Display omitted
•Multi-reflection time-of-flight mass separator for purification of radioactive ion beams.•Enhanced ion beam purification by stacking of multiple cleaned ion samples in an ...intermediate ion trap to increase the signal intensity of Penning trap mass measurements.•Multi-reflection time-of-flight mass spectrometer for high-precision mass measurements of short-lived species.•Multi-reflection time-of-flight mass analyzer for target and ion-source development of exotic beams.
The online precision mass spectrometer ISOLTRAP at ISOLDE/CERN was recently upgraded by adding a multi-reflection time-of-flight mass separator/spectrometer (MR-ToF MS) between the linear radio-frequency ion trap and the two Penning traps already in place. As a mass separator, the MR-ToF device has improved significantly ISOLTRAP's capability of purification of contaminated ion beams. In addition, the MR-ToF MS can be operated as a mass spectrometer, either to analyze the ISOLDE ion beam or for precision mass measurements of nuclides that are shorter-lived or that have lower yields than those accessible for Penning-trap mass spectrometry. The MR-ToF MS and corresponding components, its integration into ISOLTRAP, and its various operation modes are reviewed. Furthermore, a precision measurement of the 137Eu mass is presented, determined with the help of the MR-ToF device as a mass separator.
Display omitted
•A new ion selection technique based on multi-reflection time-of-flight mass separation is introduced and characterized.•No further devices, such as ion gates, are needed for beam ...purification.•Several offline and online examples with short-lived nuclei are presented for illustration.
A method for high-resolution mass selection is presented which makes use of a multi-reflection time-of-flight mass spectrometer with in-trap lift. The new method needs no additional gating or deflection components. The concept is described in detail and demonstrated with both offline and online measurements on short-lived nuclides performed with ISOLTRAP at ISOLDE/CERN.
A multi-reflection time-of-flight (MR-ToF) mass analyzer has been integrated into ISOLTRAP, the precision mass spectrometer for on-line mass determinations of short-lived nuclides at ISOLDE/CERN. The ...new instrument improves ISOLTRAP by providing a fast separation of isobaric contaminant species as well as subsequent ion selection using the fast Bradbury–Nielsen gate. Suppression ratios of up to 104 and mass-resolving powers of over 105 have been reached in off-line experiments. Preliminary data from on-line applications illustrate the benefit and performance of the device and its potential in the context of the ISOLTRAP setup.
In rare cases, the removal of a single proton (Z) or neutron (N) from an atomic nucleus leads to a dramatic shape change. These instances are crucial for understanding the components of the nuclear ...interactions that drive deformation. The mercury isotopes (Z = 80) are a striking example1,2: their close neighbours, the lead isotopes (Z = 82), are spherical and steadily shrink with decreasing N. The even-mass (A = N + Z) mercury isotopes follow this trend. The odd-mass mercury isotopes 181,183,185Hg, however, exhibit noticeably larger charge radii. Due to the experimental difficulties of probing extremely neutron-deficient systems, and the computational complexity of modelling such heavy nuclides, the microscopic origin of this unique shape staggering has remained unclear. Here, by applying resonance ionization spectroscopy, mass spectrometry and nuclear spectroscopy as far as 177Hg, we determine 181Hg as the shape-staggering endpoint. By combining our experimental measurements with Monte Carlo shell model calculations, we conclude that this phenomenon results from the interplay between monopole and quadrupole interactions driving a quantum phase transition, for which we identify the participating orbitals. Although shape staggering in the mercury isotopes is a unique and localized feature in the nuclear chart, it nicely illustrates the concurrence of single-particle and collective degrees of freedom at play in atomic nuclei.
The recently confirmed neutron-shell closure at N=32 has been investigated for the first time below the magic proton number Z=20 with mass measurements of the exotic isotopes (52,53)K, the latter ...being the shortest-lived nuclide investigated at the online mass spectrometer ISOLTRAP. The resulting two-neutron separation energies reveal a 3 MeV shell gap at N=32, slightly lower than for 52Ca, highlighting the doubly magic nature of this nuclide. Skyrme-Hartree-Fock-Bogoliubov and ab initio Gorkov-Green function calculations are challenged by the new measurements but reproduce qualitatively the observed shell effect.
The masses of ^{246}Es, ^{251}Fm, and the transfermium nuclei ^{249-252}Md and ^{254}No, produced by hot- and cold-fusion reactions, in the vicinity of the deformed N=152 neutron shell closure, have ...been directly measured using a multireflection time-of-flight mass spectrograph. The masses of ^{246}Es and ^{249,250,252}Md were measured for the first time. Using the masses of ^{249,250}Md as anchor points for α decay chains, the masses of heavier nuclei, up to ^{261}Bh and ^{266}Mt, were determined. These new masses were compared with theoretical global mass models and demonstrated to be in good agreement with macroscopic-microscopic models in this region. The empirical shell gap parameter δ_{2n} derived from three isotopic masses was updated with the new masses and corroborates the existence of the deformed N=152 neutron shell closure for Md and Lr.
A newly assembled multi-reflection time-of-flight mass spectrograph (MRTOF-MS) at RIKEN’s RIBF facility became operational for the first time in spring 2020; further modifications and performance ...tests using stable ions were completed in early 2021. By using a pulsed-drift-tube technique to modify the ions’ kinetic energy in a wide range, we directly characterize the dispersion function of the system for use in a new procedure for optimizing the voltages applied to the electrostatic mirrors. Thus far, a mass resolving power of Rm>1000000 is reached within a total time-of-flight of only 12.5ms, making the spectrometer capable of studying short-lived nuclei possessing low-lying isomers. Detailed information about the setup and measurement procedure is reported, and an alternative in-MRTOF ion selection scheme to remove molecular contaminants in the absence of a dedicated deflection device is introduced. The setup underwent an initial on-line commissioning at the BigRIPS facility at the end of 2020, where more than 70 nuclear masses have been measured. A summary of the commissioning experiments and results from a test of mass accuracy will be presented.
In applied forms of time-of-flight mass spectrometry utilizing ion storage devices prior to an analysis device, a non instantaneous electric ejection pulse applied in the region of ion storage is ...used to accelerate ions into the time-of-flight analyzer. The calculated mass value of the ions from the time-of-flight is dependent on the duration of the field transition up to full strength. For novel applications dedicated to precision measurements, such as multi-reflection time-of-flight mass spectrometry of short-lived isotopes, the goal is to continuously decrease the measurement uncertainty while providing a mass accuracy on the same order. Even though dynamic-field models for time-of-flight mass spectrometry have been considered in the past for technological advances, it is important to study the accuracy of the measured mass in this context. Using a simplified linear model for the field transition, we provide a basic investigation of the scenario, and discuss the deviation from the classical “mass-over-charge” dependency of the ions’ time-of-flight, which becomes violated. The emerging mass discrepancy depends on the distance between the mass of the ion used for calibration and that of the ion of interest and, in extreme cases, can increase to about one percent for systems with short times-of-flight. However, for typical conditions in single-reference multi-reflection time-of-flight mass spectrometry, mass deviations caused by this effect typically remain below the 1ppm level. If a mass calibration using two or more ion species is possible during the measurement, the effect becomes negligible for appropriate choices of reference masses.
Display omitted
The neutron-rich isotopes Cr58–63 were produced for the first time at the ISOLDE facility and their masses were measured with the ISOLTRAP spectrometer. The new values are up to 300 times more ...precise than those in the literature and indicate significantly different nuclear structure from the new mass-surface trend. A gradual onset of deformation is found in this proton and neutron midshell region, which is a gateway to the second island of inversion around N=40. In addition to comparisons with density-functional theory and large-scale shell-model calculations, we present predictions from the valence-space formulation of the ab initio in-medium similarity renormalization group, the first such results for open-shell chromium isotopes.
A multi-reflection time-of-flight (MR-ToF) device has been set up for the development and test of new MR-ToF techniques and for future applications in atomic cluster research. The instrument, ...consisting of a laser-ablation ion source, a quadrupole bender, the MR-ToF analyzer (with ion mirrors and in-trap lift), and a channeltron detector, is described in detail and characterized with respect to preliminary results of its performance parameters. In addition, cluster ions were mass selected in the MR-ToF device and photodissociated. The charged fragments were stored and mass analyzed in a proof-of-principle MS/MS experiment where both MS steps were performed in the MR-ToF operation mode.
Display omitted
•A new multi-reflection time-of-flight device for applications in cluster and trap research has been setup.•The experiment is presented in detail, including geometrical dimensions, experimental processes, trapping techniques and typical parameters.•Cluster ions are mass analyzed with a mass resolving power of R > 200 000.•Clusters are photodissociated in a proof-of-principle MS/MS experiment, with just the MR-ToF operation mode.