The aim of the SYRMA-CT collaboration is to set-up the first clinical trial of phase-contrast breast CT with synchrotron radiation (SR). In order to combine high image quality and low delivered dose ...a number of innovative elements are merged: a CdTe single photon counting detector, state-of-the-art CT reconstruction and phase retrieval algorithms. To facilitate an accurate exam optimization, a Monte Carlo model was developed for dose calculation using GEANT4. In this study, high isotropic spatial resolution (120 μm)3 CT scans of objects with dimensions and attenuation similar to a human breast were acquired, delivering mean glandular doses in the range of those delivered in clinical breast CT (5-25 mGy). Due to the spatial coherence of the SR beam and the long distance between sample and detector, the images contain, not only absorption, but also phase information from the samples. The application of a phase-retrieval procedure increases the contrast-to-noise ratio of the tomographic images, while the contrast remains almost constant. After applying the simultaneous algebraic reconstruction technique to low-dose phase-retrieved data sets (about 5 mGy) with a reduced number of projections, the spatial resolution was found to be equal to filtered back projection utilizing a four fold higher dose, while the contrast-to-noise ratio was reduced by 30%. These first results indicate the feasibility of clinical breast CT with SR.
PIXIE III is the third generation of very large area (32 x 25 mm super(2)) pixel ASICs developed by Pixirad Imaging Counters s.r.l. to be used in combination with suitable X-ray sensor materials ...(Silicon, CdTe, GaAs) in hybrid assemblies using flip-chip bonding. A Pixirad unit module based on PIXIE III shows several advances compared to what has been available up to now. It has a very broad energy range (from 2 to 100 keV before full pulse saturation), high speed (100 ns peaking time), high frame rate (larger than 500 fps), dead-time-free operation, good energy resolution (around 2 keV at 20 keV), high photo-peak fraction and sharp spectral separation between the color images. In this paper the results obtained with PIXIE III both in a test bench set-up as well in X-ray imaging applications are discussed.
Assembly and test of the gas pixel detector for X-ray polarimetry Li, H.; Feng, H.; Muleri, F. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2015, Letnik:
804
Journal Article
Recenzirano
Odprti dostop
The gas pixel detector (GPD) dedicated for photoelectric X-ray polarimetry is selected as the focal plane detector for the ESA medium-class mission concept X-ray Imaging and Polarimetry Explorer ...(XIPE). Here we show the design, assembly, and preliminary test results of a small GPD for the purpose of gas mixture optimization needed for the phase A study of XIPE. The detector is assembled in house at Tsinghua University following a design by the INFN-Pisa group. The improved detector design results in a good uniformity for the electric field. Filled with pure dimethyl ether (DME) at 0.8atm, the measured energy resolution is 18% at 6keV and inversely scales with the square root of the X-ray energy. The measured modulation factor is well consistent with that from simulation, up to ~0.6 above 6keV. The residual modulation is found to be 0.30±0.15% at 6keV for the whole sensitive area, which can be translated into a systematic error of less than 1% for polarization measurement at a confidence level of 99%. The position resolution of the detector is about 80μm in FWHM, consistent with previous studies and sufficient for XIPE requirements.
The aim of this work is the characterization of the Pixirad-1 detector system with monochromatic synchrotron radiation at different energies. The linearity of the system has been investigated varying ...the impinging photon flux up to paralyzation. The ratio between detector counts and number of impinging photons, as a function of energy and discriminator thresholds, has been measured. The pixel noise has been evaluated and the result compared with the theoretical Poisson model. Eventually, the spatial resolution has been evaluated by measuring the line-spread function at different energies and discriminator thresholds.
The Gas Pixel Detector belongs to the very limited class of gas detectors optimized for the measurement of X-ray polarization in the emission of astrophysical sources. The choice of the mixture in ...which X-ray photons are absorbed and photoelectrons propagate, deeply affects both the energy range of the instrument and its performance in terms of gain, track dimension and ultimately, polarimetric sensitivity. Here we present the characterization of the Gas Pixel Detector with a 1
cm thick cell filled with dimethyl ether (DME) at 0.79
atm, selected among other mixtures for the very low diffusion coefficient. Almost completely polarized and monochromatic photons were produced at the calibration facility built at INAF/IASF-Rome exploiting Bragg diffraction at nearly 45°. For the first time ever, we measured the modulation factor and the spectral capabilities of the instrument at energies as low as 2.0
keV, but also at 2.6, 3.7, 4.0, 5.2 and 7.8
keV. These measurements cover almost completely the energy range of the instrument and allows to compare the sensitivity achieved with that of the standard mixture, composed of helium and DME.
X-ray diffraction (XRD) is a powerful tool for material identification. In order to interpret XRD data, knowledge is required of the scattering angles and energies of X-rays which interact with the ...sample. By using a pixellated, energy-resolving detector, this knowledge can be gained when using a spectrum of unfiltered X-rays, and without the need to collimate the scattered radiation. Here we present results of XRD measurements taken with the Pixirad detector and a laboratory-based X-ray source. The cadmium telluride sensor allows energy windows to be selected, and the 62 mum pixel pitch enables accurate spatial information to be preserved for XRD measurements, in addition to the ability to take high resolution radiographic images. Diffraction data are presented for a variety of samples to demonstrate the capability of the technique for materials discrimination in laboratory, security and pharmaceutical environments. Distinct diffraction patterns were obtained, from which details on the molecular structures of the items under study were determined.
Low energy polarization sensitivity of the Gas Pixel Detector Muleri, F.; Soffitta, P.; Baldini, L. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
2008, 2008-1-00, Letnik:
584, Številka:
1
Journal Article
Recenzirano
Odprti dostop
An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been proposed to be included in many upcoming space missions to fill the gap of about 30 years from the first (and to date only) ...positive measurement of polarized X-ray emission from an astrophysical source. The estimated sensitivity of the current prototype peaks at an energy of about 3
keV, but the lack of readily available polarized sources in this energy range has prevented the measurement of detector polarimetric performances.
In this paper we present the measurement of the Gas Pixel Detector polarimetric sensitivity at energies of a few keV and the new, light, compact and transportable polarized source that was devised and built to this aim. Polarized photons are produced, from unpolarized radiation generated with an X-ray tube, by means of Bragg diffraction at nearly
45
∘
. The diffraction angle is constrained with two orthogonal capillary plates, which allow good collimation with limited size thanks to the
10
μ
m
diameter holes. Polarized photons at energy as low as a few keV can be produced with a proper choice of diffracting crystal, while the maximum energy is limited by the X-ray tube voltage, since all the orders defined by the crystal lattice spacing are diffracted. The best trade-off between reasonable fluxes and high degree of polarization can be achieved selecting the degree of collimation provided by capillary plates.
The employment of mosaic graphite and flat aluminum crystals allow the production of nearly completely polarized photons at 2.6, 3.7, and 5.2
keV from the diffraction of unpolarized continuum or line emission. The measured modulation factor of the Gas Pixel Detector at these energies is in good agreement with the estimates derived from a Monte Carlo software, which was up to now employed for driving the development of the instrument and for estimating its low energy sensitivity. In this paper we present the excellent polarimetric performance of the Gas Pixel Detector at energies where the peak sensitivity is expected. These measurements not only support our previous claims of high sensitivity but confirm the feasibility of astrophysical X-ray photoelectric polarimetry.
Due to be launched in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2–8 keV band, complemented with ...imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collecting anode.
In this paper we shall review the design, manufacturing, and test of the IXPE focal-plane detectors, with particular emphasis on the connection between the science drivers, the performance metrics and the operational aspects. We shall present a thorough characterization of the GPDs in terms of effective noise, trigger efficiency, dead time, uniformity of response, and spectral and polarimetric performance. In addition, we shall discuss in detail a number of instrumental effects that are relevant for high-level science analysis—particularly as far as the response to unpolarized radiation and the stability in time are concerned.
While the successful launch and operation in space of the Gas Pixel Detectors onboard the PolarLight cubesat and the Imaging X-ray Polarimetry Explorer demonstrate the viability and the technical ...soundness of this class of detectors for astronomical X-ray polarimetry, it is clear that the current state of the art is not ready to meet the challenges of the next generation of experiments, such as the enhanced X-ray Timing and Polarimetry mission, designed to allow for a significantly larger data throughput.
In this paper we describe the design and test of a new custom, self-triggering readout ASIC, dubbed XPOL-III, specifically conceived to address and overcome these limitations. While building upon the overall architecture of the previous generations, the new chip improves over its predecessors in several, different key areas: the sensitivity of the trigger electronics, the flexibility in the definition of the readout window, as well as the maximum speed for the serial event readout. These design improvements, when combined, allow for almost an order of magnitude smaller dead time per event with no measurable degradation of the polarimetric, spectral, imaging or timing capability of the detector, providing a good match for the next generation of X-ray missions.