Charged-particle tracking in the international Muon Ionisation Cooling Experiment (MICE) will be performed using two solenoidal spectrometers, each instrumented with a tracking detector based on ...350μm diameter scintillating fibres. The design and construction of the trackers is described along with the quality-assurance procedures, photon-detection system, readout electronics, reconstruction and simulation software and the data-acquisition system. Finally, the performance of the MICE tracker, determined using cosmic rays, is presented.
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF3I and located in the SNOLAB underground laboratory. PICO-60 is the largest ...bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C3F8 bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining 48.2% of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.
The layer 0 inner silicon detector of the D0 experiment Angstadt, R.; Bagby, L.; Bean, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/2010, Letnik:
622, Številka:
1
Journal Article
Recenzirano
Odprti dostop
This paper describes the design, fabrication, installation and performance of the new inner layer called Layer 0 (L0) that was inserted in the existing Run IIa silicon micro-strip tracker (SMT) of ...the D0 experiment at the Fermilab Tevatron p¯p collider. L0 provides tracking information from two layers of sensors, which are mounted with center lines at a radial distance of 16.1 and 17.6mm from the beam axis. The sensors and read-out electronics are mounted on a specially designed and fabricated carbon fiber structure that includes cooling for sensor and read-out electronics. The structure has a thin polyimide circuit bonded to it so that the circuit couples electrically to the carbon fiber allowing the support structure to be used both for detector grounding and a low impedance connection between the remotely mounted hybrids and the sensors.
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C3F8 located in the SNOLAB underground laboratory. As in previous PICO bubble ...chambers, PICO-60C3F8 exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than one event per month.
The D0 Silicon Microstrip Tracker Ahmed, S.N.; Aoki, M.; Åsman, B. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/2011, Letnik:
634, Številka:
1
Journal Article
Recenzirano
Odprti dostop
This paper describes the mechanical design, the readout chain, the production, testing and the installation of the Silicon Microstrip Tracker of the D0 experiment at the Fermilab Tevatron collider. ...In addition, we describe the performance and operational experience of the detector during the experiment data collection between 2001 and 2010.
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C3F8 located in the SNOLAB underground laboratory. As in previous PICO bubble ...chambers, PICO-60 C3F8 exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than one event per month. A blind analysis of an efficiency-corrected 1167-kg day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. In conclusion, these results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.4×10-41 cm2 for a 30-GeV c-2 WIMP, more than 1 order of magnitude improvement from previous PICO results.
We reported new data from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF3I and located in the SNOLAB underground laboratory. PICO-60 is the largest ...bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 live-days, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C3F8 bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. We found these behaviors allow for analysis cuts to remove all background events while retaining 48.2%of the exposure. Stringent limits on WIMPs interacting via spin-dependent proton and spin-independent processes are set, and the interpretation of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei is ruled out.
The design of the new D0 forward angle muon tracking detector and its gas system are described in this paper. The new D0 forward muon tracking detector is based on a minidrift tube technology. The ...minidrift tubes are operated in proportional mode using a fast nonflammable gas mixture. The basic operational characteristics of this gas mixture and the effects of impurities are presented. Special requirements of the gas system that lead to our design choices are discussed. The gas distribution, recirculation, control, and monitoring system are described.