FLASH effect. For this purpose, we have developed the first dedicated compactS-band linear accelerator for FLASH radiotherapy. This linac is optimized for a nominal energy of 7 MeV and a pulsed electron beam current of 100 mA and above. The accelerator is mounted on a remote-controlled system for preclinical research studies in the FLASH regime. We will show the rf and beam dynamics design of theS-band linac as well as the commissioning and high-power rf tests. Furthermore, the results of the dosimetric measurements will be illustrated.
The high dose conformity and healthy tissue sparing achievable in Particle Therapy when using C ions calls for safety factors in treatment planning, to prevent the tumor under-dosage related to the ...possible occurrence of inter-fractional morphological changes during a treatment. This limitation could be overcome by a range monitor, still missing in clinical routine, capable of providing on-line feedback. The Dose Profiler (DP) is a detector developed within the INnovative Solution for In-beam Dosimetry in hadronthErapy (INSIDE) collaboration for the monitoring of carbon ion treatments at the CNAO facility (Centro Nazionale di Adroterapia Oncologica) exploiting the detection of charged secondary fragments that escape from the patient. The DP capability to detect inter-fractional changes is demonstrated by comparing the obtained fragment emission maps in different fractions of the treatments enrolled in the first ever clinical trial of such a monitoring system, performed at CNAO. The case of a CNAO patient that underwent a significant morphological change is presented in detail, focusing on the implications that can be drawn for the achievable inter-fractional monitoring DP sensitivity in real clinical conditions. The results have been cross-checked against a simulation study.
Positron emission tomography (PET) is one of the most mature techniques for monitoring in ion beam therapy. PET allows to reconstruct the β+ activity generated in the patient by the nuclear ...interaction of the ions. Taking advantage of the spatial correlation between positron emitters created along the ions path and the dose distribution, it is possible to perform a quality control of the treatment. Usually, to reconstruct the activity generated within the irradiated volume, standard 3D PET reconstruction techniques are implemented. In this work, we explore a new reconstruction method (Straight Forward Reconstruction) particularly useful for reconstructing activity distribution generated by mono-energetic pencil beams. The method was validated by measuring the produced activity distribution with the DoPET system. Irradiations performed with mono-energetic pencil beams on phantoms mimicking human tissues were used for this study. Both reconstruction methods reach an accuracy in the reconstruction of the activity distribution width of the order of 1.5 mm for 2⋅108 primaries.
•PET is one of the most mature techniques for monitoring in ion beam therapy.•A new reconstruction method (Straight Forward Reconstruction) for PET is presented.•Activity distribution and accuracy by pencil beams irradiation are presented.
The genus
includes tick-borne bacterial pathogens affecting humans, domestic and wild mammals.
has been identified in different animal species and geographical locations, suggesting that this is a ...widely distributed and generalist
. In the present study, we evaluated
infection in 148 Equidae presented to the Medical Clinic Department of a Veterinary Hospital from a midwestern region of Brazil. Blood samples and ticks collected from the animals were tested by Polymerase Chain Reaction (PCR) for the presence of
spp. A multigenic approach including Anaplasmataceae-specific (i.e., 16S rRNA,
,
) and
-specific (i.e.,
and
) genes was used for accurate bacteria identification. Sera samples were also collected and evaluated for the detection of anti-
antibodies by indirect fluorescent antibody test (IFA). Possible associations between molecular and serological diagnostics and clinical and hematological manifestations were tested using chi-squared or Fisher's exact tests. Sequence analysis of the
fragment revealed that three horses (2.03%) were exposed to
. Sixty-one (41.2%) Equidae (58 equines and three mules), were seropositive for
spp., with antibody titers ranging between 40 and 2560. Seropositivity to ehrlichial antigens was statistically associated with tick infestation, rural origin, hypoalbuminemia and hyperproteinemia (
≤ 0.05). The present study reports the first evidence of natural infection by
in horses from Brazil.
•The Dose Profiler is a charged fragment tracker designed for range monitoring in particle therapy.•The detector design, carefully optimized to operate in clinical environment, is described.•The ...characterization measurements have been performed using different experimental setup.•The obtained performances are suitable for range monitoring application.
Particle therapy (PT) can exploit heavy ions (such as He, C or O) to enhance the treatment efficacy, profiting from the increased Relative Biological Effectiveness and Oxygen Enhancement Ratio of these projectiles with respect to proton beams. To maximise the gain in tumor control probability a precise online monitoring of the dose release is needed, avoiding unnecessary large safety margins surroundings the tumor volume accounting for possible patient mispositioning or morphological changes with respect to the initial CT scan. The Dose Profiler (DP) detector, presented in this manuscript, is a scintillating fibres tracker of charged secondary particles (mainly protons) that will be operating during the treatment, allowing for an online range monitoring. Such monitoring technique is particularly promising in the context of heavy ions PT, in which the precision achievable by other techniques based on secondary photons detection is limited by the environmental background during the beam delivery. Developed and built at the SBAI department of “La Sapienza”, within the INSIDE collaboration and as part of a Centro Fermi flagship project, the DP is a tracker detector specifically designed and planned for clinical applications inside a PT treatment room. The DP operation in clinical like conditions has been tested with the proton and carbon ions beams of Trento proton-therapy center and of the CNAO facility. In this contribution the detector performances are presented, in the context of the carbon ions monitoring clinical trial that is about to start at the CNAO centre.