Polarizers play a key role in generating polarized light for display, imaging, and data communication, but adoption often suffers from high optical loss. Recently, due to superior optoelectronic ...properties, halide perovskites have been widely developed for lighting applications; however, highly polarized emission (polarization degree >0.8) has not yet been realized with perovskites. Herein, by incorporating inkjet printing and an anodic aluminum oxide (AAO) confinement strategy, highly ordered perovskite nanowire (NW) arrays are demonstrated for anisotropic optical applications. The optical device based on perovskite NW arrays reveals a high photoluminescence external quantum efficiency of 21.6% and emits highly polarized light with polarization degree up to 0.84. The highly polarized emission from perovskite NW arrays has potential to considerably reduce the optical loss of polarizers, which may attract great interest in developing polarized light sources for next‐generation optoelectronic applications.
By incorporating inkjet printing with anodic aluminum oxide nanoporous confinement, highly ordered perovskite nanowire arrays are fabricated, which can emit extremely polarized light with a polarization degree up to 0.84.
Magnifying narrow-band imaging (M-NBI) is important in the diagnosis of early gastric cancers (EGCs) but requires expertise to master. We developed a computer-aided diagnosis (CADx) system to assist ...endoscopists in identifying and delineating EGCs.
We retrospectively collected and randomly selected 66 EGC M-NBI images and 60 non-cancer M-NBI images into a training set and 61 EGC M-NBI images and 20 non-cancer M-NBI images into a test set. After preprocessing and partition, we determined 8 gray-level co-occurrence matrix (GLCM) features for each partitioned 40 × 40 pixel block and calculated a coefficient of variation of 8 GLCM feature vectors. We then trained a support vector machine (SVMLv1) based on variation vectors from the training set and examined in the test set. Furthermore, we collected 2 determined P and Q GLCM feature vectors from cancerous image blocks containing irregular microvessels from the training set, and we trained another SVM (SVMLv2) to delineate cancerous blocks, which were compared with expert-delineated areas for area concordance.
The diagnostic performance revealed accuracy of 96.3%, precision (positive predictive value PPV) of 98.3%, recall (sensitivity) of 96.7%, and specificity of 95%, at a rate of 0.41 ± 0.01 seconds per image. The performance of area concordance, on a block basis, demonstrated accuracy of 73.8% ± 10.9%, precision (PPV) of 75.3% ± 20.9%, recall (sensitivity) of 65.5% ± 19.9%, and specificity of 80.8% ± 17.1%, at a rate of 0.49 ± 0.04 seconds per image.
This pilot study demonstrates that our CADx system has great potential in real-time diagnosis and delineation of EGCs in M-NBI images.
We investigate the optical properties of gold nanoring (NR) dimers in both simulation and experiment. The resonance peak wavelength of gold NR dimers is strongly dependent on the polarization ...direction and gap distance. As the gold NR particles approach each other, exponential red shift and slight blue shift of coupled bonding (CB) mode in gold NR dimers for longitudinal and transverse polarizations are obtained. In finite element method analysis, a very strong surface plasmon coupling in the gap region of gold NR dimers is observed, whose field intensity at the gap distance of 10 nm is enhanced 23% compared to that for gold nanodisk (ND) dimers with the same diameter. In addition, plasmonic dimer system exhibits a great improvement in the sensing performance. Near-field coupling in gold NR dimers causes exponential increase in sensitivity to refractive index of surrounding medium with decreasing the gap distance. Compared with coupled dipole mode in gold ND dimers, CB mode in gold NR dimers shows higher index sensitivity. This better index sensing performance is resulted form the additional electric field in inside region of NR and the larger field enhancement in the gap region owing to the stronger coupling of collective dipole plasmon resonances for CB mode. These results pave the way to design plasmonic nanostructures for practical applications that require coupled metallic nanoparticles with enhanced electric fields.
Plasmonic waveguides allow focusing, guiding, and manipulating light at the nanoscale and promise the miniaturization of functional optical nanocircuits. Dielectric-loaded plasmonic (DLP) waveguides ...and logic gates have drawn attention because of their relatively low loss, easy fabrication, and good compatibility with gain and active tunable materials. However, the rather low on/off ratio of DLP logic gates remains the main challenge. Here, we introduce an amplitude modulator and theoretically demonstrate an enhanced on/off ratio of a DLP logic gate for XNOR operation. Multimode interference (MMI) in DLP waveguide is precisely calculated for the design of the logic gate. Multiplexing and power splitting at arbitrary multimode numbers have been theoretically analyzed with respect to the size of the amplitude modulator. An enhanced on/off ratio of 11.26 dB has been achieved. The proposed amplitude modulator can also be used to optimize the performance of other logic gates or MMI-based plasmonic functional devices.
A subset of IgA nephropathy (IgAN) patients exhibiting minimal change disease (MCD) like features present with nephrotic-range proteinuria and warrants immunosuppressive therapy (IST). However, the ...diagnosis of MCD-like IgAN varied by reports. We aimed to identify the key pathological features of MCD-like IgAN.
In this cohort, 228 patients had biopsy-proven IgAN from 2009 to 2021, of which 44 without segmental sclerosis were enrolled. Patients were classified into segmental (< 50% glomerular capillary loop involvement) or global (> 50%) foot process effacement (FPE) groups. We further stratified them according to the usage of immunosuppressant therapy after biopsy. Clinical manifestations, treatment response, and renal outcome were compared.
26 cases (59.1%) were classified as segmental FPE group and 18 cases (40.9%) as global FPE group. The global FPE group had more severe proteinuria (11.48 2.60, 15.29 vs. 0.97 0.14, 1.67 g/g, p = 0.001) and had a higher proportion of complete remission (81.8% vs. 20%, p = 0.018). In the global FPE group, patients without IST experienced more rapid downward eGFR change than the IST-treated population (-0.38 -1.24, 0.06 vs. 1.26 -0.17, 3.20mL/min/1.73 m2/month, p = 0.004).
The absence of segmental sclerosis and the presence of global FPE are valuable pathological features that assist in identifying MCD-like IgAN.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
High-quality epitaxial layers are directly related to internal quantum efficiency. The methods used to design such epitaxial layers are reviewed in this article. The ultraviolet C (UVC) ...light-emitting diode (LED) epitaxial layer structure exhibits electron leakage; therefore, many research groups have proposed the design of blocking layers and carrier transportation to generate high electron–hole recombination rates. This also aids in increasing the internal quantum efficiency. The cap layer, p-GaN, exhibits high absorption in deep UV radiation; thus, a small thickness is usually chosen. Flip chip design is more popular for such devices in the UV band, and the main factors for consideration are light extraction and heat transportation. However, the choice of encapsulation materials is important, because unsuitable encapsulation materials will be degraded by ultraviolet light irradiation. A suitable package design can account for light extraction and heat transportation. Finally, an atomic layer deposition Al2O3 film has been proposed as a mesa passivation layer. It can provide a low reverse current leakage. Moreover, it can help increase the quantum efficiency, enhance the moisture resistance, and improve reliability. UVC LED applications can be used in sterilization, water purification, air purification, and medical and military fields.
ObjectivesThe ProGlide® vascular closure device (Abbott Vascular, Redwood City, CA, USA) is approved for the closure of arterial punctures (typically 5–21 Fr sheath; maximum outer diameter, 26 Fr). ...However, a failure rate of about 2–8% is reported. This study was conducted to analyse factors predisposing to failure when the devices were used for the closure of large hole (16–26 Fr) arteriotomies, and to determine the predictive cut off values of predisposing factors. MethodsIn this retrospective study, the ProGlide® device was used to achieve vascular access site closure in 458 patients undergoing repair of abdominal aortic aneurysm, thoracic aortic aneurysm, type B aortic dissection, or transcatheter aortic valve implantation. The primary endpoint was device failure, defined as inability to achieve common femoral artery (CFA) closure; successful repair, development of acute lower limb ischaemia and haemodynamic compromise; or delayed pseudoaneurysm formation during the follow up period, requiring open repair. ResultsOverall, ProGlide® failure occurred in 7.6% of cases. Factors that predisposed to failure included a history of peripheral arterial disease (PAD) ( p < .001), the presence of CFA calcification ( p < .001), the depth of the skin puncture site ≥ 33 mm ( p < .001), body mass index (BMI) of ≥28.7 kg/m 2 ( p < .001), and use of sheath size ≥ 19 Fr ( p < .001). ConclusionFactors such as BMI, history of PAD, the presence of CFA calcification, the depth of the skin puncture site, and sheath size are significantly associated with ProGlide® failure. Hence, careful patient and device selection and operating procedure are paramount to achieve successful outcomes.
In recent years, the process requirements of nano-devices have led to the gradual reduction in the scale of semiconductor devices, and the consequent non-negligible sidewall defects caused by ...etching. Since plasma-enhanced chemical vapor deposition can no longer provide sufficient step coverage, the characteristics of atomic layer deposition ALD technology are used to solve this problem. ALD utilizes self-limiting interactions between the precursor gas and the substrate surface. When the reactive gas forms a single layer of chemical adsorbed on the substrate surface, no reaction occurs between them and the growth thickness can be controlled. At the Å level, it can provide good step coverage. In this study, recent research on the ALD passivation on micro-light-emitting diodes and vertical cavity surface emitting lasers was reviewed and compared. Several passivation methods were demonstrated to lead to enhanced light efficiency, reduced leakage, and improved reliability.
Pulmonary artery hypertension (PAH) pathology involves extracellular matrix (ECM) remodeling in cardiac tissues, thus promoting cardiac fibrosis progression. miR-29a-3p reportedly inhibits lung ...progression and liver fibrosis by regulating ECM protein expression; however, its role in PAH-induced fibrosis remains unclear. In this study, we aimed to investigate the role of miR-29a-3p in cardiac fibrosis progression in PAH and its influence on ECM protein thrombospondin-2 (THBS2) expression. The diagnostic and prognostic values of miR-29a-3p and THBS2 in PAH were evaluated. The expressions and effects of miR-29a-3p and THBS2 were assessed in cell culture, monocrotaline-induced PAH mouse model, and patients with PAH. The levels of circulating miR-29a-3p and THBS2 in patients and mice with PAH decreased and increased, respectively. miR-29a-3p directly targets THBS2 and regulates THBS2 expression via a direct anti-fibrotic effect on PAH-induced cardiac fibrosis. The circulating levels of miR-29a-3p and THBS2 were correlated with PAH diagnostic parameters, suggesting their independent prognostic value. miR-29a-3p targeted THBS2 expression via a direct anti-fibrotic effect on PAH-induced cardiac fibrosis, indicating miR-29a-3p acts as a messenger with promising therapeutic effects.