The development of orthogonal acceleration time-of-flight (oa-tof) technology is driven forward due to higher mass accuracy and resolving power than conventional linear/reflectron tof instruments. ...This is achieved with a more accurate definition of starting energies and coordinates of ions by spatial separation of ion generation and orthogonal ion extraction. Consequently, the ability to cover the whole mass spectral range without scanning is not given anymore. Therefore, continuous ion sources are favored for ensuring high duty cycles and thus high temporal resolution. For pulsed ion sources, high repetition rates are mandatory for covering large
m
/
z
ranges without losing their high temporal resolution. We have combined an oa-tof with deuterium lamp single-photon ionization (SPI) as a continuous ion source together with a pulsed 2000 Hz excimer (KrF) laser for resonance enhanced multi-photon ionization (REMPI). These two ionization techniques can be used simultaneously. To the best of our knowledge, this system is the first of its kind in combining a vacuum pulsed ionization source with an oa-tof instrument without any other ion storage hardware. The combination of a soft broadband ionization for organics (SPI) in combination with a very sensitive and selective soft ionization (REMPI) can be used for covering the whole mass range or in targeted on-line monitoring cases one or several smaller mass ranges. To demonstrate the simultaneous SPI/REMPI-oa-tof technique, two applicative areas are explored: on-line monitoring of coffee roast gas emissions and e-cigarette vapor. The complementary information from SPI and REMPI signals are combined in a way to exploit the advantages of both ionization types. In a further development step, a second data acquisition card is built into the system. This modification allows the independent storage of data from both ionization methods without mixing. For demonstration, a third example with a GC measurement is provided. The last example shows the possibility of modified sensitivities for different mass regions in REMPI data acquisition without affecting the SPI channel. The newly developed system shows high robustness in terms of measurements in real industrial environments. The simultaneous measurement technique provides a higher density of information in a single measurement, saving time and resources.
New instrumental development for robust process monitoring with two soft ionization methods working in parallel.
•Generic ecosystem service classification been tailored for the marine environment.•Need for indicators of ecosystem services, functions and benefits is highlighted.•Indicators were assessed for ...their relevance in application to the Dogger Bank.•Lack of indicator specificity, spatial disconnect and uncertainty are challenging.•Potential to apply ecosystem service indicators to positive effect is recognized.
There is a multitude of ecosystem service classifications available within the literature, each with its own advantages and drawbacks. Elements of them have been used to tailor a generic ecosystem service classification for the marine environment and then for a case study site within the North Sea: the Dogger Bank. Indicators for each of the ecosystem services, deemed relevant to the case study site, were identified. Each indicator was then assessed against a set of agreed criteria to ensure its relevance and applicability to environmental management. This paper identifies the need to distinguish between indicators of ecosystem services that are entirely ecological in nature (and largely reveal the potential of an ecosystem to provide ecosystem services), indicators for the ecological processes contributing to the delivery of these services, and indicators of benefits that reveal the realized human use or enjoyment of an ecosystem service. It highlights some of the difficulties faced in selecting meaningful indicators, such as problems of specificity, spatial disconnect and the considerable uncertainty about marine species, habitats and the processes, functions and services they contribute to.
Chronic kidney disease (CKD) is characterized by an exceptionally high mortality rate, primarily due to cardiovascular disease. Reduced soluble TNF-like weak inducer of apoptosis (sTWEAK) plasma ...levels have been reported both in patients with subclinical atherosclerosis and CKD.
A cross-sectional study was conducted in 218 prevalent patients (121 men; 63 +/- 14 yr) undergoing hemodialysis (HD). sTWEAK levels in relation with the patients' outcome were studied.
sTWEAK plasma levels were 208 (165 to 272) pg/ml, median interquartile range, significantly lower than healthy controls (P < 0.0001). sTWEAK was negatively associated with inflammatory markers, such as C-reactive protein and IL-6. Overall mortality was assessed after an average follow-up of 31 mo, during which 81 patients died. After controlling for potential confounding variables, patients in the upper tertile of sTWEAK plasma levels had an increased risk of cardiovascular and all-cause mortality. A significant interaction effect between sTWEAK and IL-6 levels was found synergy index: 2.19 (0.80, 5.93). Thus, the association of sTWEAK with mortality was strongest in patients with inflammation (defined as IL-6 > 7.0 pg/ml), in whom high sTWEAK strongly predicted cardiovascular and all-cause mortality. These results were confirmed in a second cohort of HD patients.
The concurrent presence of elevated sTWEAK plasma concentrations and an inflammatory environment have additive effects on mortality in HD patients. Further studies on the potential different role of sTWEAK in health and disease are warranted.
There is growing evidence that cytokines such as tumor necrosis factor (TNF) alpha, interleukin (IL) 1beta, IL-6, bone morphogenetic proteins (BMP), and nitric oxide (NO) play an important role in ...the pathogenesis of bone tunnel enlargement following anterior cruciate ligament (ACL) reconstruction. Furthermore, the release of these mediators has been considered a possible reason for the higher incidence of bone tunnel enlargement following hamstring tendon (HST) than following patellar tendon (PT) ACL reconstruction observed in several studies. In this investigation synovial fluid samples from 13 patients were collected immediately before (24+/-7 days after ACL rupture) and 7 days after ACL surgery and values of TNF-alpha, IL-1beta, IL-6, NO, and BMP-2 were analyzed. Furthermore, the incidence of bone tunnel enlargement was assessed using radiographs 38+/-7 weeks after surgery. Six patients underwent autologous HST ACL reconstruction, and in seven patients an PT autograft was used. In the overall patient population there were significantly higher synovial fluid concentrations of IL-6 and BMP-2 postoperatively than preoperatively; TNF-alpha showed a trend towards lower postoperative levels while IL-1beta and NO remained unchanged. The concentrations of NO, TNF-alpha, and IL-6 found in the present study were clearly higher than normal values given in the literature. Assessment of bone tunnel enlargement revealed an average increase in tibial tunnel width of 28.4+/-3.1% with comparable values for HST and PT ACL reconstructions. There was no significant correlation between bone tunnel enlargement and postoperative synovial fluid concentrations of TNF-alpha, IL-1beta, IL-6, NO, and BMP-2. However, all patients with bone tunnel enlargement had higher postoperative concentrations of TNF-alpha, IL-6, and NO in the synovial fluid. There were no significant differences in concentrations between HST and PT groups. In conclusion, we observed an association between tibial bone tunnel enlargement and elevated synovial fluid concentrations of IL-6, TNF-alpha, and NO 7 days after ACL surgery indicating the potential involvement of these biological mediators in the pathogenesis of bone tunnel enlargement. However, there was no difference between HST and PT ACL reconstructions regarding synovial fluid contents of IL-6, TNF-alpha, IL-1beta, NO, and BMP-2, suggesting a comparable biological response between these autografts following their use in ACL reconstruction.
This book constitutes the refereed proceedings of the First International Conference of Abstract State Machines, B and Z, ABZ 2008, held in London, UK, in September 2008. The conference ...simultaneously incorporated the 15th International ASM Workshop, the 17th International Conference of Z Users and the 8th International Conference on the B Method. The 44 revised full papers presented together with 4 invited contributions were carefully reviewed and selected from numerous submissions. The conference fosters the cross-fertilization of three rigorous methods for the design and analysis of hardware and software systems - both in academia and industry - namely Abstract State Machines, B, and Z. Covering a wide range of research spanning from theoretical and methodological foundations to tool support and practical applications, the contributions are organized in topical sections on abstract state machines, B papers, Z papers, ABZ short papers, and the papers of the Verified Software Repository Network (VSR-net) workshop.