Liquid argon calorimeter performance at high rates Glatte, A.; Kobel, M.; Mader, W.F. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
03/2012, Letnik:
669
Journal Article
Recenzirano
We project the performance of the ATLAS liquid argon endcap and forward calorimeters at the planned high luminosity LHC option HL-LHC by exposing small calorimeter modules of the electromagnetic, ...hadronic, and forward calorimeters to high intensity beams at IHEP/Protvino. The beam intensity extends well beyond the maximum expected for these calorimeters at HL-LHC. The signal reconstruction and calorimeter performance have been studied in full detail.
The validation of GEANT4 physics models is done by comparing experimental data from beam tests of modules of the ATLAS hadronic end-cap calorimeter with GEANT4 based simulations. Various physics ...lists for the simulation of hadronic showers are evaluated. We present results of studies of the calorimeter performance parameters (like energy resolution and shower shapes) as well as results of investigations of the influence of the Birks' law and of cuts on the time of development of hadronic showers.
We evaluate the validity of the GEANT4 electromagnetic and hadronic physics models by comparing experimental data from beam tests of modules of the ATLAS hadronic end-cap calorimeter with ...GEANT4-based simulations. Two physics lists (LHEP and QGSP) for the simulation of hadronic showers are evaluated. Calorimeter performance parameters like the energy resolution and shapes of showers are studied both for electrons and charged pions. Furthermore, throughout the paper we compare GEANT4 and the corresponding predictions of GEANT3 used with the G-CALOR code for hadronic shower development.
The local hadronic calibration scheme developed for the reconstruction and calibration of jets and missing transverse energy in ATLAS has been evaluated using data obtained during combined beam tests ...of modules of the ATLAS liquid argon endcap and forward calorimeters. These tests covered the pseudorapidity range of 2.5<|η|<4.0. The analysis has been performed using special sets of calibration weights and corrections obtained with the Geant4 simulation of a detailed beam-test setup. The evaluation itself has been performed through the careful study of specific calorimeter performance parameters such as e.g. energy response and resolution, shower shapes, as well as different physics lists of the Geant4 simulation.
The local hadronic calibration scheme developed for the reconstruction and calibration of jets and missing transverse energy in ATLAS has been evaluated using data obtained during combined beam tests ...of modules of the ATLAS liquid argon endcap and forward calorimeters. These tests covered the pseudorapidity range of 2.5 < | ? | < 4.0 . The analysis has been performed using special sets of calibration weights and corrections obtained with the Geant4 simulation of a detailed beam-test setup. The evaluation itself has been performed through the careful study of specific calorimeter performance parameters such as e.g. energy response and resolution, shower shapes, as well as different physics lists of the Geant4 simulation.
A full azimuthal
φ
-wedge of the ATLAS liquid argon end-cap calorimeter has been exposed to beams of electrons, muons and pions in the energy range
6
GeV
⩽
E
⩽
200
GeV
at the CERN SPS. The angular ...region studied corresponds to the ATLAS impact position around the pseudorapidity interval
1.6
<
|
η
|
<
1.8
. The beam test setup is described. A detailed study of the performance is given as well as the related intercalibration constants obtained. Following the ATLAS hadronic calibration proposal, a first study of the hadron calibration using a weighting ansatz is presented. The results are compared to predictions from Monte Carlo simulations, based on GEANT 3 and GEANT 4 models.
Ultrasonographic examination of the fetal face can provide information that may lead to the diagnosis of anomalies in other organs or systems. Thus, the fetal face represents a “diagnostic window” ...for fetal diseases and syndromes. Three-dimensional ultrasonography (3DUS) improves the evaluation of anatomic fetal facial anomalies over what is possible by 2-dimensional ultrasonography (2DUS). Four-dimensional ultrasonography (4DUS), by adding the temporal component to the examination, allows visualization of facial expressions that might be useful in the study of fetal behavior and maternal-fetal bonding. In this article, we evaluate the potential of 3D/4DUS for the study of structural and functional development of the fetal face.