Placenta accreta spectrum (PAS) has become a significant life-threatening issue due to its increased incidence and associated morbidity and mortality. Pregnancy is often associated with states of ...anaemia, and severe maternal haemorrhage represents a major risk factor for red blood cell (RBC) transfusion. The present study retrospectively analyzed the prevalence of anaemia, transfusion requirements and outcome in women with PAS. Using data from the German Statistical Office pregnant patients with deliveries hospitalized between January 2012 and December 2021 were included. Primary outcome was the prevalence of anemia and administration of RBCs. Secondary outcome were complications in women with PAS who received RBC transfusion. In total 6,493,606 pregnant women were analyzed, of which 38,060 (0.59%) were diagnosed with PAS. The rate of anaemia during pregnancy (60.36 vs. 23.25%; p < 0.0001), postpartum haemorrhage (47.08 vs. 4.41%; p < 0.0001) and RBC transfusion rate (14.68% vs. 0.72%; p < 0.0001) were higher in women with PAS compared to women without PAS. Women with PAS who had bleeding and transfusion experienced significantly more peripartum complications than those who did not. A multiple logistic regression revealed that the probability for RBC transfusion in all pregnant women was positively associated with anaemia (OR 21.96 (95% CI 21.36-22.58)). In women with PAS, RBC transfusion was positively associated with the presence of renal failure (OR 11.27 (95% CI 9.35-13.57)) and congestive heart failure (OR 6.02 (95% CI (5.2-7.07)). Early anaemia management prior to delivery as well as blood conservation strategies are crucial in women diagnosed with PAS.
Estimating intraoperative blood loss is one of the daily challenges for clinicians. Despite the knowledge of the inaccuracy of visual estimation by anaesthetists and surgeons, this is still the ...mainstay to estimate surgical blood loss. This review aims at highlighting the strengths and weaknesses of currently used measurement methods. A systematic review of studies on estimation of blood loss was carried out. Studies were included investigating the accuracy of techniques for quantifying blood loss in vivo and in vitro. We excluded nonhuman trials and studies using only monitoring parameters to estimate blood loss. A meta-analysis was performed to evaluate systematic measurement errors of the different methods. Only studies that were compared with a validated reference e.g. Haemoglobin extraction assay were included. 90 studies met the inclusion criteria for systematic review and were analyzed. Six studies were included in the meta-analysis, as only these were conducted with a validated reference. The mixed effect meta-analysis showed the highest correlation to the reference for colorimetric methods (0.93 95% CI 0.91–0.96), followed by gravimetric (0.77 95% CI 0.61–0.93) and finally visual methods (0.61 95% CI 0.40–0.82). The bias for estimated blood loss (ml) was lowest for colorimetric methods (57.59 95% CI 23.88–91.3) compared to the reference, followed by gravimetric (326.36 95% CI 201.65–450.86) and visual methods (456.51 95% CI 395.19–517.83). Of the many studies included, only a few were compared with a validated reference. The majority of the studies chose known imprecise procedures as the method of comparison. Colorimetric methods offer the highest degree of accuracy in blood loss estimation. Systems that use colorimetric techniques have a significant advantage in the real-time assessment of blood loss.
Characterization of neonates born to mothers with SARS-CoV-2 infection has been partially carried out. There has been no systematic review providing a holistic neonatal presentation including ...possible vertical transmission. A systematic literature search was performed using PubMed, Google Scholar and Web of Science up to June, 6 2020. Studies on neonates born to mothers with SARS-CoV-2 infection were included. A binary random effect model was used for prevalence and 95% confidence interval. 32 studies involving 261 neonates were included in meta-analysis. Most neonates born to infected mothers did not show any clinical abnormalities (80.4%). Clinical features were dyspnea in 11 (42.3%) and fever in 9 newborns (19.1%). Of 261 neonates, 120 neonates were tested for infection, of whom 12 (10.0%) tested positive. Swabs from placenta, cord blood and vaginal secretion were negative. Neonates are mostly non affected by the mother's SARS-CoV-2 infection. The risk of vertical transmission is low.
The intraoperative blood loss is estimated daily in the operating room and is mainly done by visual techniques. Due to local standards, the surgical sponge colours can vary (e.g. white in US, green ...in Germany). The influence of sponge colour on accuracy of estimation has not been in the focus of research yet.
A blood loss simulation study containing four "bleeding" scenarios each per sponge colour were created by using expired whole blood donation samples. The blood donations were applied to white and green surgical sponges after dilution with full electrolyte solution. Study participants had to estimate the absorbed blood loss in sponges in all scenarios. The difference to the reference blood loss was analysed. Multivariate linear regression analysis was performed to investigate other influence factors such as staff experience and sponge colour.
A total of 53 anaesthesists participated in the study. Visual estimation correlated moderately with reference blood loss in white (Spearman's rho: 0.521; p = 3.748*10-16) and green sponges (Spearman's rho: 0.452; p = 4.683*10-12). The median visually estimated blood loss was higher in white sponges (250ml IRQ 150-412.5ml) than in green sponges (150ml IQR 100-300ml), compared to reference blood loss (103ml IQR 86-162.8). For both colour types of sponges, major under- and overestimation was observed. The multivariate statistics demonstrates that fabric colours have a significant influence on estimation (p = 3.04*10-10), as well as clinician's qualification level (p = 2.20*10-10, p = 1.54*10-08) and amount of RBL to be estimated (p < 2*10-16).
The deviation of correct blood loss estimation was smaller with white surgical sponges compared to green sponges. In general, deviations were so severe for both types of sponges, that it appears to be advisable to refrain from visually estimating blood loss whenever possible and instead to use other techniques such as e.g. colorimetric estimation.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Dysphagia is a frequent symptom in acute ischemic stroke (AIS). Endovascular treatment (EVT) has become the standard of care for acute stroke secondary to large vessel occlusion. Although ...standardized guidelines for poststroke dysphagia (PSD) management exist, they do not account for this setting in which patients receive EVT under general anesthesia. Therefore, the aim of this study was to evaluate PSD prevalence and severity, as well as an appropriate time point for the PSD evaluation, in patients undergoing EVT under general anesthesia (GA).
We prospectively included 54 AIS patients undergoing EVT under GA. Fiberoptic Endoscopic Evaluation of Swallowing (FEES) was performed within 24 h post-extubation in all patients. Patients presenting significant PSD received a second FEES-assessment to determine the course of dysphagia deficits over time. Dysphagia severity was rated according the Fiberoptic Dysphagia Severity Scale (FEDSS).
At first FEES (FEES 1) assessment, performed in the median 13 h (IQR 5-17) post-extubation, 49/54 patients (90.7%) with dysphagia were observed with a median FEDSS of 4 (IQR 3-6). Severe dysphagia requiring tube feeding was identified in 28/54 (51.9%) subjects, whereas in 21 (38.9%) patients early oral diet with certain food restrictions could be initiated. In the follow up FEES examination conducted in the median 72 h (IQR 70-97 h) after initial FEES 34/49 (69.4%) patients still presented PSD. Age (
= 0.030) and ventilation time (
= 0.035) were significantly associated with the presence of PSD at the second FEES evaluation. Significant improvement of dysphagia frequency (
= 0.006) and dysphagia severity (
= 0.001) could be detected between the first and second dysphagia assessment.
PSD is a frequent finding both immediately within 24 h after extubation, as well as in the short-term course. In contrast to common clinical practice, to delay evaluation of swallowing for at least 24 h post-extubation, we recommend a timely assessment of swallowing function after extubation, as 50% of patients were safe to begin oral intake. Given the high amount of severe dysphagic symptoms, we strongly recommend application of instrumental swallowing diagnostics due to its higher sensitivity, when compared to clinical swallowing examination. Furthermore, advanced age, as well as prolonged intubation, were identified as significant predictors for delayed recovery of swallowing function.
The
intrapartum treatment (EXIT) allows to ensure fetal airway while keeping uteroplacental circulation. However, EXIT may become a life-threatening procedure due to the increased risk of uterine ...atony or placenta abruption with increased peripartum blood losses and increased transfusion rates. We aim to review maternal anemia prevalence and transfusion requirements in women undergoing EXIT procedure.
Using data from the Federal German Statistical Office hospitalized women undergoing EXIT procedure between January 1st 2006 and December 31st 2021 were included. The prevalence of anemia, peripartum hemorrhage, comorbidities and administration of red blood cells (RBC) were analyzed.
In total, 72 women underwent EXIT procedure with a median age of 31 years (26;33.5). In 43.1% EXIT was conducted at 34-36 weeks of gestational age. "Anemia during pregnancy" was present in 47.2%, "anemia due to acute bleeding" in 25.0% and "iron deficiency anemia" in 15.3%. Postpartum hemorrhage occurred in 11.1%. RBCs were transfused in 15.3% of all women. Most women required 1-5 units of RBCs.
Despite the rarity of this procedure, anemia management and blood conservation strategies in order to reduce the need for RBC transfusion are highly important in women undergoing EXIT procedure.
The most common technique used worldwide to quantify blood loss during an operation is the visual assessment by the attending intervention team. In every operating room you will find scaled suction ...canisters that collect fluids from the surgical field. This scaling is commonly used by clinicians for visual assessment of intraoperative blood loss. While many studies have been conducted to quantify and improve the inaccuracy of the visual estimation method, research has focused on the estimation of blood volume in surgical drapes. The question whether and how scaling of canisters correlates with actual blood loss and how accurately clinicians estimate blood loss in scaled canisters has not been the focus of research to date.
A simulation study with four "bleeding" scenarios was conducted using expired whole blood donations. After diluting the blood donations with full electrolyte solution, the sample blood loss volume (SBL) was transferred into suction canisters. The study participants then had to estimate the blood loss in all four scenarios. The difference to the reference blood loss (RBL) per scenario was analyzed.
Fifty-three anesthetists participated in the study. The median estimated blood loss was 500 ml (IQR 300/1150) compared to the RBL median of 281.5 ml (IQR 210.0/1022.0). Overestimations up to 1233 ml were detected. Underestimations were also observed in the range of 138 ml. The visual estimate for canisters correlated moderately with RBL (Spearman's rho: 0.818; p < 0.001). Results from univariate nonparametric confirmation statistics regarding visual estimation of canisters show that the deviation of the visual estimate of blood loss is significant (z = - 10.95, p < 0.001, n = 220). Participants' experience level had no significant influence on VEBL (p = 0.402).
The discrepancies between the visual estimate of canisters and the actual blood loss are enormous despite the given scales. Therefore, we do not recommend estimating the blood loss visually in scaled suction canisters. Colorimetric blood loss estimation could be a more accurate option.