The pollen tube is the most rapidly growing cell in the plant kingdom and has the function to deliver the sperm cells for fertilization. The growing tip region of the cell behaves in a chemotropic ...manner to respond to the guidance cues emitted by the pistil and the female gametophyte, but how it perceives and responds to these directional triggers is virtually unknown. Quantitative assessment of chemotropic behavior can greatly be enhanced by the administration of pharmacological or other biologically active agents at subcellular precision, which is a technical challenge when the target area moves as it grows. We developed a laminar flow based microfluidic device that allows for continuous administration of two different solutions with a movable interface that permits the dynamic targeting of the growing pollen tube apex over prolonged periods of time. Asymmetric administration of calcium revealed that rather than following the highest calcium concentration as would be expected with simple chemotropic behavior, the pollen tube of Camellia targets an optimal concentration suggesting the presence of two superimposed mechanisms. Subcellular application of pectin methyl esterase (PME), an enzyme that modifies the growth behavior by rigidifying the pollen tube cell wall, caused the tube to turn away from the agent – providing important evidence for a previously proposed conceptual model of the growth mechanism.
Nanofluids have extensive applications in hydrodynamic journal bearings used in heavy industry machinery. Inorganic fullerene-like tungsten disulfide nanoparticles (IF-WS2 NPs) are the most common ...additive for lubrication purpose due to their excellent mechanical characteristics along with their effect on reducing friction and wear. In this work, a computational simulation approach with discrete phase modeling (DPM) of suspended nanoparticles was used to evaluate the application of the IF-WS2 nanofluid lubricant on load carrying capacity of high-load journal bearings where the normal loads are high, considering the bearing dimensions. For accurate simulation, nanofluid viscosity was calculated considering the aggregation effect of NPs by using scanning electron microscopy (SEM) imaging of the nanofluids. A benchmark study was first performed to assess the model accuracy. Hydrodynamic lubrication was simulated under different nanofluid weigh fractions. The simulated pressure distribution was then employed to determine the load capacity of the bearing. The results show an approximately 20% improvement of load carrying capacity at 5% weight fraction of WS2-oil nanofluid.
Microfluidic chemical gradient generators enable precise spatiotemporal control of chemotactic signals to study cellular behavior with high resolution and reliability. However, time and cost ...consuming preparation steps for cell adhesion in microchannels as well as requirement of pumping facilities usually complicate the application of the microfluidic assays. Here, we introduce a simple strategy for preparation of a reusable and stand-alone microfluidic gradient generator to study cellular behavior. Polydimethylsiloxane (PDMS) is directly mounted on the commercial polystyrene-based cell culture surfaces by manipulating the PDMS curing time to optimize bonding strength. The stand-alone strategy not only offers pumpless application of this microfluidic device but also ensures minimal fluidic pressure and consequently a leakage-free system. Elimination of any surface treatment or coating significantly facilitates the preparation of the microfluidic assay and offers a detachable PDMS microchip which can be reused following to a simple cleaning and sterilization step. The chemotactic signal in our microchip is further characterized using numerical and experimental evaluations and it is demonstrated that the device can generate both linear and polynomial signals. Finally, the feasibility of the strategy in deciphering cellular behavior is demonstrated by exploring cancer cell migration and invasion in response to chemical stimuli. The introduced strategy can significantly decrease the complexity of the microfluidic chemotaxis assays and increase their throughput for various cellular and molecular studies.
Characterizing the thermal behavior of dispersed droplets within microfluidic channels is crucial for different applications in lab-on-a-chip. In this paper, the physics of droplets volume during ...their transport over a heater is studied experimentally and numerically. The response of droplets to external heating is examined at temperature ranges of 25-90 °C and at different flow rates of the dispersed phase respect to the continuous flow. The results present a reliable prediction of the droplet volume and stability when heating is applied to the droplets at the downstream channel in a quite far distance from the droplets' ejection orifice. Increasing the ratio of flow rate resulted in larger droplets; for instance, the flow ratio of 0.25 produced drops with 40% larger diameter than the flow rate of 0.1. For every 10 °C increase in temperature of the droplets, the droplet diameter increased by about 5.7% and 4.2% for pure oil and oil with a surfactant, respectively. Also, the droplets showed a degree of instability during their transport over the heater at higher temperatures. Adding SPAN 20 surfactant improved the stability of the droplets at temperatures higher than 60 °C. The experimentally validated numerical model helped for systemic analysis of the influence of key temperature-dependence parameters (e.g. surface tension, density and viscosity of both phases) on controlling the volume and stability of droplets. Our findings supported to develop highly functional systems with a predetermined droplets performance under high temperatures up to 90 °C. This report provides a preliminary basis for enhancing the performance of droplet microfluidic systems for digital droplet polymerase chain reaction (ddPCR), continuous flow digital loop-mediated isothermal PCR (LAMP), and droplet-based antibiotic susceptibility testing.
Acoustophoretic microfluidic devices have been developed for accurate, label-free, contactless, and non-invasive manipulation of bioparticles in different biofluids. However, their widespread ...application is limited due to the need for the use of high quality microchannels made of materials with high specific acoustic impedances relative to the fluid (e.g., silicon or glass with small damping coefficient), manufactured by complex and expensive microfabrication processes. Soft polymers with a lower fabrication cost have been introduced to address the challenges of silicon- or glass-based acoustophoretic microfluidic systems. However, due to their small acoustic impedance, their efficacy for particle manipulation is shown to be limited. Here, we developed a new acoustophoretic microfluid system fabricated by a hybrid sound-hard (aluminum) and sound-soft (polydimethylsiloxane polymer) material. The performance of this hybrid device for manipulation of bead particles and cells was compared to the acoustophoretic devices made of acoustically hard materials. The results show that particles and cells in the hybrid material microchannel travel to a nodal plane with a much smaller energy density than conventional acoustic-hard devices but greater than polymeric microfluidic chips. Against conventional acoustic-hard chips, the nodal line in the hybrid microchannel could be easily tuned to be placed in an off-center position by changing the frequency, effective for particle separation from a host fluid in parallel flow stream models. It is also shown that the hybrid acoustophoretic device deals with smaller temperature rise which is safer for the actuation of bioparticles. This new device eliminates the limitations of each sound-soft and sound-hard materials in terms of cost, adjusting the position of nodal plane, temperature rise, fragility, production cost and disposability, making it desirable for developing the next generation of economically viable acoustophoretic products for ultrasound particle manipulation in bioengineering applications.
Invasive behaviour is the hallmark of a variety of cell types of animal, plant, and fungal origin. Here we review the purpose and mechanism of invasive growth and migration. The focus is on the ...physical principles governing the process, the source of invasive force, and the cellular mechanism by which the cell penetrates the substrate. The current experimental methods for measuring invasive force and the modelling approaches for studying invasive behaviour are explained, and future experimental strategies are proposed.
Summary
Large‐scale phenotyping of tip‐growing cells such as pollen tubes has hitherto been limited to very crude parameters such as germination percentage and velocity of growth. To enable efficient ...and high‐throughput execution of more sophisticated assays, an experimental platform, the TipChip, was developed based on microfluidic and microelectromechanical systems (MEMS) technology. The device allows positioning of pollen grains or fungal spores at the entrances of serially arranged microchannels equipped with microscopic experimental set‐ups. The tip‐growing cells (pollen tubes, filamentous yeast or fungal hyphae) may be exposed to chemical gradients, microstructural features, integrated biosensors or directional triggers within the modular microchannels. The device is compatible with Nomarski optics and fluorescence microscopy. Using this platform, we were able to answer several outstanding questions on pollen tube growth. We established that, unlike root hairs and fungal hyphae, pollen tubes do not have a directional memory. Furthermore, pollen tubes were found to be able to elongate in air, raising the question of how and where water is taken up by the cell. The platform opens new avenues for more efficient experimentation and large‐scale phenotyping of tip‐growing cells under precisely controlled, reproducible conditions.
This work presents a microfluidic chip integrated with a microwave resonator sensor for real‐time and contactless detection of Escherichia coli bacteria concentration. The design is fabricated on a ...Rogers RT/duroid 5880 high‐frequency substrate and operates at 2.5 ∼ 2.6 GHz, in the ISM band, with an initial quality factor of 112. The presented sensor demonstrates resonant amplitude sensitivity of −0.01231 dB/log(OD600) and resonant frequency sensitivity of −56 kHz/log(OD600) for E. coli concentration in a constant pH of 7.5. To facilitate the analysis of the proposed structure, a lumped equivalent circuit is presented and simulated in ADS and proven accurate by both HFSS microwave simulations and experimental results.
Flow distributor located at the beginning of the micromachined pillar array column (PAC) has significant roles in uniform distribution of flow through separation channels and thus separation ...efficiency. Chip manufacturing artifacts, contaminated solvents, and complex matrix of samples may contribute to clogging of the microfabricated channels, affect the distribution of the sample, and alter the performance of both natural and engineered systems. An even fluid distribution must be achieved cross-sectionally through careful design of flow distributors and minimizing the sensitivity to clogging in order to reach satisfactory separation efficiency. Given the difficulty to investigate experimentally a high number of clogging conditions and geometries, this work exploits a computational fluid dynamic model to investigate the effect of various design parameters on the performance of flow distributors in equally spreading the flow along the separation channels in the presence of different degrees of clogging. An array of radially elongated hexagonal pillars was selected for the separation channel (column). The design parameters include channel width, distributor width, aspect ratio of the pillars, and number of contact zone rows. The performance of known flow distributors, including bifurcating (BF), radially interconnected (RI), and recently introduced mixed-mode (MM
) in addition to two new distributors designed in this work (MM
and MM
) were investigated in terms of mean elution time, volumetric variance, asymmetry factors, and pressure drop between the inlet and the monitor line for each design. The results show that except for pressure drop, the channel width and aspect ratio of the pillars has no significant influence on flow distribution pattern in non-clogged distributors. However, the behavior of flow distributors in response to clogging was found to be dependent on width of the channels. Also increasing the distributor width and number of contact zone rows after the first splitting stage showed no improvement in the ability to alleviate the clogging. MM
distributor with the channel width of 3 µm, aspect ratio of the pillars equal to 20, number of exits of 8, and number of contact zones of 3 exhibited the highest stability and minimum sensitivity to different degrees of clogging.
MicroRNAs (miRNAs) are small, endogenous, noncoding RNAs, shown to be expressed abnormally in many tumors and identified as predictive biomarkers for early diagnosis of several cancers including the ...breast. Therefore, the label-free and highly sensitive detection of miRNAs is of critical significance. In this work, a highly sensitive and label-free nano-genosensor is developed for the detection of miRNA-21, a known breast cancer biomarker, based on a specific architecture of nitrogen-doped functionalized graphene (NFG), silver nanoparticles (AgNPs), and polyaniline (PANI) that resulted in a remarkable effect on signal amplification. Following the successful functionalization of the nanocomposite and immobilization of the specific sequence of the aminated complementary oligonucleotide of miRNA-21, the detection was performed using differential pulse voltammetry (DPV). The oxidation peak current of the redox probe under optimal conditions was determined to monitor the event hybridization of miRNA-21 biomarker. Applying this highly sensitive and optimized nano-biosensor enabled detection of a wide dynamic range of 10 fM–10 µM with a sensitivity of 2.5 µA cm−2 and a low detection limit of 0.2 fM. This nano-biosensor also demonstrated highly reproducible results in the analysis of blood samples, with recoveries between 94% and 107%, and could be used for early detection of breast cancer by direct detection of the miRNA-21 in real clinical samples without any need to sample preparation, RNA extraction and/or amplification.
•Ultrasensitive nano-genosensor for detection of miRNA-21 as a promising breast cancer biomarker.•A label-free repeatable and reproducible nano-biosensor with a very wide linear range.•High recovery regarding to electrochemically sense miRNA-21 in blood as a real sample without any pretreatment.