To estimate stereotactic ablative radiation therapy (SABR) efficacy and its potential role as an alternative to surgery for the treatment of lung metastases from colorectal cancer.
Forty consecutive ...patients who received SABR as first local therapy at the time of lung progression were included, from 2004 to 2014. The primary study endpoint was overall survival. Secondary endpoints were progression-free survival and safety.
A single nodule was treated in 26 patients (65%), 2 nodules in 10 patients (25%), 3 in 3 patients (7.5%), and 4 in 1 patient (2.5%), for a total of 59 lesions. The median delivered biological effective dose was 96 Gy, in 1 to 8 daily fractions. Median follow-up time was 20 months (range, 3-72 months). Overall survival rates at 1, 2, and 5 years were, respectively, 84%, 73%, and 39%, with 14 patients (35%) dead. Median overall survival was 46 months. Progression occurred in 25 patients (62.5%), at a median interval of 8 months; failure at SABR site was observed in 3 patients (7.5%). Progression-free survival rates were 49% and 27% at 1 and 2 years, respectively.
The results of this retrospective exploratory analysis suggest safety and efficacy of SABR in patients affected with colorectal cancer lung oligometastases and urge inclusion of SABR in prospective clinical trials.
Abstract Patients affected with early stage (IA–IB) non-small cell lung cancer (NSCLC), deemed medically inoperable, are usually treated by conventional 3D-CRT, with poor results in terms of local ...tumour control and survival. Hypofractionated stereotactic body radiation therapy (SBRT) appears to be a valid alternative option, with high rates of local control and promising survival rates according to recent reported series. We herein report the final results of a prospective phase II trial of SBRT in 62 stage I NSCLC patients, homogeneously treated with three fractions of 15 Gy each, given every other day during a 1 week time, up to a total dose of 45 Gy; dose was prescribed to the 80%-isodose encompassing planning target volume. Patients were immobilized in a dedicated stereotactic body frame; margins around gross tumour volume were 5 mm in the axial plane and 10 mm in the longitudinal direction. Median age was 73.7 years. A pathologic confirmation of NSCLC was obtained in 64.5% of patients. Forty-three patients had stage IA and 19 stage IB disease. The majority of patients did not experience any toxicity; mild skin reactions, fatigue, dyspnea/cough or transient thoracic pain were recorded in approximately 10% of patients. With a median follow-up time of 28 months, 2 patients experienced an isolated local relapse, 4 an isolated nodal relapse and 15 a systemic failure. At 3 years, local control rate was 87.8%, cancer-specific survival 72.5%, overall survival 57.1%, with 8 out of 20 non-cancer related deaths. In multivariate analysis, tumour volume was associated with a better outcome. In our series, SBRT was well tolerated and confirmed its efficacy, with local control and survival rates globally superior to those reported using conventional radiotherapy. A longer follow-up is needed in order to establish a correct comparison with surgical series, and to fully ascertain a potential negative impact of SBRT on comorbidities of such a fragile patients population.
The purpose of this study was to evaluate the risks of second cancers and cardiovascular diseases associated with an optimized volumetric modulated arc therapy (VMAT) planning solution in a selected ...cohort of stage I/II Hodgkin lymphoma (HL) patients treated with either involved-node or involved-site radiation therapy in comparison with 3-dimensional conformal radiation therapy (3D-CRT).
Thirty-eight patients (13 males and 25 females) were included. Disease extent was mediastinum alone (n=8, 21.1%); mediastinum plus unilateral neck (n=19, 50%); mediastinum plus bilateral neck (n=11, 29.9%). Prescription dose was 30 Gy in 2-Gy fractions. Only 5 patients had mediastinal bulky disease at diagnosis (13.1%). Anteroposterior 3D-CRT was compared with a multiarc optimized VMAT solution. Lung, breast, and thyroid cancer risks were estimated by calculating a lifetime attributable risk (LAR), with a LAR ratio (LAR(VMAT)-to-LAR(3D-CRT)) as a comparative measure. Cardiac toxicity risks were estimated by calculating absolute excess risk (AER).
The LAR ratio favored 3D-CRT for lung cancer induction risk in mediastinal alone (P=.004) and mediastinal plus unilateral neck (P=.02) presentations. LAR ratio for breast cancer was lower for VMAT in mediastinal plus bilateral neck presentations (P=.02), without differences for other sites. For thyroid cancer, no significant differences were observed, regardless of anatomical presentation. A significantly lower AER of cardiac (P=.038) and valvular diseases (P<.0001) was observed for VMAT regardless of disease extent.
In a cohort of patients with favorable characteristics in terms of disease extent at diagnosis (large prevalence of nonbulky presentations without axillary involvement), optimized VMAT reduced heart disease risk with comparable risks of thyroid and breast cancer, with an increase in lung cancer induction probability. The results are however strongly influenced by the different anatomical presentations, supporting an individualized approach.
Abstract Introduction Stereotactic body radiation therapy (SBRT) has an emerging role in patients affected with pulmonary metastases. Purpose of this study was to evaluate efficacy and tolerability ...of SBRT in a cohort of patients treated between 2003 and 2009 at our institution. Methods A total of 61 patients with oligometastatic lung tumors (single pulmonary nodules in 73.7%) were included in the study. SBRT was performed with a stereotactic body frame and a 3D-conformal technique. Fifty-one patients received 26 Gy in 1 fraction, 22 a dose of 45 Gy in 3 fractions and 3 a dose of 36 Gy in 4 fractions. Primary tumor was lung cancer in 45.7% of patients, colorectal cancer in 21.3% and a variety of other origins in 33%. The primary endpoint was local control, secondary endpoints were survival and toxicity. Results After a median follow-up interval of 20.4 months, local control rates at 2 and 3 years were 89% and 83.5%, overall survival 66.5% and 52.5%, cancer-specific survival 75.4% and 67%, progression-free survival 32.4% and 22.3%. Tumor volume was significantly associated to survival, with highest rates in patients with single small tumors. Median survival time was 42.8 months, while median progression-free survival time was 11.9 months. Toxicity profiles were good, with just one case of grade III toxicity (pneumonitis). Conclusion This study shows that SBRT is an effective and safe local treatment option for patients with lung metastases. Definitive results are strictly correlated to clinical selection of patients.
Abstract
Electron- (ECWC) and ion- (ICWC) cyclotron wall conditioning are essential means for controlled fusion to modify the surface state of plasma-facing components in order to reduce impurity ...generation and fuel accumulation in the wall. Development of ECWC and ICWC requires characterization of neutral particle fluxes generated in discharges, because neutrals enhance the homogeneity of the conditioning, which may contribute to remote or shadowed areas, especially in the presence of a permanent magnetic field (e.g. W7-X, ITER). A time-of-flight neutral particle analyzer (ToF-NPA) with 4.07 m flight distance is employed to measure time- and energy-resolved low energetic (<1 keV) neutral particle distributions. The ToF-NPA setup tested at the EXTRAP T2R reversed field pinch was installed at the TOMAS toroidal plasma facility to determine low energy neutral particle fluxes while investigating the impact of the gas pressure in the instrument and compatibility with low count rates during EC- and ICWC discharges. TOMAS has a major radius of 0.78 m and provides various plasma operation conditions: toroidal magnetic field up to 0.12 T, EC frequency 2.45 GHz with the power of 0.6–6 kW, IC frequency of 10–50 MHz with the power of up to 6 kW. Early results on the characterization of three phases (EC only, EC + IC, and IC only) of hydrogen discharges demonstrate: (i) the low energy (10–725 eV) neutrals distribution has been determined by the NPA system, (ii) the mixed EC + IC phase produces the highest population of neutral particles, while the EC only provides one order of magnitude lower rate, (iii) the neutrals produced in IC only have higher average energy (28 eV) than EC only (7 eV) and EC + IC (16 eV).
Image-guided intensity modulated radiation therapy (IG-IMRT) allows for margin reduction and highly conformal dose distribution, with consistent advantages in sparing of normal tissues. The purpose ...of this retrospective study was to compare involved-site IG-IMRT with involved-site 3D conformal RT (3D-CRT) in the treatment of early stage Hodgkin lymphoma (HL) involving the mediastinum, with efficacy and toxicity as primary clinical endpoints.
We analyzed 90 stage IIA HL patients treated with either involved-site 3D-CRT or IG-IMRT between 2005 and 2012 in 2 different institutions. Inclusion criteria were favorable or unfavorable disease (according to European Organization for Research and Treatment of Cancer criteria), complete response after 3 to 4 cycles of an adriamycin- bleomycin-vinblastine-dacarbazine (ABVD) regimen plus 30 Gy as total radiation dose. Exclusion criteria were chemotherapy other than ABVD, partial response after ABVD, total radiation dose other than 30 Gy. Clinical endpoints were relapse-free survival (RFS) and acute toxicity.
Forty-nine patients were treated with 3D-CRT (54.4%) and 41 with IG-IMRT (45.6%). Median follow-up time was 54.2 months for 3D-CRT and 24.1 months for IG-IMRT. No differences in RFS were observed between the 2 groups, with 1 relapse each. Three-year RFS was 98.7% for 3D-CRT and 100% for IG-IMRT. Grade 2 toxicity events, mainly mucositis, were recorded in 32.7% of 3D-CRT patients (16 of 49) and in 9.8% of IG-IMRT patients (4 of 41). IG-IMRT was significantly associated with a lower incidence of grade 2 acute toxicity (P=.043).
RFS rates at 3 years were extremely high in both groups, albeit the median follow-up time is different. Acute tolerance profiles were better for IG-IMRT than for 3D-CRT. Our preliminary results support the clinical safety and efficacy of advanced RT planning and delivery techniques in patients affected with early stage HL, achieving complete response after ABVD-based chemotherapy.
An upgraded version of the fast semi-analytical code ANTITER is used to model the refueled TWA sections of any arbitrary number of straps facing a low coupling plasma profile. The code computes the ...Y, Z and S matrices of the antenna array from which the performances of the TWA sections and of their feeding system are deduced as a function of the geometry of the TWA. The model incorporates the feeding of the section by a resonant ring circuit recirculating the output power of each section. Approximate scaling laws guiding the design are derived for the antenna main parameters. A first optimization of the design for the DEMO antenna section is made and the resulting power capability of a DEMO system evaluated.
•The automation of the planning seems be the next step of the radiotherapy.•A comparison between Auto-Planning and different manual planning was carried out.•The Auto-Planning provides plans of good ...quality and comparable to manual ones.•The time required for planning with Auto-Planning module was mainly reduced.
Automated treatment planning is a new frontier in radiotherapy. The Auto-Planning module of the Pinnacle3 treatment planning system (TPS) was evaluated for liver stereotactic body radiation therapy treatments.
Ten cases were included in the study. Six plans were generated for each case by four medical physics experts. The first two planned with Pinnacle TPS, both with manual module (MP) and Auto-Planning one (AP). The other two physicists generated two plans with Monaco TPS (VM). Treatment plan comparisons were then carried on the various dosimetric parameters of target and organs at risk, monitor units, number of segments, plan complexity metrics and human resource planning time. The user dependency of Auto-Planning was also tested and the plans were evaluated by a trained physician.
Statistically significant differences (Anova test) were observed for spinal cord doses, plan average beam irregularity, number of segments, monitor units and human planning time. The Fisher-Hayter test applied to these parameters showed significant statistical differences between AP e MP for spinal cord doses and human planning time; between MP and VM for monitor units, number of segments and plan irregularity; for all those between AP and VM. The two plans created by different planners with AP were similar to each other.
The plans created with Auto-Planning were comparable to the manually generated plans. The time saved in planning enables the planner to commit more resources to more complex cases. The independence of the planner enables to standardize plan quality.
The Gafchromic™ EBT was recently introduced in film dosimetry for external beam therapy (EBT). The high spatial resolution, weak energy dependence, and near-tissue equivalence of EBT films make them ...suitable for measurement of dose distributions in radiotherapy, especially intensity-modulated radiation therapy (IMRT). Starting with a sensitometric curve and dose uncertainty relative to the flatbed scanner, the goal of this study was to find an efficient method of correcting for light scattering, and to compare dose distribution supplied by Gafchromic™ EBT with the distribution obtained with a 2D ion-chamber detector system. Light scattering was analyzed for different levels of dose, and was found to depend on the red-scale value as well as the position of the pixel on the scanner. Many “uniform” films were exposed at different levels of dose to create a two-dimensional matrix correction to take this effect into account. The dose distribution obtained for three clinical beams (
10
×
10
,
15
×
15
cm
open fields and
12
×
12
cm
wedge
60
°
field) were in agreement with those supplied by the 2D array. Gamma index
<
1
(using
5
mm
distance and 5% dose as constraints) for the three fields considered was reached in an average of 98% of the points.
Radiotherapy in Hodgkin's Lymphoma (HL) is currently evolving with new attempts to further reduce radiation volumes to the involved-node concept (Involved Nodes Radiation Therapy, INRT) and with the ...use of intensity modulated radiotherapy (IMRT). Currently, IMRT can be planned and delivered with several techniques, and its role is not completely clear. We designed a planning study on a typical dataset drawn from clinical routine with the aim of comparing different IMRT solutions in terms of plan quality and treatment delivery efficiency.
A total of 10 young female patients affected with early stage mediastinal HL and treated with 30 Gy INRT after ABVD-based chemotherapy were selected from our database. Five different treatment techniques were compared: 3D-CRT, VMAT (single arc), B-VMAT ("butterfly", multiple arcs), Helical Tomotherapy (HT) and Tomodirect (TD). Beam energy was 6 MV, and all IMRT planning solutions were optimized by inverse planning with specific dose-volume constraints on OAR (breasts, lungs, thyroid gland, coronary ostia, heart). Dose-Volume Histograms (DVHs) and Conformity Number (CN) were calculated and then compared, both for target and OAR by a statistical analysis (Wilcoxon's Test).
PTV coverage was reached for all plans (V95% ≥ 95%); highest mean CN were obtained with HT (0.77) and VMAT (0.76). B-VMAT showed intermediate CN mean values (0.67), while the lowest CN were obtained with TD (0.30) and 3D-CRT techniques (0.30). A trend of inverse correlation between higher CN and larger healthy tissues volumes receiving low radiation doses was shown for lungs and breasts. For thyroid gland and heart/coronary ostia, HT, VMAT and B-VMAT techniques allowed a better sparing in terms of both Dmean and volumes receiving intermediate-high doses compared to 3D-CRT and TD.
IMRT techniques showed superior target coverage and OAR sparing, with, as an expected consequence, larger volumes of healthy tissues (lungs, breasts) receiving low doses. Among the different IMRT techniques, HT and VMAT showed higher levels of conformation; B-VMAT and HT emerged as the planning solutions able to achieve the most balanced compromise between higher conformation around the target and smaller volumes of OAR exposed to lower doses (typical of 3D-CRT).