Using a specially designed time-of-flight mass reflectron with a heating element inside the device, which makes it possible to heat solid samples and analyze the gases released from them, protective ...graphite tiles covering almost the entire plasma-facing surface of the Globus-M2 tokamak vacuum chamber were studied. Mass spectrometric analysis made it possible to determine the composition of the released gases to estimate their quantities, and thus to quantitatively characterize the quality of cleaning and degassing of tiles. It is shown that as a result of the applied method for processing tiles, the content of the light hydrogen isotope— protium, water, carbon monoxide and dioxide decreased several times, and the content of deuterium and helium isotopes decreased almost to zero.
The thermal energy stored in plasma
, normalized internal plasma inductance
and current beta
are calculated via the free-boundary equilibrium PET code. The equilibrium reconstruction algorithm is ...iterative method of minimizing two parameters, the distance between the reconstructed plasma boundary and that simulated by the PET code, as well as the difference between the plasma diamagnetic flux from PET and the experimental one. The discharges from the Globus-M2 tokamak with a toroidal magnetic field up to 0.9 T and a plasma current of 0.3–0.4 MA in a mode with auxiliary heating by two atomic injectors are analyzed. The possibility of using approximate formulas for estimating
and
is considered. The measured diamagnetic flux is used to determine
and then to calculate
. The normalized internal plasma inductance
is additionally determined from the measured vertical magnetic field under the assumption that
.
The diagnostic complex of the Globus-M2 spherical tokamak (
R
= 36 cm,
a
= 24 cm), the only operating tokamak in Russia with a divertor plasma configuration, which operates in the range of ...subthermonuclear temperatures (
T
e
to 1.6 keV,
T
i
to 4.5 keV) and densities (
n
e
to 2 × 10
20
m
–3
), is described. The Globus‑M2 tokamak is the unique scientific facility, which is a part of the Federal Center for Collective Use of the Ioffe Institute, Russian Academy of Sciences “Materials Science and Diagnostics in Advanced Technologies.” This allows third parties to perform their research using it. The work contains a list of all diagnostics currently available on the tokamak. The description of the diagnostics is structured in such a way that the reader gets an idea of their capabilities for measuring plasma parameters with an emphasis on the limits and accuracy of the measured values, and also spatial and time resolution. At the same time, many technical details are omitted in order to save space; references are given to papers with a more detailed description of individual diagnostics.
Divertor Thomson Scattering on Globus-M2 Ermakov, N. V.; Zhiltsov, N. S.; Kurskiev, G. S. ...
Plasma physics reports,
12/2023, Letnik:
49, Številka:
12
Journal Article
Recenzirano
We present the first Thomson scattering (TS) measurements of electron temperature in the lower divertor of the Globus-M2 tokamak. The divertor TS diagnostics is designed for local measurements of the
...T
e
(
z
,
t
) in the range of 1–100 eV and
n
e
(
z
,
t
) in the range of
m
–3
. Parameters of the probing Nd:YAG laser are as follows 1064 nm/2 J/100 Hz/3 ns. The probing chord is launched vertically at
R
= 24 cm and covers areas of the inner leg, vicinity of separatrix and private flux region. Along probing chord of 110 mm, 9 spatial points were realized. Advanced filter polychromators were used to analyze Thomson scattering spectra.
NBI-assisted plasma heating with one or two injectors of fast neutral atoms was studied at the Globus-M2 spherical tokamak at the toroidal magnetic fields of 0.8–0.9 T and plasma currents of 0.35–0.4 ...MA. Measurements of the spatial temperature and electron density distributions, performed using the Thomson scattering diagnostics, showed a twofold increase in heating of plasma electrons during the injection of neutral particles with energies of up to 45 keV at the beam power of 0.75 MW, as compared to the ohmic heating regime. Switching on the second additional beam with the particle energy of up to 30 keV and power of up to 0.5 MW resulted in obtaining the hot ion mode in the range of mean plasma densities of (1.6–10) × 10
19
m
−3
. According to the data of active spectroscopy and neutral particle analyzer diagnostics, in the hot zone, the ion temperature reached 4 keV at the plasma density of 8 × 10
19
m
−3
, which is more than 2.5 times higher than the electron temperature.
The diagnostic of the peripheral plasma parameters in terms of the relation of lines of neutral helium is included in the diagnostic complex of the tokamak Globus-M2. The first measurements of the ...peripheral plasma parameters are performed near the lower X point. The measured spatial distributions of the electron temperature and density are in satisfactory agreement with the simulation with the SOLPS-ITER code.
The results of measuring the electron temperature and density spatial distributions in plasma of the Globus-M2 tokamak using the Thomson scattering diagnostics are presented. The diagnostics provides ...measurements throughout the entire tokamak discharge, starting from time of gas breakdown. The Thomson scattering data were analyzed in order to determine the positions of the last closed flux surface, the plasma magnetic axis, and the radius of inversion during the saw-tooth oscillations. The results of measurements performed during the internal reconnection of magnetic field lines are presents, as well as the dynamics of spatial distributions of electron temperature, density and pressure during the plasma transition to the H-mode. The results of measuring the electron temperature distribution in the scrape-off layer using the Thomson scattering diagnostics are also presented for distances up to 4 cm outside the last closed flux surface.
At the compact spherical Globus-M2 tokamak, a series of experiments was conducted to study the effect of the injection of nitrogen on the discharge parameters. The experiments were carried out in ...discharges in deuterium in the divertor configuration, and the auxiliary heating was performed by deuterium neutral beam injection. During the nitrogen seeding, a substantial decrease in electron temperature near the divertor was recorded as well as a sharp decrease of the heat flux onto the divertor plate, while the density and temperature of the main plasma changed insignificantly. Simulations by the SOLPS-ITER showed a satisfactory agreement with the experiment.
Digital filter polychromator for Thomson scattering applications Kurskiev, G.S.; Chernakov, Al.P.; Solovey, V.A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
05/2020, Letnik:
963
Journal Article
Recenzirano
The paper describes the digital filter polychromator developed for Thomson scattering (TS) diagnostics. The device having ultra-low noise, high-speed detection system and up to 7 spectral channels is ...equipped with digitizer and single board computer for system control and data processing. The data acquisition system is capable to detect very short laser pulses of few ns width with low magnitude. This feature opens up new possibilities for the TS diagnostics design in modern fusion devices, which includes: operation with high background illumination, measurement of very low electron temperature and density at the plasma edge and scrape-off layer (SOL), separation of the TS signal and the stray light coming with a delay of several ns. The analysis of the TS signal waveform also gives a possibility to distinguish the TS and Mie scattering from the dust particles that is important for measurements in SOL. Owing to compactness and ultra-low energy consumption both optical and data processing units interfaced with optical Gigabit Ethernet were combined in a stand-alone device. Such all-in-one design with optical fiber input and optical digital output provides enhanced resistance to electromagnetic disturbances and simplify operation. A set of such polychromators can be mounted in a standard 19” rack and can be integrated with outer CODAC (Control, Data Access and Communication) system. Testing of the polychromators at the Globus-M2 tokamak has shown excellent performance of the developed serial devices.
First Globus-M2 Results Bakharev, N. N.; Balachenkov, I. M.; Chernyshev, F. V. ...
Plasma physics reports,
07/2020, Letnik:
46, Številka:
7
Journal Article
Recenzirano
Globus-M2—a new 1-Tesla spherical tokamak—was recently launched. The main features and research directions of this machine in scope of fusion–fission reactor development are described. Main results ...of the first experimental campaign with toroidal magnetic field up to 0.73 T and plasma current up to 0.33 MA are discussed. Significant improvement of the discharge parameters as compared to Globus-M was achieved. Plasma total stored energy higher than 7 kJ was obtained. Energy confinement time increase was consistent with predictions by spherical tokamak scalings. Toroidal Alfvén eigenmode-induced losses decrease with increase of plasma current and toroidal magnetic field. For the first time, LHCD with the toroidal wave slowing-down was successfully used at a spherical tokamak.