Optical communication technology has been advancing rapidly for several decades, supporting our increasingly information-driven society and economy. Much of this progress has been in finding ...innovative ways to increase the data-carrying capacity of a single optical fibre. To achieve this, researchers have explored and attempted to optimize multiplexing in time, wavelength, polarization and phase. Commercial systems now utilize all four dimensions to send more information through a single fibre than ever before. The spatial dimension has, however, remained untapped in single fibres, despite it being possible to manufacture fibres supporting hundreds of spatial modes or containing multiple cores, which could be exploited as parallel channels for independent signals.
Thermosets-polymeric materials that adopt a permanent shape upon curing-have a key role in the modern plastics and rubber industries, comprising about 20 per cent of polymeric materials manufactured ...today, with a worldwide annual production of about 65 million tons
. The high density of crosslinks that gives thermosets their useful properties (for example, chemical and thermal resistance and tensile strength) comes at the expense of degradability and recyclability. Here, using the industrial thermoset polydicyclopentadiene as a model system, we show that when a small number of cleavable bonds are selectively installed within the strands of thermosets using a comonomer additive in otherwise traditional curing workflows, the resulting materials can display the same mechanical properties as the native material, but they can undergo triggered, mild degradation to yield soluble, recyclable products of controlled size and functionality. By contrast, installation of cleavable crosslinks, even at much higher loadings, does not produce degradable materials. These findings reveal that optimization of the cleavable bond location can be used as a design principle to achieve controlled thermoset degradation. Moreover, we introduce a class of recyclable thermosets poised for rapid deployment.
Incompatible live donor kidney transplantation (ILDKT) offers a survival advantage over dialysis to patients with anti‐HLA donor‐specific antibody (DSA). Program‐specific reports (PSRs) fail to ...account for ILDKT, placing this practice at regulatory risk. We collected DSA data, categorized as positive Luminex, negative flow crossmatch (PLNF) (n = 185), positive flow, negative cytotoxic crossmatch (PFNC) (n = 536) or positive cytotoxic crossmatch (PCC) (n = 304), from 22 centers. We tested associations between DSA, graft loss and mortality after adjusting for PSR model factors, using 9669 compatible patients as a comparison. PLNF patients had similar graft loss; however, PFNC (adjusted hazard ratio aHR = 1.64, 95% confidence interval CI: 1.15–2.23, p = 0.007) and PCC (aHR = 5.01, 95% CI: 3.71–6.77, p < 0.001) were associated with increased graft loss in the first year. PLNF patients had similar mortality; however, PFNC (aHR = 2.04; 95% CI: 1.28–3.26; p = 0.003) and PCC (aHR = 4.59; 95% CI: 2.98–7.07; p < 0.001) were associated with increased mortality. We simulated Centers for Medicare & Medicaid Services flagging to examine ILDKT's effect on the risk of being flagged. Compared to equal‐quality centers performing no ILDKT, centers performing 5%, 10% or 20% PFNC had a 1.19‐, 1.33‐ and 1.73‐fold higher odds of being flagged. Centers performing 5%, 10% or 20% PCC had a 2.22‐, 4.09‐ and 10.72‐fold higher odds. Failure to account for ILDKT's increased risk places centers providing this life‐saving treatment in jeopardy of regulatory intervention.
In this 22‐center study of HLA‐incompatible live donor kidney transplants (ILDKT), the authors demonstrate the increased risk of graft loss and death associated with increasing anti‐HLA donor‐specific antibody strength, and they quantify the significantly increased risk of flagging for regulatory scrutiny by the Centers for Medicare & Medicaid Studies that is incurred by centers that perform ILDKT. See editorial by Cole and Tinckam on page 1475.
CONTEXT: The urban heat island (UHI) is a well-documented pattern of warming in cities relative to rural areas. Most UHI research utilizes remote sensing methods at large scales, or climate sensors ...in single cities surrounded by standardized land cover. Relatively few studies have explored continental-scale climatic patterns within common urban microenvironments such as residential landscapes that may affect human comfort. OBJECTIVES: We tested the urban homogenization hypothesis which states that structure and function in cities exhibit ecological “sameness” across diverse regions relative to the native ecosystems they replaced. METHODS: We deployed portable micrometeorological sensors to compare air temperature and humidity in residential yards and native landscapes across six U.S. cities that span a range of climates (Phoenix, AZ; Los Angeles, CA; Minneapolis-St. Paul, MN; Boston, MA; Baltimore, MD; and Miami, FL). RESULTS: Microclimate in residential ecosystems was more similar among cities than among native ecosystems, particularly during the calm morning hours. Maximum regional actual evapotranspiration (AET) was related to the morning residential microclimate effect. Residential yards in cities with maximum AET <50–65 cm/year (Phoenix and Los Angeles) were generally cooler and more humid than nearby native shrublands during summer mornings, while yards in cities above this threshold were generally warmer (Baltimore and Miami) and drier (Miami) than native forests. On average, temperature and absolute humidity were ~6 % less variable among residential ecosystems than among native ecosystems from diverse regions. CONCLUSIONS: These data suggest that common residential land cover and structural characteristics lead to microclimatic convergence across diverse regions at the continental scale.
The Jupiter Energetic Particle Detector Instruments (JEDI) on the Juno Jupiter polar-orbiting, atmosphere-skimming, mission to Jupiter will coordinate with the several other space physics instruments ...on the Juno spacecraft to characterize and understand the space environment of Jupiter’s polar regions, and specifically to understand the generation of Jupiter’s powerful aurora. JEDI comprises 3 nearly-identical instruments and measures at minimum the energy, angle, and ion composition distributions of ions with energies from H:20 keV and O: 50 keV to >1 MeV, and the energy and angle distribution of electrons from <40 to >500 keV. Each JEDI instrument uses microchannel plates (MCP) and thin foils to measure the times of flight (TOF) of incoming ions and the pulse height associated with the interaction of ions with the foils, and it uses solid state detectors (SSD’s) to measure the total energy (
E
) of both the ions and the electrons. The MCP anodes and the SSD arrays are configured to determine the directions of arrivals of the incoming charged particles. The instruments also use fast triple coincidence and optimum shielding to suppress penetrating background radiation and incoming UV foreground. Here we describe the science objectives of JEDI, the science and measurement requirements, the challenges that the JEDI team had in meeting these requirements, the design and operation of the JEDI instruments, their calibrated performances, the JEDI inflight and ground operations, and the initial measurements of the JEDI instruments in interplanetary space following the Juno launch on 5 August 2011. Juno will begin its prime science operations, comprising 32 orbits with dimensions 1.1×40 RJ, in mid-2016.
The Radiation Belt Storm Probes Ion Composition Experiment (RBSPICE) on the two Van Allen Probes spacecraft is the magnetosphere ring current instrument that will provide data for answering the three ...over-arching questions for the Van Allen Probes Program: RBSPICE will determine “how space weather creates the storm-time ring current around Earth, how that ring current supplies and supports the creation of the radiation belt populations,” and how the ring current is involved in radiation belt losses. RBSPICE is a time-of-flight versus total energy instrument that measures ions over the energy range from ∼20 keV to ∼1 MeV. RBSPICE will also measure electrons over the energy range ∼25 keV to ∼1 MeV in order to provide instrument background information in the radiation belts. A description of the instrument and its data products are provided in this chapter.
Climate challenges, vulnerabilities, and food security Nelson, Margaret C.; Ingram, Scott E.; Dugmore, Andrew J. ...
Proceedings of the National Academy of Sciences - PNAS,
01/2016, Letnik:
113, Številka:
2
Journal Article
Recenzirano
Odprti dostop
This paper identifies rare climate challenges in the long-term history of seven areas, three in the subpolar North Atlantic Islands and four in the arid-to-semiarid deserts of the US Southwest. For ...each case, the vulnerability to food shortage before the climate challenge is quantified based on eight variables encompassing both environmental and social domains. These data are used to evaluate the relationship between the “weight” of vulnerability before a climate challenge and the nature of social change and food security following a challenge. The outcome of this work is directly applicable to debates about disaster management policy.
PI3K (phosphoinositide 3-kinase)/AKT and RAS/MAPK (mitogen-activated protein kinase) pathway coactivation in the prostate epithelium promotes both epithelial-mesenchymal transition (EMT) and ...metastatic castration-resistant prostate cancer (mCRPC), which is currently incurable. To study the dynamic regulation of the EMT process, we developed novel genetically defined cellular and in vivo model systems from which epithelial, EMT and mesenchymal-like tumor cells with Pten deletion and Kras activation can be isolated. When cultured individually, each population has the capacity to regenerate all three tumor cell populations, indicative of epithelial-mesenchymal plasticity. Despite harboring the same genetic alterations, mesenchymal-like tumor cells are resistant to PI3K and MAPK pathway inhibitors, suggesting that epigenetic mechanisms may regulate the EMT process, as well as dictate the heterogeneous responses of cancer cells to therapy. Among differentially expressed epigenetic regulators, the chromatin remodeling protein HMGA2 is significantly upregulated in EMT and mesenchymal-like tumors cells, as well as in human mCRPC. Knockdown of HMGA2, or suppressing HMGA2 expression with the histone deacetylase inhibitor LBH589, inhibits epithelial-mesenchymal plasticity and stemness activities in vitro and markedly reduces tumor growth and metastasis in vivo through successful targeting of EMT and mesenchymal-like tumor cells. Importantly, LBH589 treatment in combination with castration prevents mCRPC development and significantly prolongs survival following castration by enhancing p53 and androgen receptor acetylation and in turn sensitizing castration-resistant mesenchymal-like tumor cells to androgen deprivation therapy. Taken together, these findings demonstrate that cellular plasticity is regulated epigenetically, and that mesenchymal-like tumor cell populations in mCRPC that are resistant to conventional and targeted therapies can be effectively treated with the epigenetic inhibitor LBH589.
The Energetic Particle Detector (EPD) Investigation is one of 5 fields-and-particles investigations on the Magnetospheric Multiscale (MMS) mission. MMS comprises 4 spacecraft flying in close ...formation in highly elliptical, near-Earth-equatorial orbits targeting understanding of the fundamental physics of the important physical process called magnetic reconnection using Earth’s magnetosphere as a plasma laboratory. EPD comprises two sensor types, the Energetic Ion Spectrometer (EIS) with one instrument on each of the 4 spacecraft, and the Fly’s Eye Energetic Particle Spectrometer (FEEPS) with 2 instruments on each of the 4 spacecraft. EIS measures energetic ion energy, angle and elemental compositional distributions from a required low energy limit of 20 keV for protons and 45 keV for oxygen ions, up to >0.5 MeV (with capabilities to measure up to >1 MeV). FEEPS measures instantaneous all sky images of energetic electrons from 25 keV to >0.5 MeV, and also measures total ion energy distributions from 45 keV to >0.5 MeV to be used in conjunction with EIS to measure all sky ion distributions. In this report we describe the EPD investigation and the details of the EIS sensor. Specifically we describe EPD-level science objectives, the science and measurement requirements, and the challenges that the EPD team had in meeting these requirements. Here we also describe the design and operation of the EIS instruments, their calibrated performances, and the EIS in-flight and ground operations. Blake et al. (The Flys Eye Energetic Particle Spectrometer (FEEPS) contribution to the Energetic Particle Detector (EPD) investigation of the Magnetospheric Magnetoscale (MMS) Mission,
this issue
) describe the design and operation of the FEEPS instruments, their calibrated performances, and the FEEPS in-flight and ground operations. The MMS spacecraft will launch in early 2015, and over its 2-year mission will provide comprehensive measurements of magnetic reconnection at Earth’s magnetopause during the 18 months that comprise orbital phase 1, and magnetic reconnection within Earth’s magnetotail during the about 6 months that comprise orbital phase 2.
We report a two-span, 67-km space-division-multiplexed (SDM) wavelength-division-multiplexed (WDM) system incorporating the first reconfigurable optical add-drop multiplexer (ROADM) supporting ...spatial superchannels and the first cladding-pumped multicore erbium-doped fiber amplifier directly spliced to multicore transmission fiber. The ROADM subsystem utilizes two conventional 1 × 20 wavelength selective switches (WSS) each configured to implement a 7 × (1 × 2) WSS. ROADM performance tests indicate that the subchannel insertion losses, attenuation accuracies, and passband widths are well matched to each other and show no significant penalty, compared to the conventional operating mode for the WSS. For 6 × 40 × 128-Gb/s SDM-WDM polarization-multiplexed quadrature phase-shift-keyed (PM-QPSK) transmission on 50 GHz spacing, optical signal-to-noise ratio penalties are less than 1.6 dB in Add, Drop, and Express paths. In addition, we demonstrate the feasibility of utilizing joint signal processing of subchannels in this two-span, ROADM system.