Objectives This study sought to collect data and evaluate the anecdotal use of transcatheter aortic valve implantation (TAVI) in pure native aortic valve regurgitation (NAVR) for patients who were ...deemed surgically inoperable Background Data and experience with TAVI in the treatment of patients with pure severe NAVR are limited. Methods Data on baseline patient characteristics, device and procedure parameters, echocardiographic parameters, and outcomes up to July 2012 were collected retrospectively from 14 centers that have performed TAVI for NAVR. Results A total of 43 patients underwent TAVI with the CoreValve prosthesis (Medtronic, Minneapolis, Minnesota) at 14 centers (mean age, 75.3 ± 8.8 years; 53% female; mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation), 26.9 ± 17.9%; and mean Society of Thoracic Surgeons score, 10.2 ± 5.3%). All patients had severe NAVR on echocardiography without aortic stenosis and 17 patients (39.5%) had the degree of aortic valvular calcification documented on CT or echocardiography. Vascular access was transfemoral (n = 35), subclavian (n = 4), direct aortic (n = 3), and carotid (n = 1). Implantation of a TAVI was performed in 42 patients (97.7%), and 8 patients (18.6%) required a second valve during the index procedure for residual aortic regurgitation. In all patients requiring second valves, valvular calcification was absent (p = 0.014). Post-procedure aortic regurgitation grade I or lower was present in 34 patients (79.1%). At 30 days, the major stroke incidence was 4.7%, and the all-cause mortality rate was 9.3%. At 12 months, the all-cause mortality rate was 21.4% (6 of 28 patients). Conclusions This registry analysis demonstrates the feasibility and potential procedure difficulties when using TAVI for severe NAVR. Acceptable results may be achieved in carefully selected patients who are deemed too high risk for conventional surgery, but the possibility of requiring 2 valves and leaving residual aortic regurgitation remain important considerations.
Abstract Objectives The purpose of this analysis was to assess 5-year outcomes of transcatheter aortic valve implantation (TAVI) using the current technology of the self-expanding CoreValve ...prosthesis (Medtronic Inc., Minneapolis, Minnesota). Background There is a paucity of evidence on long-term durability of currently available transcatheter heart valves. Methods Starting in June 2007, all consecutive patients with severe aortic stenosis undergoing TAVI with the third-generation 18-F CoreValve device in 8 Italian centers were prospectively included in the ClinicalService Project. For the purposes of this study, we included only consecutive patients with 5-year follow-up data available (n = 353) treated from June 2007 to August 2009. All outcomes were reported according to VARC (Valve Academic Research Consortium)-1 criteria. Results All-cause mortality rates at 1, 2, 3, 4, and 5 years were 21%, 29%, 38%, 48%, and 55.0%, respectively. Cardiovascular mortality rates at 1, 2, 3, 4, and 5 years were 10%, 14%, 19%, 23%, and 28.0%, respectively. The overall neurological event rate at 5 years was 7.5%, of which more than two-thirds occurred early after the procedure. During follow-up, there were 241 rehospitalizations for cardiovascular reasons in 164 (46%) patients. Among all rehospitalizations, acute heart failure was the most frequently reported (42.7%), followed by requirement of permanent pacemaker implantation (17.4%). On echocardiography, mean transaortic gradients decreased from 55.6 ± 16.8 mm Hg (pre-TAVI) to 12.8 ± 10.9 mm Hg (5-year post-TAVI) (p < 0.001). Late prosthesis failure occurred in 5 cases (1.4%); among these, redo TAVI was successfully carried out in 2 patients (0.6%) presenting with symptomatic prosthesis restenosis. The remaining 3 cases of prosthesis failure did not undergo further invasive interventions. Ten patients (2.8%) showed late mild stenosis with a mean transaortic gradient ranging from 20 to 40 mm Hg. No other cases of structural or nonstructural valvular deterioration were observed. Valve thrombosis or late valve embolization were not reported. Conclusions TAVI with the currently adopted CoreValve generation was associated with sustained clinical outcomes up to 5-year follow-up, with a low rate (1.4%) of significant prosthetic valve degeneration. The procedure appears to be an adequate and lasting resolution of aortic stenosis in selected high-risk patients.
Background There is limited information on the long-term outcomes and prognostic clinical predictors after edge-to-edge transcatheter mitral valve repair with the MitraClip system. Methods ...Consecutive patients with mitral regurgitation (MR) undergoing MitraClip therapy between October 2008 and November 2013 in 4 Italian centers were analyzed. The primary end point of interest was all-cause death. The secondary end point was the composite of all-cause death or rehospitalization for heart failure. Results A total of 304 patients were included, of which 79% had functional MR and 17% were in New York Heart Association functional class IV. Acute procedural success was obtained in 92% of cases, with no intraprocedural death. The cumulative incidences of all-cause death were 3.4%, 10.8%, and 18.6% at 30 days, 1 year, and 2 years, respectively. The corresponding incidences of the secondary end point were 4.4%, 22.0%, and 39.7%, respectively. In the Cox multivariate model, New York Heart Association functional class IV at baseline and ischemic MR etiology were found to significantly and independently predict both the primary and the secondary end point. A baseline, left ventricular end-systolic volume >110 mL was found to be an independent predictor of the secondary endpoint. Acute procedural success was independently associated with a lower risk of all-cause death and the combination of all-cause death or rehospitalization for heart failure at long-term follow-up. Conclusions In a cohort of patients undergoing MitraClip therapy, those presenting at baseline with ischemic functional etiology, severely dilated ventricles, or advanced heart failure and those undergoing unsuccessful procedures carried the worst prognosis.
Percutaneous mitral valve repair (PMVR) using the MitraClip System is feasible and entails clinical improvement even in patients with high surgical risk and severe functional mitral regurgitation ...(MR). The aim of this study was to assess survival rates and clinical outcome of patients with severe, functional MR treated with optimal medical therapy (OMT) compared with those who received MitraClip device. Sixty patients treated with OMT were compared with a propensity-matched cohort of 60 patients who underwent PMVR. Baseline demographics and echocardiographic variables were similar between the 2 groups. The mean age of patients was 75 years, and 67% were men. The median logistic EuroSCORE and EuroSCORE II were 17% and 6%, respectively, because of the presence of several co-morbidities. The mechanism of MR was functional in all cases with an ischemic etiology in 52% of patients. Median left ventricle ejection fraction was 34%. All the patients were symptomatic for dyspnea with 63% and 12% in the New York Heart Association class III and IV, respectively. In PMVR group, the procedure was associated with safety and very low incidence of procedural complications with no occurrence of procedural and inhospital mortality. After a median follow-up of 515 days (248 to 828 days), patients treated with PMVR demonstrated overall survival, survival freedom from cardiac death and survival free of readmission due to cardiac disease curves higher than patients treated conservatively (log-rank test p = 0.007, p = 0.002, and p = 0.04, respectively). In conclusion, PMVR offers a valid option for selected patients with high surgical risk and severe, functional MR and entails better survival outcomes compared with OMT.
Background Conduction abnormalities are frequent after transcatheter aortic valve implantation with the CoreValve (Medtronic, Minneapolis, MN) and are often treated with liberal permanent pacemaker ...(PPM) implantation. Our aim was to assess the 1-year outcome of a conservative approach to pacing and to identify its predictors. Methods We analyzed 275 consecutive patients without a PPM before transcatheter aortic valve implantation who underwent successful CoreValve implantation at our 3 centers, sharing a conservative approach to pacing. Results Of the 47 patients (17.1%) who developed postprocedural complete atrioventricular block, 14 recovered spontaneous atrioventricular conduction <72 hours and did not receive a PPM. Sixty-six patients (24.0%) received a PPM before discharge, and 74 more patients (26.9%) developed a new left bundle-branch block (LBBB). Independent predictors of PPM implantation were as follows: lower CoreValve implantation below the aortic annulus (odds ratio OR 1.16/mm, 95% CI 1.03-1.30, P = .01), right bundle-branch block (OR 3.72, 95% CI 1.5-9.2, P = .004), left anterior hemiblock (OR 2.34, 95% CI 1.1-5.1, P = .03), and longer PR interval (OR 1.02/ms, 95% CI 1.00-1.04, P = .03). One-year survival was similar between patients who received a PPM and patients who did not receive a PPM ( P = .90), with no case of sudden death in the latter group, and between patients with a new LBBB not receiving a PPM and patients without postprocedural LBBB ( P = .37). Conclusion A high CoreValve implantation level and avoidance of prophylactic pacing in patients with new LBBB without persistent bradyarrhythmias allowed for a relatively low rate of PPM implantation. This conservative approach spared unwarranted pacing and did not affect 1-year survival.
Although transcatheter aortic valve implantation (TAVI) for severe aortic stenosis is becoming an established technique, the effect of gender-related differences is poorly described. We performed a ...gender-based comparison of high-risk patients undergoing TAVI with the self-expandable CoreValve Revalving System for severe aortic stenosis to evaluate early and mid-term clinical outcomes. From the Italian prospective CoreValve registry, 659 consecutive patients (55.8% women) who underwent TAVI were included in the present study. We analyzed the gender-based differences in terms of clinical, angiographic, and procedural features and the differences in the rate of early and mid-term major adverse cardiac and cerebrovascular events. The men were younger, presented more often with severe left ventricular dysfunction, and had a greater rate of previous myocardial infarction, coronary revascularization, peripheral artery disease, renal failure, and heart conduction disorders than the women. The logistic European System for Cardiac Operative Risk Evaluation score did not differ between the 2 groups. The overall unadjusted and adjusted analyses failed to show significant differences between genders in terms of major adverse cardiac and cerebrovascular events at a median follow-up of 13 months (range 8 to 18). At late follow-up (landmark analysis >12 months), a survival benefit was observed in women (hazard ratio 0.27, 95% confidence interval 0.09 to 0.84, p = 0.02). In conclusion, in this multicenter registry, the gender-based comparison of TAVI patients showed that men, despite the younger age, had more extensive atherosclerotic burden compared to women. Overall, the early and mid-term outcomes were similar between genders, although women might have a survival benefit with longer follow-up.
The aim of this study was to explore the adaptability of 3 contemporary surgical scores (Logistic EuroSCORE LES, EuroSCORE II ESII, and Society of Thoracic Surgeons Predicted Risk of Mortality ...STS-PROM) for prediction of mortality after percutaneous mitral valve repair with the MitraClip system. A total of 304 patients from the multicenter Getting Reduction of mitrAl inSufficiency by Percutaneous clip implantation in ITaly registry (GRASP-IT) were stratified based on LES, ESII, and STS-PROM tertiles and analyzed by different measurements of discrimination, calibration, and global accuracy with focus on 30-day and 1-, 2-, and 3-year mortality. A statistically significant gradient in the distribution of mortality was observed at all time points with ESII, at 2 years with LES, and at 2 and 3 years with STS-PROM. ESII had the best discrimination at 30 days (C-statistic 0.80), which remained acceptable at later follow-up, being significantly superior to that of LES at each time point (p = 0.003 at 30 days, p = 0.005 at 1 year, p = 0.011 at 2 years, and p = 0.029 at 3 years). Compared with STS-PROM, ESII showed better discrimination at 30 days (C-statistic 0.80 vs 0.62, p = 0.023). All scores overpredicted the risk of mortality at 30 days and were miscalibrated at 2 and 3 years. At 1 year, there was a good agreement between the observed and predicted probabilities for ESII and STS-PROM, whereas LES remained overpredictive. ESII showed the best global accuracy at 30 days and 1 year, whereas no notable differences were noted versus LES and STS-PROM at 2 and 3 years. In conclusion, lacking specific tools for risk stratification of patients undergoing MitraClip implantation, ESII holds favorable prognostic characteristics, which makes it a valid surrogate.
The Italian Elderly ACS study was the first randomized controlled trial comparing an early aggressive with an initially conservative strategy in patients with non–ST-segment elevation acute coronary ...syndromes aged ≥75 years, with the results showing no significant benefit of early aggressive therapy. The aim of this study was to evaluate the outcomes of trial patients, according to the treatment actually received during hospitalization. The trial enrolled 313 patients. The primary end point was the composite of death, myocardial infarction (MI), disabling stroke, and repeat hospital stay for cardiovascular causes or bleeding within 1 year. All patients in whom coronary angiography was performed during initial hospitalization were defined as having undergone invasive treatment (182 patients), whereas all patients who did not undergo coronary angiography were classified as medically managed (conservative treatment CT group, 131 patients). The primary end point occurred in 53 patients (40.5%) in the CT group and 45 patients (24.7%) in the invasive treatment group (hazard ratio 0.56, 95% confidence interval 0.37 to 0.83, p = 0.003). The invasive treatment group showed significantly lower rates of MI (6% vs 13% in the CT group; hazard ratio 0.43, 95% confidence interval 0.20 to 0.92, p = 0.034) and the aggregate of death and MI (14.3% vs 27.5% CT group; hazard ratio 0.48, 95% confidence interval 0.29 to 0.81, p = 0.004). In conclusion, elderly patients with non–ST-segment elevation acute coronary syndromes treated invasively experienced significantly better survival free from the composite of all-cause mortality, nonfatal MI, disabling stroke, and repeat hospitalization for cardiovascular causes or bleeding.
Abstract Background Elderly patients display higher on clopidogrel platelet reactivity as compared to younger patients. Treatment with prasugrel 5 mg has been shown to provide more predictable and ...homogenous antiplatelet effect, as compared to clopidogrel, suggesting the possibility of reducing ischemic events after an acute coronary syndrome (ACS) without increasing bleeding. Study design The Elderly-ACS 2 study is a multicenter, randomized, parallel-group, open-label trial designed to demonstrate the superiority of a strategy of dual antiplatelet treatment using a reduced 5 mg daily dose of prasugrel over a standard strategy with a daily clopidogrel dose of 75 mg in patients >74 years of age with ACS (either ST- or non ST-elevation myocardial infarction) undergoing early percutaneous revascularization. The primary endpoint is the composite of all-cause mortality, myocardial re-infarction, disabling stroke and re-hospitalization for cardiovascular causes or bleeding within one year. Taking advantage of the planned size of 2000 patients, the secondary objective is to assess the prognostic impact of selected pre-randomization variables (age, sex, diabetic status, serum creatinine level, ECG changes, abnormal troponin levels, basal and residual SYNergy between percutaneous coronary intervention with TAXus and cardiac surgery SYNTAX score). Conclusion The Elderly-ACS 2 study is a multicenter, randomized trial comparing a strategy of dual antiplatelet therapy with a reduced dose of prasugrel with a standard dose of clopidogrel in elderly patients with ACS undergoing percutaneous revascularization. (The Elderly ACS 2 trial: NCT01777503 )
Abstract Objectives The aim of this study was to assess the incidence and clinical impact of balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR) with the CoreValve ...prosthesis (Medtronic Inc., Minneapolis, Minnesota). Background BPD is a widely adopted strategy to reduce the degree of paraprosthetic regurgitation in case of transcatheter heart valve underexpansion. However, controversies still remain regarding its real effectiveness and safety. Methods The ClinicalService (a nation-based data repository and medical care project) dataset was analyzed. All patients were dichotomized according to the need for BPD during the index procedure. Results Among 1,376 patients, BPD of the transcatheter heart valve was performed in 272 (19.8%). In 37% of cases, it was unsuccessful at reducing the paravalvular regurgitation to mild or less. No case of valve embolization, new intravalvular regurgitation, coronary occlusion, and aortic root injury occurred during BPD. There were no statistically significant differences between the 2 groups in the incidence of in-hospital all-cause and cardiovascular mortality, neurological events, myocardial infarction, bleeding, conversion to open-chest surgery, and the need for a permanent pacemaker. The need for BPD did not emerge as an independent risk factor for all-cause (adjusted hazard ratio HR: 1.33, 95% confidence interval CI: 0.81 to 2.19, p = 0.264) and cardiovascular (adjusted HR: 1.48, 95% CI: 0.74 to 2.97, p = 0.265) mortality at 1 year after the procedure. In addition, BPD did not predispose to higher odds of neurological events during 12 months after TAVR (HR: 0.92, 95% CI: 0.45 to 1.88, p = 0.815). Conclusions This large study showed that BPD after TAVR was safe and not associated with increased rates of cerebrovascular events, mortality, myocardial infarction, and aortic root injury.