To quantitatively evaluate the retinal microvasculature in human subjects with retinal venous occlusions (RVO) using optical coherence tomography angiography (OCTA).
Retrospective, cross-sectional, ...observational case series.
Sixty subjects (84 eyes) were included (20 BRVO, 14 CRVO, 24 unaffected fellow eyes, and 26 controls).
OCTA was performed on a prototype, spectral domain-OCTA system in the 3x3mm central macular region. Custom software was used to quantify morphology and density of retinal capillaries using four quantitative parameters. The vasculature of the segmented retinal layers and nonsegmented whole retina were analyzed.
Fractal dimension (FD), vessel density (VD), skeletal density (SD), and vessel diameter index (VDI) within the segmented retinal layers and nonsegmented whole retina vasculature.
Nonsegmented analysis of RVO eyes demonstrated significantly lower FD (1.64±0.01 vs 1.715±0.002; p<0.001), VD (0.32±0.01 vs 0.432±0.002; p<0.001), and SD (0.073±0.004 vs 0.099±0.001; p<0.001) compared to controls. Compared to the fellow eye, FD, VD and SD were lower (p<0.001), and VDI was higher (p<0.001). FD, VD, and SD progressively decreased as the extent (or type) of RVO increased (control vs BRVO vs CRVO; p<0.001). In the unaffected fellow eye FD, VD and SD showed significant differences when compared to control eyes or affected RVO eyes (p<0.001).
Quantitative OCTA of the central 3x3mm macular region demonstrates significant differences in capillary density and morphology among subjects with BRVO and CRVO compared to controls or unaffected fellow eyes in all vascular layers. The unaffected fellow eyes also demonstrate significant differences when compared to controls. OCTA allows for noninvasive, layer-specific, quantitative evaluation of RVO-associated microvascular changes.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The Argus II Retinal Prosthesis System (Second Sight Medical Products, Inc, Sylmar, CA) was developed to restore some vision to patients blind as a result of retinitis pigmentosa (RP) or outer ...retinal degeneration. A clinical trial was initiated in 2006 to study the long-term safety and efficacy of the Argus II System in patients with bare or no light perception resulting from end-stage RP.
Prospective, multicenter, single-arm clinical trial. Within-patient controls included the nonimplanted fellow eye and patients' native residual vision compared with their vision with the Argus II.
Thirty participants in 10 centers in the United States and Europe.
The worse-seeing eye of blind patients was implanted with the Argus II. Patients wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina.
The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by 3 computer-based, objective tests. Secondary measures included functional vision performance on objectively scored real-world tasks.
Twenty-four of 30 patients remained implanted with functioning Argus II Systems at 5 years after implantation. Only 1 additional serious adverse event was experienced after the 3-year time point. Patients performed significantly better with the Argus II on than off on all visual function tests and functional vision tasks.
The 5-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind as a result of RP. The Argus II is the first and only retinal implant to have market approval in the European Economic Area, the United States, and Canada.
The most common microvascular complication of diabetes is diabetic retinopathy, the leading cause of blindness in adults of working age. Our understanding of the vascular changes in diabetic ...retinopathy was enhanced by the demonstration of fluorescein angiography (FA) in the human retina for the first time in 1961. It was subsequently integrated with digital fundoscopic imaging to become an invaluable technique in evaluation of the retinal vasculature. The recent development of OCT-angiography (OCT-A) has revolutionized the clinician’s ability to examine the retinal vasculature without the need for injection of a contrast dye. By coupling OCT, which can provide noninvasive cross-sectional imaging of the central retina, with angiography in OCT-A, one can reveal retinal perfusion by allowing visualization of the depth-resolved retinal capillary plexus. OCT-A has allowed for more precise delineation of changes in the retinal microvasculature, specifically the alterations of retinal vasculature and loss of capillary perfusion from chronic microvascular occlusion in diabetic retinopathy.
To quantitatively assess choriocapillaris (CC) flow deficits in eyes with diabetic retinopathy (DR) using swept-source optical coherence tomography angiography (SS-OCTA).
Diabetic subjects with ...different stages of DR and age-matched healthy subjects were recruited and imaged with SS-OCTA. The en face CC blood flow images were generated using previously published and validated algorithms. The percentage of CC flow deficits (FD%) and the mean CC flow deficit size were calculated in a 5-mm-diameter circle centered on the fovea from the 6×6-mm scans.
Forty-five diabetic subjects and 27 control subjects were included in the study. The CC FD% in diabetic eyes was on average 1.4-fold greater than in control eyes (12.34±4.14% vs 8.82±2.61%, P < 0.001). The mean CC FD size in diabetic eyes was on average 1.4-fold larger than in control eyes (2151.3± 650.8μm2 vs 1574.4±255.0 μm2, P < 0.001). No significant difference in CC FD% or mean CC FD size was observed between eyes with nonproliferative DR and eyes with proliferative DR (P = 1.000 and P = 1.000, respectively).
CC perfusion in DR can be objectively and quantitatively assessed with FD% and FD size. In the macular region, both CC FD% and CC FD size are increased in eyes with DR. SS-OCTA provides new insights for the investigations of CC perfusion status in diabetes in vivo.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Retinitis pigmentosa (RP) is a group of inherited retinal degenerations leading to blindness due to photoreceptor loss. Retinitis pigmentosa is a rare disease, affecting only approximately 100 000 ...people in the United States. There is no cure and no approved medical therapy to slow or reverse RP. The purpose of this clinical trial was to evaluate the safety, reliability, and benefit of the Argus II Retinal Prosthesis System (Second Sight Medical Products, Inc, Sylmar, CA) in restoring some visual function to subjects completely blind from RP. We report clinical trial results at 1 and 3 years after implantation.
The study is a multicenter, single-arm, prospective clinical trial.
There were 30 subjects in 10 centers in the United States and Europe. Subjects served as their own controls, that is, implanted eye versus fellow eye, and system on versus system off (native residual vision).
The Argus II System was implanted on and in a single eye (typically the worse-seeing eye) of blind subjects. Subjects wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina.
The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by 3 computer-based, objective tests.
A total of 29 of 30 subjects had functioning Argus II Systems implants 3 years after implantation. Eleven subjects experienced a total of 23 serious device- or surgery-related adverse events. All were treated with standard ophthalmic care. As a group, subjects performed significantly better with the system on than off on all visual function tests and functional vision assessments.
The 3-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind from RP. Earlier results from this trial were used to gain approval of the Argus II by the Food and Drug Administration and a CE mark in Europe. The Argus II System is the first and only retinal implant to have both approvals.
To associate detection of potential pathogen DNA in endophthalmitis with clinical outcomes.
Prospective cohort study.
Patients in whom endophthalmitis was diagnosed following an intraocular procedure ...were recruited. Clinical outcome data from baseline, week-1, month-1, and month-3 visits were collected. Intraocular biopsy samples were cultured by standard methods. Quantitative polymerase chain reaction (qPCR) was performed for specific pathogens and whole-genome sequencing (WGS).
A total of 50 patients (mean age 72 years old; 52% male) were enrolled. Twenty-four cases were culture-positive and 26 were culture-negative. WGS identified the cultured organism in 76% of culture-positive cases and identified potential pathogens in 33% of culture-negative cases. Month-1 and -3 visual acuities did not vary by pathogen-positive versus pathogen-negative cases as detected by either culture or WGS. Visual outcomes of Staphylococcus epidermidis endophthalmitis were no different than those of pathogen-negative cases, whereas the patients infected with other pathogens showed worse outcome. Higher baseline bacterial DNA loads of bacteria other than those of S epidermidis detected by WGS were associated with worse month-1 and -3 visual acuity, whereas the S epidermidis loads did not appear to influence outcomes. Torque teno virus (TTV) and Merkel cell polyomavirus (MCV) were detected by qPCR in 49% and 19% of cases, respectively. Presence of TTV at presentation was associated with a higher rate of secondary pars plana vitrectomy (P = .009) and retinal detachment (P = .022).
The presence and higher load of bacteria other than S epidermidis detected by WGS or DNA from TTV by qPCR in ocular fluids is associated with worse outcomes in post-procedure endophthalmitis.
Background
To characterize how prior incisional glaucoma surgery affects the intraocular pressure (IOP) elevation immediately following intravitreal anti-VEGF injections (IVI).
Methods
Single ...institution, experimental study. Patients with a history of incisional glaucoma surgery who were receiving anti-VEGF injections were recruited as well as control eyes. Pre- and post-injection IOP measurements were compared as well as time to recovery to within 5 and 10 mmHg of baseline IOP.
Results
Ten eyes with a history of glaucoma surgery and 29 control eyes receiving anti-VEGF injections were included. The most common indication for intravitreal anti-VEGF injection was proliferative diabetic retinopathy in both surgical and control eyes (50% vs 45%,
p
= 1.00). Post-injection IOP was significantly decreased compared to baseline IOP after anti-VEGF injection in surgical versus control eyes (26.5 ± 8.9 mmHg vs 44.2 ± 8.5 mmHg, respectively,
p
< 0.001). The mean change in IOP following intravitreal anti-VEGF injection was lower in surgical eyes (10.7 ± 6.6 mmHg vs 28.6 ± 8.3 mmHg,
p
< 0.001). The mean time for the IOP to return to within 10 mmHg of pre-injection IOP was less in surgical eyes (5.2 ± 4.1 min vs 13.3 ± 7.6 min,
p
= 0.002).
Conclusions
Eyes with prior incisional glaucoma surgery demonstrated a significantly lower post-injection IOP elevation and a faster recovery to within 10 mmHg of their pre-injection IOP. Incisional glaucoma surgery may be considered for patients where the attenuation of post-injection IOP elevation is needed and other less invasive measures have failed.
Background
The main objective of this study was to test Argus II subjects on three real‐world functional vision tasks.
Design
The study was designed to be randomized and prospective. Testing was ...conducted in a hospital/research laboratory setting at the various participating centres.
Participants
Twenty eight Argus II subjects, all profoundly blind, participated in this study.
Methods
Subjects were tested on the three real‐world functional vision tasks: Sock Sorting, Sidewalk Tracking and Walking Direction Discrimination task
Main Outcome Measures
For the Sock Sorting task, percentage correct was computed based on how accurately subjects sorted the piles on a cloth‐covered table and on a bare table. In the Sidewalk Tracking task, an ‘out of bounds’ count was recorded, signifying how often the subject veered away from the test course. During the Walking Direction Discrimination task, subjects were tested on the number of times they correctly identified the direction of testers walking across their field of view.
Results
The mean percentage correct OFF versus ON for the Sock Sorting task was found to be significantly different for both testing conditions (t‐test, P < 0.01). On the Sidewalk Tracking task, subjects performed significantly better with the system ON than they did with the system OFF (t‐test, P < 0.05). Eighteen (18) of 27 subjects (67%) performed above chance with the system ON, and 6 (22%) did so with system OFF on the Walking Direction Discrimination task.
Conclusions
Argus II subjects performed better on all three tasks with their systems ON than they did with their systems OFF.
To analyze and provide an overview of the incidence, management, and prevention of conjunctival erosion in Argus II clinical trial subjects and postapproval patients.
This retrospective analysis ...followed the results of 274 patients treated with the Argus II Retinal Prosthesis System between June 2007 and November 2017, including 30 subjects from the US and European clinical trials, and 244 patients in the postapproval phase. Results were gathered for incidence of a serious adverse event, incidence of conjunctival erosion, occurrence sites, rates of erosion, and erosion timing.
Overall, 60% of subjects in the clinical trial subjects versus 83% of patients in the postapproval phase did not experience device- or surgery-related serious adverse events. In the postapproval phase, conjunctival erosion had an incidence rate of 6.2% over 5 years and 11 months. In 55% of conjunctival erosion cases, erosion occurred in the inferotemporal quadrant, 25% in the superotemporal quadrant, and 20% in both. Sixty percent of the erosion events occurred in the first 15 months after implantation, and 85% within the first 2.5 years.
Reducing occurrence of conjunctival erosion in patients with the Argus II Retinal Prosthesis requires identification and minimization of risk factors before and during implantation. Implementing inverted sutures at the implant tabs, use of graft material at these locations as well as Mersilene rather than nylon sutures, and accurate Tenon's and conjunctiva closure are recommended for consideration in all patients.