Abstract Objectives This study sought to evaluate myocardial perfusion reserve index (MPRI) and diastolic strain rate, both assessed by cardiac magnetic resonance (CMR) as a noninvasive tool for the ...detection of microvasculopathy. Background Long-term survival of cardiac allograft recipients is limited primarily by cancer and cardiac allograft vasculopathy (CAV). Besides epicardial CAV, diagnosed by coronary angiography, stenotic microvasculopathy was found to be an additional independent risk factor for survival after heart transplantation. Methods Sixty-three consecutive heart transplant recipients who underwent CMR, coronary angiography, and myocardial biopsy were enrolled. Stenotic vasculopathy in microvessels was considered in myocardial biopsies by immunohistochemistry and CAV was graded during coronary angiography according to International Society of Heart and Lung Transplantation criteria. In addition, by CMR microvasculopathy was assessed by myocardial perfusion reserve during pharmacologic hyperemia with adenosine and strain-encoded magnetic resonance using a modified spatial modulation of magnetization tagging pulse sequence in all patients. Results Decreasing MPRI and diastolic strain rates were observed in patients with decreasing microvessel luminal radius to wall thickness ratio and decreasing capillary density ( r = 0.45 and r = 0.61 for MPRI and r = 0.50 and r = 0.38 for diastolic strain rate, respectively; p < 0.005 for all). Using multivariable analysis, both MPRI and diastolic strain rate were robust predictors of stenotic microvasculopathy, independent of age, organ age, and CAV by International Society of Heart and Lung Transplantation criteria (hazard ratio: 0.07, p = 0.006 for MPRI; hazard ratio: 0.91, p = 0.002 for diastolic strain rate). Patients without stenotic microvasculopathy in the presence of no or mild CAV (n = 36) exhibited significantly higher median survival free of events, compared with patients with stenotic microvasculopathy in the presence of no or mild CAV (n = 18; p = 0.04 by log rank). Conclusions CMR represents a valuable noninvasive diagnostic tool, which may be used for the early detection of transplant microvasculopathy before the manifestation of CAV during surveillance coronary angiographic procedures.
Objectives This study evaluated the value of systolic and diastolic deformation indexes determined by strain-encoded imaging to predict persistent severe dysfunction at follow-up in patients after ...reperfused acute myocardial infarction (AMI) in comparison with late gadolinium enhancement (LGE). Background Animal studies suggest that regional diastolic function provides information about myocardial viability after AMI. However, data in humans are sparse. Methods Twenty-six patients underwent magnetic resonance imaging 3 ± 1 days after successfully reperfused ST-segment elevation myocardial infarction and at a follow-up of 6 months. Cine, strain-encoded, and LGE images were acquired. Peak systolic circumferential strain (Ecc ) and early diastolic strain rate (Ecc /s) were calculated for each segment at baseline and at follow-up. A cutoff Ecc value of −9% was used to define severe dysfunction at follow-up. Results A total of 312 segments were analyzed; 119 segments showed abnormal baseline function. Thirty-five segments showed severe dysfunction at follow-up, which was defined as Ecc at follow-up <9%. The area under the curve for Ecc /s was 0.82 (95% confidence interval CI: 0.72 to 0.89), for Ecc 0.74 (95% CI: 0.64 to 0.83), and for LGE 0.85 (95% CI: 0.77 to 0.92). A comparison of receiver-operating characteristic curves demonstrates that LGE is not significantly different than Ecc /s but is significantly different than Ecc (p = 0.32 vs. p < 0.05) for prediction of severe dysfunction at follow-up. Conclusions Regional diastolic function provides similar accuracy to predict persistent severe dysfunction at follow-up to LGE and is superior to regional systolic function in patients after AMI. Diastolic deformation indexes may serve as a new parameter for assessment of viability in patients after AMI. (SENC in AMI Study; NCT00752713 ).
Diminished Left Ventricular Dyssynchrony and Impact of Resynchronization in Failing Hearts With Right Versus Left Bundle Branch Block Melissa J. Byrne, Robert H. Helm, Samantapudi Daya, Nael F. ...Osman, Henry R. Halperin, Ronald D. Berger, David A. Kass, Albert C. Lardo This study compares mechanical dyssynchrony and resynchronization in a dyssynchronous heart failure model of left (LBBB) and right bundle branch block (RBBB) using quantitative magnetic resonance imaging and acute hemodynamic measurements. Our results indicate that the degree of synchrony in RBBB is not significantly different than that of normal hearts and is substantially less than that of LBBB. While cardiac resynchronization therapy improved synchrony and function for both conditions, the overall improvement for RBBB was less pronounced. Lastly, biventricular and right-ventricular-only pacing equally resynchronized RBBB while left-ventricular-only pacing decreased function and synchrony.
Objectives This study sought to evaluate the diagnostic accuracy of strain-encoded cardiac magnetic resonance (SENC) for the detection of inducible ischemia during intermediate stress. Background ...High-dose dobutamine stress cardiac magnetic resonance (DS-CMR) is a well-established modality for the noninvasive detection of coronary artery disease (CAD). However, the assessment of cine scans relies on the visual interpretation of wall motion, which is subjective, and modalities that can objectively and quantitatively assess the time course of myocardial strain response during stress are lacking. Methods Stress-induced ischemia was assessed by wall motion analysis and by SENC in 80 patients with suspected or known CAD and in 18 healthy volunteers who underwent DS-CMR in a clinical 1.5-T scanner. Quantitative coronary angiography was used as the standard reference for the presence of CAD (≥50% diameter stenosis). Results On a patient level, 46 of 80 patients (58%) had CAD, including 20 with single-vessel, 18 with 2-vessel, and 8 with 3-vessel disease. During peak stress, SENC correctly detected ischemia in 45 versus 38 of 46 patients with CAD (7 additional correct findings for SENC), yielding significantly higher sensitivity than cine (98% vs. 83%, p < 0.05). No patients were correctly diagnosed by cine and missed by SENC. During intermediate stress, SENC showed diagnostic value similar to that provided by cine imaging only during peak dobutamine stress (sensitivity of 76% vs. 83%, specificity of 88% vs. 91%, and accuracy of 81% vs. 86%; p = NS for all). Quantification analysis demonstrated that strain rate response is a highly sensitive marker for the detection of inducible ischemia (area under the curve = 0.96; SE = 0.01; 95% confidence interval: 0.93 to 0.99) that precedes the development of inducible wall motion abnormalities and already significantly decreases with moderate 40% to 60% coronary lesions. Conclusions Using SENC, CAD can be detected during intermediate stress with similar accuracy to that provided by cine only during peak stress. By this approach, patient safety may be improved during diagnostic procedures within lower time spent (Strain-Encoded Cardiac Magnetic Resonance Imaging for Dobutamine Stress Testing; NCT00758654
Early detection of breast lesions using mammography has resulted in lower mortality rates. However, some breast lesions are mammography occult, and magnetic resonance imaging (MRI) is recommended, ...but it has lower specificity. It is possible to achieve higher specificity by using strain-encoded (SENC) MRI and/or magnetic resonance elastography. SENC breast MRI can measure the strain properties of breast tissue. Similarly, magnetic resonance elastography is used to measure the elasticity (ie, shear stiffness) of different tissue compositions interrogating the tissue mechanical properties. Reports have shown that malignant tumors are three to 13 times stiffer than normal tissue and benign tumors.
The investigators have developed a SENC breast hardware device capable of periodically compressing the breast, thus allowing for longer scanning time and measuring the strain characteristics of breast tissue. This hardware enables the use of SENC MRI with high spatial resolution (1 × 1 × 5 mm(3)) instead of fast SENC imaging. Simple controls and multiple safety measures were added to ensure accurate, repeatable, and safe in vivo experiments.
Phantom experiments showed that SENC breast MRI has higher signal-to-noise ratio and contrast-to-noise ratio than fast SENC imaging under different scanning resolutions. Finally, the SENC breast device reproducibility measurements resulted in a difference of <1 mm with a 1% strain difference.
SENC breast magnetic resonance images have higher signal-to-noise ratio and contrast-to-noise ratios than fast SENC images. Thus, combining SENC breast strain measurements with diagnostic breast MRI to differentiate benign from malignant lesions could potentially increase the specificity of diagnosis in the clinical setting.
Objectives The purpose of this study was to determine the prognostic value of strain-encoded magnetic resonance imaging (SENC) during high-dose dobutamine stress cardiac magnetic resonance imaging ...(DS-MRI) compared with conventional wall motion readings. Background Detection of inducible ischemia by DS-MRI on the basis of assessing cine images is subjective and depends on the experience of the readers, which may influence not only the diagnostic classification but also the risk stratification of patients with ischemic heart disease. Methods In all, 320 consecutive patients with suspected or known coronary artery disease underwent DS-MRI, using a standard protocol in a 1.5T MR scanner. Wall motion abnormalities (WMA) and myocardial strain were assessed at baseline and during stress, and outcome data including cardiac deaths, nonfatal myocardial infarctions (“hard events”), and revascularization procedures performed >90 days after the MR scans were collected. Results Thirty-five hard events occurred during a 28 ± 9 month follow-up period, including 10 cardiac deaths and 25 nonfatal myocardial infarctions, and 32 patients underwent coronary revascularization. Using a series of Cox proportional-hazards models, both resting and inducible WMA offered incremental information for the assessment of hard cardiac events compared to clinical variables (chi-square = 13.0 for clinical vs. chi-square = 26.1 by adding resting WMA, p < 0.001, vs. chi-square = 39.3 by adding inducible WMA, p < 0.001). Adding visual SENC or quantitative strain rate reserve to this model further improved the prediction of outcome (chi-square = 50.7 vs. chi-square = 52.5, p < 0.001 for both). In a subset of patients (n = 175) who underwent coronary angiography, SENC yielded significantly higher sensitivity for coronary artery disease detection (96% vs. 84%, p < 0.02), whereas specificity and accuracy were not significantly different (88% vs. 94% and 93% vs. 88%, p = NS for both). Conclusions Strain-encoded MRI aids the accurate identification of patients at high risk for future cardiac events and revascularization procedures, beyond the assessment of conventional atherogenic risk factors and resting or inducible WMA on cine images. (Strain-Encoded Cardiac Magnetic Resonance Imaging as an Adjunct for Dobutamine Stress Testing; NCT00758654 )