X-ray ptychographic microscopy combines the advantages of raster scanning X-ray microscopy with the more recently developed techniques of coherent diffraction imaging. It is limited neither by the ...fabricational challenges associated with X-ray optics nor by the requirements of isolated specimen preparation, and offers in principle wavelength-limited resolution, as well as stable access and solution to the phase problem. In this Review, we discuss the basic principles of X-ray ptychography and summarize the main milestones in the evolution of X-ray ptychographic microscopy and tomography over the past ten years, since its first demonstration with X-rays. We also highlight the potential for applications in the life and materials sciences, and discuss the latest advanced concepts and probable future developments.
X-ray tomography is an invaluable tool in biomedical imaging. It can deliver the three-dimensional internal structure of entire organisms as well as that of single cells, and even gives access to ...quantitative information, crucially important both for medical applications and for basic research. Most frequently such information is based on X-ray attenuation. Phase contrast is sometimes used for improved visibility but remains significantly harder to quantify. Here we describe an X-ray computed tomography technique that generates quantitative high-contrast three-dimensional electron density maps from phase contrast information without reverting to assumptions of a weak phase object or negligible absorption. This method uses a ptychographic coherent imaging approach to record tomographic data sets, exploiting both the high penetration power of hard X-rays and the high sensitivity of lensless imaging. As an example, we present images of a bone sample in which structures on the 100 nm length scale such as the osteocyte lacunae and the interconnective canalicular network are clearly resolved. The recovered electron density map provides a contrast high enough to estimate nanoscale bone density variations of less than one per cent. We expect this high-resolution tomography technique to provide invaluable information for both the life and materials sciences.
Celotno besedilo
Dostopno za:
DOBA, IJS, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
4.
High-Resolution Scanning X-ray Diffraction Microscopy Thibault, Pierre; Dierolf, Martin; Menzel, Andreas ...
Science (American Association for the Advancement of Science),
07/2008, Letnik:
321, Številka:
5887
Journal Article
Recenzirano
Coherent diffractive imaging (CDI) and scanning transmission x-ray microscopy (STXM) are two popular microscopy techniques that have evolved quite independently. CDI promises to reach resolutions ...below 10 nanometers, but the reconstruction procedures put stringent requirements on data quality and sample preparation. In contrast, STXM features straightforward data analysis, but its resolution is limited by the spot size on the specimen. We demonstrate a ptychographic imaging method that bridges the gap between CDI and STXM by measuring complete diffraction patterns at each point of a STXM scan. The high penetration power of x-rays in combination with the high spatial resolution will allow investigation of a wide range of complex mesoscopic life and material science specimens, such as embedded semiconductor devices or cellular networks.
Dark-field computed tomography reaches the human scale Viermetz, Manuel; Gustschin, Nikolai; Schmid, Clemens ...
Proceedings of the National Academy of Sciences - PNAS,
02/2022, Letnik:
119, Številka:
8
Journal Article
Recenzirano
Odprti dostop
X-ray computed tomography (CT) is one of the most commonly used three-dimensional medical imaging modalities today. It has been refined over several decades, with the most recent innovations ...including dual-energy and spectral photon-counting technologies. Nevertheless, it has been discovered that wave-optical contrast mechanisms-beyond the presently used X-ray attenuation-offer the potential of complementary information, particularly on otherwise unresolved tissue microstructure. One such approach is dark-field imaging, which has recently been introduced and already demonstrated significantly improved radiological benefit in small-animal models, especially for lung diseases. Until now, however, dark-field CT could not yet be translated to the human scale and has been restricted to benchtop and small-animal systems, with scan durations of several minutes or more. This is mainly because the adaption and upscaling to the mechanical complexity, speed, and size of a human CT scanner so far remained an unsolved challenge. Here, we now report the successful integration of a Talbot-Lau interferometer into a clinical CT gantry and present dark-field CT results of a human-sized anthropomorphic body phantom, reconstructed from a single rotation scan performed in 1 s. Moreover, we present our key hardware and software solutions to the previously unsolved roadblocks, which so far have kept dark-field CT from being translated from the optical bench into a rapidly rotating CT gantry, with all its associated challenges like vibrations, continuous rotation, and large field of view. This development enables clinical dark-field CT studies with human patients in the near future.
When used in combination with raster scanning, small-angle X-ray scattering (SAXS) has proven to be a valuable imaging technique of the nanoscale, for example of bone, teeth and brain matter. ...Although two-dimensional projection imaging has been used to characterize various materials successfully, its three-dimensional extension, SAXS computed tomography, poses substantial challenges, which have yet to be overcome. Previous work using SAXS computed tomography was unable to preserve oriented SAXS signals during reconstruction. Here we present a solution to this problem and obtain a complete SAXS computed tomography, which preserves oriented scattering information. By introducing virtual tomography axes, we take advantage of the two-dimensional SAXS information recorded on an area detector and use it to reconstruct the full three-dimensional scattering distribution in reciprocal space for each voxel of the three-dimensional object in real space. The presented method could be of interest for a combined six-dimensional real and reciprocal space characterization of mesoscopic materials with hierarchically structured features with length scales ranging from a few nanometres to a few millimetres--for example, biomaterials such as bone or teeth, or functional materials such as fuel-cell or battery components.
Celotno besedilo
Dostopno za:
DOBA, IJS, IZUM, KILJ, KISLJ, NUK, PILJ, PNG, SAZU, SBMB, SIK, UILJ, UKNU, UL, UM, UPUK
8.
Der Edelstein Boner, Ulrich; Pfeiffer, Franz
2019, 2019-01-14
eBook
Objectives
Evaluation of imaging performance across dual-energy CT (DECT) platforms, including dual-layer CT (DLCT), rapid-kVp-switching CT (KVSCT) and dual-source CT (DSCT).
Methods
A ...semi-anthropomorphic abdomen phantom was imaged on these DECT systems. Scans were repeated three times for CTDIvol levels of 10 mGy, 20 mGy, 30 mGy and different fat-simulating extension rings. Over the available range of virtual-monoenergetic images (VMI), noise as well as quantitative accuracy of hounsfield units (HU) and iodine concentrations were evaluated.
Results
For all VMI levels, HU values could be determined with high accuracy compared to theoretical values. For KVSCT and DSCT, a noise increase was observed towards lower VMI levels. A patient-size dependent increase in the uncertainty of quantitative iodine concentrations is observed for all platforms. For a medium patient size the iodine concentration root-mean-square deviation at 20 mGy is 0.17 mg/ml (DLCT), 0.30 mg/ml (KVSCT) and 0.77mg/ml (DSCT).
Conclusion
Noticeable performance differences are observed between investigated DECT systems. Iodine concentrations and VMI HUs are accurately determined across all DECT systems. KVSCT and DLCT deliver slightly more accurate iodine concentration values than DSCT for investigated scenarios. In DLCT, low-noise and high-image contrast at low VMI levels may help to increase diagnostic information in abdominal CT.
Key Points
• Current dual-energy CT platforms provide accurate, reliable quantitative information.
• Dual-energy CT cross-platform evaluation revealed noticeable performance differences between different systems.
• Dual-layer CT offers constant noise levels over the complete energy range.
To evaluate virtual-non-contrast (VNC) images obtained from clinical triphasic scans with a dual-layer spectral computed tomography system regarding accuracy of iodine subtraction.
From September to ...December 2016, 62 consecutive patients who underwent a clinical routine triphasic CT examination were included into this retrospective study. VNC images based on the arterial and portal venous phase were generated. For every patient and every contrast phase, a region-of-interest (ROI) was defined in aorta, liver, renal cortex, spongious bone, fat, muscle and fluid (i.e. gallbladder, urinary bladder), resulting in 2170 ROIs. VNC images were compared to true-non-contrast (TNC) images regarding difference in attenuation. Consistency between VNC images obtained from the arterial and portal venous phase as well as the influence of the initial attenuation on respective VNC images were evaluated.
Comparison of HU in VNC and TNC images showed a high accuracy of iodine elimination. Mean difference between TNC and VNC images was only 0.5 ± 8.5 HU and >90% of all comparisons showed a difference of less than 15 HU. For all tissues but spongious bone, mean absolute difference between TNC and VNC images was below 10 HU. VNC images derived from the arterial and the portal venous phase showed excellent correlation. The quality of iodine removal in VNC images was not influenced by the original contrast enhancement. However, VNC images cannot be used for evaluation of iodine removal in bone as bone and iodine can hardly be differentiated via spectral CT.
VNC imaging in DL-CT is a promising tool for daily clinical routine. As non-enhanced CT images are essential in multiple clinical situations, the permanent availability of VNC images with dual-layer spectral CT will result in a substantial reduction of radiation exposure and an increased diagnostic value of monophasic contrast-enhanced CT scans.