Observation time is the key parameter for improving the precision of measurements of gravitational quantum states of particles levitating above a reflecting surface. We propose a new method of long ...confinement in such states of atoms, anti-atoms, neutrons and other particles possessing a magnetic moment. The earth gravitational field and a reflecting mirror confine particles in the vertical direction. The magnetic field originating from electric current passing through a vertical wire confines particles in the radial direction. Under appropriate conditions, motions along these two directions are decoupled to a high degree. We estimate characteristic parameters of the problem, and list possible systematic effects that limit storage times due to the coupling of the two motions.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
We report on the first production of an antihydrogen beam by charge exchange of 6.1 keV antiprotons with a cloud of positronium in the GBAR experiment at CERN. The 100 keV antiproton beam delivered ...by the AD/ELENA facility was further decelerated with a pulsed drift tube. A 9 MeV electron beam from a linear accelerator produced a low energy positron beam. The positrons were accumulated in a set of two Penning–Malmberg traps. The positronium target cloud resulted from the conversion of the positrons extracted from the traps. The antiproton beam was steered onto this positronium cloud to produce the antiatoms. We observe an excess over background indicating antihydrogen production with a significance of 3–4 standard deviations.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
For the GBAR (Gravitational Behaviour of Antihydrogen at Rest) experiment at CERN’s Antiproton Decelerator (AD) facility we have constructed a source of slow positrons, which uses a low-energy ...electron linear accelerator (linac). The driver linac produces electrons of 9 MeV kinetic energy that create positrons from bremsstrahlung-induced pair production. Staying below 10 MeV ensures no persistent radioactive activation in the target zone and that the radiation level outside the biological shield is safe for public access. An annealed tungsten-mesh assembly placed directly behind the target acts as a positron moderator. The system produces 5×107 slow positrons per second, a performance demonstrating that a low-energy electron linac is a superior choice over positron-emitting radioactive sources for high positron flux.
This review explores genetic contributors to drug interactions, known as drug-gene and drug-drug-gene interactions (DGI and DDGI, respectively). This article is part of a mini-review issue led by the ...International Society for the Study of Xenobiotics (ISSX) New Investigators Group. Pharmacogenetics (PGx) is the study of the impact of genetic variation on pharmacokinetics (PK), pharmacodynamics (PD), and adverse drug reactions. Genetic variation in pharmacogenes, including drug metabolizing enzymes and drug transporters, is common and can increase the risk of adverse drug events or contribute to reduced efficacy. In this review, we summarize clinically actionable genetic variants, and touch on methodologies such as genotyping patient DNA to identify genetic variation in targeted genes, and deep mutational scanning as a high-throughput in vitro approach to study the impact of genetic variation on protein function and/or expression in vitro. We highlight the utility of physiologically based pharmacokinetic (PBPK) models to integrate genetic and chemical inhibitor and inducer data for more accurate human PK simulations. Additionally, we analyze the limitations of historical ethnic descriptors in pharmacogenomics research. Altogether, the work herein underscores the importance of identifying and understanding complex DGI and DDGIs with the intention to provide better treatment outcomes for patients. We also highlight current barriers to wide-scale implementation of PGx-guided dosing as standard or care in clinical settings.This review explores genetic contributors to drug interactions, known as drug-gene and drug-drug-gene interactions (DGI and DDGI, respectively). This article is part of a mini-review issue led by the International Society for the Study of Xenobiotics (ISSX) New Investigators Group. Pharmacogenetics (PGx) is the study of the impact of genetic variation on pharmacokinetics (PK), pharmacodynamics (PD), and adverse drug reactions. Genetic variation in pharmacogenes, including drug metabolizing enzymes and drug transporters, is common and can increase the risk of adverse drug events or contribute to reduced efficacy. In this review, we summarize clinically actionable genetic variants, and touch on methodologies such as genotyping patient DNA to identify genetic variation in targeted genes, and deep mutational scanning as a high-throughput in vitro approach to study the impact of genetic variation on protein function and/or expression in vitro. We highlight the utility of physiologically based pharmacokinetic (PBPK) models to integrate genetic and chemical inhibitor and inducer data for more accurate human PK simulations. Additionally, we analyze the limitations of historical ethnic descriptors in pharmacogenomics research. Altogether, the work herein underscores the importance of identifying and understanding complex DGI and DDGIs with the intention to provide better treatment outcomes for patients. We also highlight current barriers to wide-scale implementation of PGx-guided dosing as standard or care in clinical settings.
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from ...scattering and regular hydrogen spectroscopy.
Positron accumulation in the GBAR experiment Blumer, P.; Charlton, M.; Chung, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/2022, Letnik:
1040
Journal Article
Recenzirano
Odprti dostop
We present a description of the GBAR positron (e+) trapping apparatus, which consists of a three stage Buffer Gas Trap (BGT) followed by a High Field Penning Trap (HFT), and discuss its performance. ...The overall goal of the GBAR experiment is to measure the acceleration of the neutral antihydrogen (H¯) atom in the terrestrial gravitational field by neutralising a positive antihydrogen ion (H¯+), which has been cooled to a low temperature, and observing the subsequent H¯ annihilation following free fall. To produce one H¯+ ion, about 1010 positrons, efficiently converted into positronium (Ps), together with about 107 antiprotons (p¯), are required. The positrons, produced from an electron linac-based system, are accumulated first in the BGT whereafter they are stacked in the ultra-high vacuum HFT, where we have been able to trap 1.4(2) × 109 positrons in 1100 s.
This article reports the first optical frequency measurement of the 1S–3S transition in hydrogen. The excitation of this transition occurs at a wavelength of 205 nm which is obtained with two ...frequency doubling stages of a titanium sapphire laser at 820 nm. Its frequency is measured with an optical frequency comb. The second-order Doppler effect is evaluated from the observation of the motional Stark effect due to a transverse magnetic field perpendicular to the atomic beam. The measured value of the
(
F
= 1)-3S
1/2
(
F
= 1) frequency splitting is 2 922 742 936.729(13) MHz with a relative uncertainty of 4.5 × 10
-12
. After the measurement of the 1S–2S frequency, this result is the most precise of the optical frequencies in hydrogen.