The R&D project COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches) aims to develop a cryogenic scintillating calorimeter using an undoped NaI-crystal as ...target for direct dark matter search. Dark matter particles interacting with the detector material generate both a phonon signal and scintillation light. While the phonon signal provides a precise determination of the deposited energy, the simultaneously measured scintillation light allows for particle identification on an event-by-event basis, a powerful tool to study material-dependent interactions, and to suppress backgrounds. Using the same target material as the DAMA/LIBRA collaboration, the COSINUS technique may offer a unique possibility to investigate and contribute information to the presently controversial situation in the dark matter sector. We report on the dedicated design planned for the NaI proof-of-principle detector and the objectives of using this detection technique in the light of direct dark matter detection.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Background model of the CUPID-0 experiment Azzolini, O.; Beeman, J. W.; Bellini, F. ...
The European physical journal. C, Particles and fields,
07/2019, Letnik:
79, Številka:
7
Journal Article
Recenzirano
Odprti dostop
CUPID-0 is the first large mass array of enriched Zn
82
Se scintillating low temperature calorimeters, operated at LNGS since 2017. During its first scientific runs, CUPID-0 collected an exposure of ...9.95 kg year. Thanks to the excellent rejection of
α
particles, we attained the lowest background ever measured with thermal detectors in the energy region where we search for the signature of
82
Se
neutrinoless double beta decay. In this work we develop a model to reconstruct the CUPID-0 background over the whole energy range of experimental data. We identify the background sources exploiting their distinctive signatures and we assess their extremely low contribution down to
∼
10
-
4
counts/(keV kg year) in the region of interest for
82
Se
neutrinoless double beta decay search. This result represents a crucial step towards the comprehension of the background in experiments based on scintillating calorimeters and in next generation projects such as CUPID.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
In the quest for direct dark matter detection, innovative approaches to lower the detection threshold and explore the sub-GeV mass range, have gained high relevance in the last decade. This study ...presents the pioneering use of Gallium Arsenide (GaAs) as a low-temperature calorimeter for probing dark matter-electron interactions within the DAREDEVIL (DARk-mattEr DEVIces for Low energy detection) project. Our experimental setup features a GaAs crystal at an ultralow temperature of 15 mK, coupled with a Neutron Transmutation Doped Germanium (NTD-Ge) thermal sensor for precise energy estimation. This configuration is the first step towards detecting single electrons scattered by dark matter particles within the GaAs crystal, to improve the sensitivity to low-mass dark matter candidates significantly. Taking advantage of the production of optical phonons in polar materials such as GaAs gives the possibility to study the scattering of sub-MeV dark matter. This paper presents a detailed analysis of the detector’s response, using a calibration spectrum using
α
particles and X-ray events. While the results do not meet the ambitious eV scale threshold yet, they establish a solid benchmark for assessing the detector’s current performance and sensitivity. This work not only highlights the detector’s potential but also sets the stage for future enhancements aimed at achieving the eV threshold, underscoring the promising direction of this detector technology. These findings demonstrate the feasibility of using GaAs as a cryogenic calorimeter and hence open new avenues for investigating the elusive nature of dark matter through innovative direct detection techniques.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
A
bstract
Neutrinoless double-beta decay is a key process in particle physics. Its experimental investigation is the only viable method that can establish the Majorana nature of neutrinos, providing ...at the same time a sensitive inclusive test of lepton number violation. CROSS (Cryogenic Rare-event Observatory with Surface Sensitivity) aims at developing and testing a new bolometric technology to be applied to future large-scale experiments searching for neutrinoless double-beta decay of the promising nuclei
100
Mo and
130
Te. The limiting factor in large-scale bolometric searches for this rare process is the background induced by surface radioactive contamination, as shown by the results of the CUORE experiment. The basic concept of CROSS consists of rejecting this challenging background component by pulse-shape discrimination, assisted by a proper coating of the faces of the crystal containing the isotope of interest and serving as energy absorber of the bolometric detector. In this paper, we demonstrate that ultra-pure superconductive Al films deposited on the crystal surfaces act successfully as pulse-shape modifiers, both with fast and slow phonon sensors. Rejection factors higher than 99.9% of
α
surface radioactivity have been demonstrated in a series of prototypes based on crystals of Li
2
MoO
4
and TeO
2
. We have also shown that point-like energy depositions can be identified up to a distance of
∼
1 mm from the coated surface. The present program envisions an intermediate experiment to be installed underground in the Canfranc laboratory (Spain) in a CROSS-dedicated facility. This experiment, comprising
∼
3
×
10
25
nuclei of
100
Mo, will be a general test of the CROSS technology as well as a worldwide competitive search for neutrinoless double-beta decay, with sensitivity to the effective Majorana mass down to 70 meV in the most favorable conditions.
The signal digitization for CROSS, a bolometric experiment for the search of neutrinoless double beta decay at LSC—Canfranc Underground Laboratory, will be based on a custom solution comprised of an ...analog-to-digital board interfaced to an Altera Cyclone V FPGA module. Each analog-to-digital board hosts 12 channels that allow data digitization up to 25 ksps per channel and an effective resolution of 21 bits at the typical sample rate required by the experiment (5 ksps). The board also allows to digitally select the cutoff frequency of the anti-aliasing filter with 10 bit resolution from 24 Hz up to 2.5 kHz, as required by fast scintillating bolometers. The FPGA is responsible for the synchronization of the analog-to-digital boards and for the data transfer to the storage, using UDP protocol on a standard Ethernet interface. Each FPGA can manage the data coming from eight boards (96 channels), allowing an excellent scalability. In this contribution, we will present a complete overview of the system and a detailed characterization of the system performance.
We present the first performance results obtained with microwave multiplexed Transition Edge Sensors prototypes specifically designed for the HOLMES experiment, a project aimed at directly measuring ...the electron neutrino mass through the calorimetric measurement of the
163
Ho electron capture spectrum. The detectors required for such an experiment feature a high energy resolution at the
Q
–value of the transition, around
∼
2.8 keV, and a fast response time combined with the compatibility to be multiplexed in large arrays in order to collect a large statistics while keeping the pile-up contribution as small as possible. In addition, the design has to be suitable for future ion-implantation of
163
Ho. The results obtained in these tests allowed us to identify the optimal detector design among several prototypes. The chosen detector achieved an energy resolution of (4.5 ± 0.3) eV on the chlorine K
α
line, at
∼
2.6 keV, obtained with an exponential rise time of 14
μ
s. The achievements described in this paper pose a milestone for the HOLMES detectors, setting a baseline for the subsequent developments, aiming to the actual ion-implantation of the
163
Ho nuclei. In the first section the HOLMES experiment is outlined along with its physics goal, while in the second section the HOLMES detectors are described; the experimental set-up and the calibration source used for the measurements described in this paper are reported in Sects.
3
and
4
, respectively; finally, the details of the data analysis and the results obtained are reported in Sect.
6
.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
CUORE is an array of thermal calorimeters composed of 988 crystals held at about 10 mK, whose absorbed energy is read out with semiconductor thermistors. The composition of the crystal is TeO2, and ...the aim is the study of the double beta decay of 130Te on very long and stable runs. CUPID-0 is an array of 26 Zn82Se crystals with double thermistor readout to study the double beta decay of 82Se. In the present paper, we present an overview of the entire front-end electronic readout chain, from the preamplifier to the anti-aliasing filter. This overview includes motivations, design strategies, circuit implementation and performance results of the electronic system, including other auxiliary yet important elements like power supplies and the slow control communication system. The stringent requirements of stability on the very long experimental runs that are foreseen during CUORE and CUPID-0 operation, are achieved thanks to novel solutions of the front-end preamplifier and of the detector bias circuit setup.
We present the performances of a 330 g zinc molybdate (ZnMoO
4
) crystal working as scintillating bolometer as a possible candidate for a next generation experiment to search for neutrinoless double ...beta decay of
100
Mo. The energy resolution, evaluated at the 2615 keV
γ
-line of
208
Tl, is 6.3 keV FWHM. The internal radioactive contaminations of the ZnMoO
4
were evaluated as <6 μBq/kg (
228
Th) and 27±6 μBq/kg (
226
Ra). We also present the results of the
α
vs
β
/
γ
discrimination, obtained through the scintillation light as well as through the study of the shape of the thermal signal alone.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Abstract
This paper reports on the time resolution of the Auratek-Square MCP-PMT, a multi-anode microchannel plate photomultiplier produced by Photek.
When operating as single photon counter at low ...photon rate and with a single pixel illuminated it shows a transit time spread (jitter) of ∼100 ps FWHM, saturating at high rate, above ∼100 kHz/mm
2
.
The worsening of the timing performance depends on the bias voltage between the photocathode and the MCP input and between the MCP slabs.
The charge sharing between neighbouring pixels can become a major crosstalk source if not accounted for, degrading the time resolution to ∼170 ps FWHM when the entire pixel area is illuminated.
The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of ...Formula: see textHo. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted Formula: see textHo nuclei. The resulting mass sensitivity will be as low as 0.4 eV. HOLMES will be an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. It will also establish the potential of this approach to extend the sensitivity down to 0.1 eV. We outline here the project with its technical challenges and perspectives.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK