This study investigates 2 polyethers (PE), 2 polyvinylsiloxanethers (VXSE), and 10 polyvinylsiloxanes (PVS), seven of which had a corresponding light-body consistency and seven of which had a ...corresponding heavy-body consistency. Each light-body elastomer underwent a flowability test using the shark fin method 20, 50, and 80 s after mixing. The tear strength test DIN 53504 was used after setting the time (T0). Next, 24 h later (T1), hydrophilicity testing was used with static contact angles in water drops during polymerization (20, 50, and 80 s, as well as after 10 min). The heavy-body elastomers underwent shark fin testing with a corresponding light-body material at 50 and 80 s after mixing. The results of light-body testing were combined in a score to describe their performance. The highest differences were detected within flowability in shark fin heights between PE and a PVS (means of 15.89 and 6.85 mm) within the maximum tear strengths at T0 between a PVS and PE (3.72 and 0.75 MPa), as well as within hydrophilicity during setting between VXSE and a PVS (15.09° and 75.5°). The results indicate that VSXE and novel PVS materials can significantly compensate shortcomings in PE towards tear strength and hydrophilicity, but not flowability.
This study determinates the persistence of retention force in Akers-clasps for removable partial dentures made from Co-Cr alloy. Therefore, standardized computer-aided designed (CAD) clasp #1 ...specimens were made by direct metal laser melting (DMLM, n = 10) and by lost-wax dental casting (DC) of computer-aided manufactured (CAM) replicas (n = 10, DC) from two comparable Co-Cr alloys. The retention force was tested after manufacturing for 9000 cycles of setting and removal from a molar tooth crown analog made from zirconia; simulating in-vitro a duration of six years in service. The first and last 360 cycles (T0 and T1, 3 months each) of all specimens were selected for comparison of retention forces between the materials. A constant decrease of 6% from the initial retention force (T0 = 4.86 N, SD = 0.077; T1 = 4.57 N, SD = 0.037) was detected at the DC specimens, and an increase of 4% in DMLM specimens (T0 = 5.69 N, SD = 0.078; T1 = 5.92 N, SD = 0.077); all differences were statistically significant (
< 0.0001). Even if these deviations are not of clinical relevance, further studies and applications should investigate the fatigue behavior of laser melted Co-Cr-alloys for dental application.
Background
During cardiogenic shock blood circulation is minimal in the human body and does not suffice to survive. The extracorporeal life support system (ECLS) acts as a miniature ...heart-lung-machine that can be temporarily implanted over major vessels e.g. at the groin of the patient to bridge cardiogenic shock. To perform this procedure in an emergency, a proper training model is desirable. Therefore, a 3-dimensional-printable (3D) material must be found that mimics large vessel needle penetration properties. A suitable test bench for material comparison is desirable.
Methods
A test setup was built, which simulated the clinically relevant wall tension in specimens. The principle was derived from an existing standardized needle penetration test. After design, the setup was fabricated by means of 3D printing and mounted onto an universal testing machine. For testing the setup, a 3D printable polymer with low Shore A hardness and porcine aorta were used. The evaluation was made by comparing the curves of the penetration force to the standardized test considering the expected differences.
Results
3D printing proved to be suitable for manufacturing the test setup, which finally was able to mimic wall tension as if under blood pressure and penetration angle. The force displacement diagrams showed the expected curves and allowed a conclusion to the mechanical properties of the materials. Although the materials forces deviated between the porcine aorta and the Agilus30 polymer, the graphs showed similar but still characteristic curves.
Conclusions
The test bench provided the expected results and was able to show the differences between the two materials. To improve the setup, limitations has been discussed and changes can be implemented without complications.
It has long been proposed that phase-separated compartments can provide a basis for the formation of cellular precursors in prebiotic environments. However, we know very little about the properties ...of coacervates formed from simple peptides, their compatibility with ribozymes or their functional significance. Here we assess the conditions under which functional ribozymes form coacervates with simple peptides. We find coacervation to be most robust when transitioning from long homopeptides to shorter, more pre-biologically plausible heteropeptides. We mechanistically show that these RNA-peptide coacervates display peptide-dependent material properties and cofactor concentrations. We find that the interspacing of cationic and neutral amino acids increases RNA mobility, and we use isothermal calorimetry to reveal sequence-dependent Mg
partitioning, two critical factors that together enable ribozyme activity. Our results establish how peptides of limited length, homogeneity and charge density facilitate the compartmentalization of active ribozymes into non-gelating, magnesium-rich coacervates, a scenario that could be applicable to cellular precursors with peptide-dependent functional phenotypes.
Phase separation of mixtures of oppositely charged polymers provides a simple and direct route to compartmentalisation via complex coacervation, which may have been important for driving primitive ...reactions as part of the RNA world hypothesis. However, to date, RNA catalysis has not been reconciled with coacervation. Here we demonstrate that RNA catalysis is viable within coacervate microdroplets and further show that these membrane-free droplets can selectively retain longer length RNAs while permitting transfer of lower molecular weight oligonucleotides.
Amid escalating geopolitical tensions, we offers insights into the far-reaching consequences of wars. Based on a new dataset on major conflicts since 1870, the findings show that wars cause a ...substantial decline in GDP and spike in inflation within war zones. Interestingly, countries geographically close to war zones experience significant economic disruptions, even when neutral to the conflict, whereas countries far from the conflict may see minimal to slightly positive spillovers. The study demonstrates how wars represent a massive negative supply shock, with geographical proximity and trade integration explaining the varying effects on different countries.
There is considerable evidence that oxygen free radicals are involved in reperfusion injury of ischemic myocardium. Epidemiologic studies showed an inverse correlation between plasma levels of ...α-tocopherol (vitamin E) and ascorbic acid (vitamin C) and mortality from ischemic heart disease. The present study examines the influence of both vitamins on the toxic effects of singlet oxygen on isolated rat cardiomyocytes. Freshly isolated cardiomyocytes from adult rats were exposed to singlet oxygen which was generated by photoactivation of the photosensitive dye rose bengal (10
−7 M). This procedure induced irreversible hypercontracture in about 95% of rod-shaped cardiomyocytes within 15 min after onset of photoactivation of rose bengal. Pretreatment with vitamin C (10
−5 to 10
−2 M) or E (10
−6 to 10
−3 M) reduced the number of hypercontracted cells after exposure to singlet oxygen in a concentration-dependent manner. Simultaneous application of both vitamins (vitamin E 10
−6 M plus vitamin C 10
−5 M or vitamin E 10
−5 M plus vitamin C 10
−4 M) revealed a marked overadditive protective effect against oxidative damage as compared with the single application of each vitamin. Our data show that α-tocopherol and ascorbic acid exert direct protective actions on isolated cardiomyocytes against oxidative damage and provide an overadditive effect if administered simultaneously.