Background
Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE ...neo. However, there are no studies that have reviewed and compared the long‐term clinical and hemodynamic outcomes of these patients.
Aims
This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real‐world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long‐term effectiveness.
Methods
A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second‐generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow‐up were compared between the two generations.
Results
A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para‐valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para‐valvular regurgitation, which remained significant at 1 year.
Conclusion
The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.
BACKGROUNDSevere tricuspid regurgitation (TR) is frequently associated with significant morbidity and mortality; such patients are often deemed to be at high surgical risk. Heterotopic bicaval ...stenting is an emerging, attractive transcatheter solution for these patients. OBJECTIVESThe aim of this study was to evaluate the 30-day safety and 6-month efficacy outcomes of specifically designed bioprosthetic valves for the superior and inferior vena cava. METHODSTRICUS EURO (Safety and Efficacy of the TricValve® Transcatheter Bicaval Valves System in the Superior and Inferior Vena Cava in Patients With Severe Tricuspid Regurgitation) is a nonblinded, nonrandomized, single-arm, multicenter, prospective trial that enrolled patients from 12 European centers between December 2019 and February 2021. High-risk individuals with severe symptomatic TR despite optimal medical therapy were included. The primary endpoint was quality-of-life (QOL) improvement measured by Kansas City Cardiomyopathy Questionnaire score and New York Heart Association (NYHA) functional class improvement at 6-month follow-up. RESULTSThirty-five patients (mean age 76 ± 6.8 years, 83% women) were treated using the TricValve system. All patients at baseline were in NYHA functional class III or IV. At 30 days, procedural success was 94%, with no procedural deaths or conversions to surgery. A significant increase in QOL at 6 months follow-up was observed (baseline and 6-month Kansas City Cardiomyopathy Questionnaire scores 42.01 ± 22.3 and 59.7 ± 23.6, respectively; P = 0.004), correlating with a significant improvement in NYHA functional class, with 79.4% of patients noted to be in functional class I or II at 6 months (P = 0.0006). The rates of 6-month all-cause mortality and heart failure hospitalization were 8.5% and 20%, respectively. CONCLUSIONSThe dedicated bicaval system for treating severe symptomatic TR was associated with a high procedural success rate and significant improvements in both QOL and functional classification at 6 months follow-up.
We present the case of a 71-year-old woman with rheumatic valvular disease who underwent mitro-aortic mechanical valve replacement and tricuspid annuloplasty in 2011. She required a dual-chamber ...pacemaker in 2012 and developed severe tricuspid regurgitation (TR), leading to percutaneous annuloplasty with Cardioband® system in 2021.We present the case of a 71-year-old woman with rheumatic valvular disease who underwent mitro-aortic mechanical valve replacement and tricuspid annuloplasty in 2011. She required a dual-chamber pacemaker in 2012 and developed severe tricuspid regurgitation (TR), leading to percutaneous annuloplasty with Cardioband® system in 2021.
This study sought to investigate the clinical impact of the use of intravascular ultrasound (IVUS) during revascularization of patients with left main coronary artery (LM) disease with drug-eluting ...stents (DES).
Whether the use of IVUS during the procedure adds a clinical benefit remains unclear. There is only 1 previous observational study, with relevant limitations, supporting the value of this strategy.
We performed a patient-level pooled analysis of 4 registries of patients with LM disease treated with DES in Spain. A propensity score-matching method was used to obtain matched pairs of patients with and without IVUS guidance.
A total of 1,670 patients were included, and 505 patients (30.2%) underwent DES implantation under IVUS guidance (IVUS group). By means of the matching method, 505 patients without the use of IVUS during revascularization were selected (no-IVUS group). Survival free of cardiac death, myocardial infarction, and target lesion revascularization at 3 years was 88.7% in the IVUS group and 83.6% in the no-IVUS group (p = 0.04) for the overall population, and 90% and 80.7%, respectively (p = 0.03), for the subgroups with distal LM lesions. The incidence of definite and probable thrombosis was significantly lower in the IVUS group (0.6% vs. 2.2%; p = 0.04). Finally, IVUS-guided revascularization was identified as an independent predictor for major adverse events in the overall population (hazard ratio: 0.70, 95% confidence interval: 0.52 to 0.99; p = 0.04) and in the subgroup with distal lesions (hazard ratio: 0.54, 95% confidence interval: 0.34 to 0.90; p = 0.02).
The results of this pooled analysis show an association of IVUS guidance during percutaneous coronary intervention with better outcomes in patients with LM disease undergoing revascularization with DES.
Abstract
Aims
The optimal management of severe tricuspid regurgitation (TR) remains controversial. While right ventricular systolic function is an established prognostic marker of outcomes, the ...potential role of right atrial (RA) function is unknown. This study aimed to describe RA function by 2D speckle-tracking echocardiography (STE) in at least severe TR and to evaluate its potential association with cardiovascular outcomes.
Methods and results
Consecutive patients with at least (≥) severe TR (severe, massive, or torrential TR) evaluated in the Heart Valve Clinic following a comprehensive clinical protocol were included. Consecutive control subjects and patients with permanent isolated atrial fibrillation (AF) were included for comparison (control and AF group, respectively). RA function was measured with 2D-STE and two components of RA function were calculated: reservoir (RASr) and contractile (RASct) strain (AutoStrain, Philips Medical Systems the EPIQ system). A combined endpoint of hospital admission due to heart failure (HF) or all-cause mortality was defined. Patients with ≥ severe TR (n = 140) showed lower RASr compared with controls (n = 20) and with the AF group (n = 20) (P < 0.001). Atrial TR showed lower RASr compared with other aetiologies of TR (P < 0.001). After a median follow-up of 2.2 years (IQR: 12–41 months), RASr remained an independent predictor of mortality and HF. A cut-off value of RASr of <9.4% held the best accuracy to predict outcomes.
Conclusion
RA function by 2D-STE independently predicts mortality and HF hospitalizations in patients with ≥ severe TR.
Graphical Abstract
Graphical Abstract
2D-STE, 2D speckle-tracking echocardiography; RASr, right atrial reservoir strain; RASct, right atrial contractile strain; AF, atrial fibrillation.