Abstract
Experimental beamlines often are regularly reconfigured to meet changing requirements of the experiments and to minimize beam losses. The configuration is usually done with the help of beam ...optics tools like MADX. These tools offer matching capabilities which allow to find solutions in terms of quadrupole strengths. However, such solutions are found by satisfying the given constraints only and do not take into account limited precision of actual quadrupole devices. Under the influence of quadrupole errors due to magnetic hysteresis, power converter trips etc, the original beamline optics often degrades. This results in beam losses or loss of focus at the experimental target. Readjustment of the optics costs valuable experiment time. Hence, it is desirable to operate a beamline configuration which not only meets the requirements but is also robust against quadrupole errors. Such a configuration will deviate from its nominal properties only by a small margin even when the quadrupole strengths deviate within specified intervals. We present the systematic exploration of beamline configuration space to identify robust configurations. The results are discussed for the BIGKARL beamline at Forschungszentrum Jülich and the findings are supported by experimental data.
Abstract
The Next Ion Medical Machine Study (NIMMS) is an umbrella R&D programme for CERN accelerator technologies targeting advanced accelerator options for proton and light ion therapy. In ...collaboration with the European programme HITRIplus, one area of study is slow extraction which is required to deliver a uniform beam spill for radiotherapy treatment. Several techniques use the third-order resonance to extract hadrons; these include betatron core driven extraction and radiofrequency knock-out. Flexible simulation tools using these techniques were prepared and initially benchmarked with results from the literature that used the Proton-Ion Medical Machine Study (PIMMS) design. The limits of the current PIMMS design were then pushed to evaluate its compatibility to deliver 10x higher intensity ion beams, and using increased extraction rates.
Abstract
The yearly energy requirements of room temperature (RT) and superconducting (SC) magnet options of a new hadron therapy (HT) facility are compared. Special reference is made to the layouts ...considered for the proposed SEEIIST facility. Benchmarking with the RT CNAO HT centre in Pavia (Italy) was carried out. The energy comparison is centred on the different synchrotron solutions, assuming the same injector and lines in the designs. The beam current is 20 times higher than in present generation facilities: this allows efficient multi-energy extraction (MEE), which shortens the therapy treatment and is needed especially in the SC option, because of the slow magnet ramping time. Hence, power values of the facility in the traditional mode were converted into MEE ones, for a fair comparison between RT and SC magnets. Cryocoolers (c.c.) and a liquefier are also compared, for synchrotron refrigeration. This study shows that a RT facility in MEE mode requires the least average energy, followed by the SC synchrotron solution with a liquefier, while the most energy intensive solution is the SC one with c.c.
Measurements of transverse profiles using ionization profile monitors (IPMs) for high brightness beams are affected by the electromagnetic field of the beam. This interaction may cause a distortion ...of the measured profile shape despite strong external magnetic field applied to impose limits on the transverse movement of electrons. The mechanisms leading to this distortion are discussed in detail. The distortion itself is described by means of analytic calculations for simplified beam distributions and a full simulation model for realistic distributions. Simple relation for minimum magnetic field scaling with beam parameters for avoiding profile distortions is presented. Further, application of machine learning algorithms to the problem of reconstructing the actual beam profile from distorted measured profile is presented. The obtained results show good agreement for tests on simulation data. The performance of these algorithms indicate that they could be very useful for operations of IPMs on high brightness beams or IPMs with weak magnetic field.
Measurements of undistorted transverse profiles via Ionization Profile Monitors (IPMs) may pose a great challenge for high brightness or high energy beams due to interaction of ionized electrons or ...ions with the electromagnetic field of the beam. This contribution presents application of various machine learning algorithms to the problem of inferring the actual beam profile width from measured profiles that are distorted by beam space-charge interaction. (Generalized) linear regression, artificial neural network and support vector machine algorithms are trained with simulation data, obtained from the Virtual-IPM simulation tool, in order to learn the relation between distorted profiles and original beam dimension. The performance of different algorithms is assessed and the obtained results are very promising with simulation data.
Abstract
Recent years have seen an increased interest in the use of helium for radiation therapy of cancer. Helium ions can be more precisely delivered to the tumour than protons or carbon ions, ...presently the only beams licensed for treatment, with a biological effectiveness between the two. The accelerator required for helium is considerably smaller than a standard carbon ion synchrotron. To exploit the potential of helium therapy and of other emerging particle therapy techniques, in the framework of the Next Ion Medical Machine Study (NIMMS) at CERN, the design of a compact synchrotron optimised for acceleration of proton and helium beams has been investigated. The synchrotron is based on a new magnet design, profits from a novel injector linac, and can provide both slow and fast extraction for conventional and FLASH therapy. Production of mini-beams, and operation with multiple ions for imaging and treatment are also considered. This accelerator is intended to become the main element of a facility devoted to a parallel programme of cancer research and treatment with proton and helium beams, to both cure patients and contribute to the assessment of helium beams as a new tool to fight cancer.
As a result of the foreseen increase in the luminosity of the Large Hadron Collider, the discrimination between the collision products and possible magnet quench-provoking beam losses of the primary ...proton beams is becoming more critical for safe accelerator operation. We report the results of ongoing research efforts targeting the upgrading of the monitoring system by exploiting Beam Loss Monitor detectors based on semiconductors located as close as possible to the superconducting coils of the triplet magnets. In practice, this means that the detectors will have to be immersed in superfluid helium inside the cold mass and operate at 1.9K. Additionally, the monitoring system is expected to survive 20 years of LHC operation, resulting in an estimated radiation fluence of 1×1016 proton/cm2, which corresponds to a dose of about 2MGy. In this study, we monitored the signal degradation during the in situ irradiation when silicon and single-crystal diamond detectors were situated in the liquid/superfluid helium and the dependences of the collected charge on fluence and bias voltage were obtained. It is shown that diamond and silicon detectors can operate at 1.9K after 1×1016p/cm2 irradiation required for application as BLMs, while the rate of the signal degradation was larger in silicon detectors than in the diamond ones. For Si detectors this rate was controlled mainly by the operational mode, being larger at forward bias voltage.
•Silicon and diamond detectors are proposed for beam loss monitoring at LHC.•The first in situ radiation test of Si and diamond detectors at 1.9K is described.•Both diamond and silicon detectors survived after 1×1016p/cm2 irradiation at 1.9K.•The rate of Si detectors degradation depends on bias polarity and is larger at Vforw.•Sensitivity of Si detectors irradiated to 1×1016p/cm2 is independent on resistivity.
In the years 2009–2013 the Large Hadron Collider (LHC) has been operated with the top beam energies of 3.5 and 4 TeV per proton (from 2012) instead of the nominal 7 TeV. The currents in the ...superconducting magnets were reduced accordingly. To date only seventeen beam-induced quenches have occurred; eight of them during specially designed quench tests, the others during injection. There has not been a single beam-induced quench during normal collider operation with stored beam. The conditions, however, are expected to become much more challenging after the long LHC shutdown. The magnets will be operating at near nominal currents, and in the presence of high energy and high intensity beams with a stored energy of up to 362 MJ per beam. In this paper we summarize our efforts to understand the quench levels of LHC superconducting magnets. We describe beam-loss events and dedicated experiments with beam, as well as the simulation methods used to reproduce the observable signals. The simulated energy deposition in the coils is compared to the quench levels predicted by electrothermal models, thus allowing one to validate and improve the models which are used to set beam-dump thresholds on beam-loss monitors for run 2.
Monte Carlo shower simulations are essential for understanding and predicting the consequences of beam losses in high-energy proton and ion colliders. Shower simulations are routinely used at CERN ...for estimating the beam-induced energy deposition, radiation damage, and radioactivity in the Large Hadron Collider (LHC). Comparing these shower simulations against beam loss measurements is an important prerequisite for assessing the predictive ability of model calculations. This paper validates fluka simulation predictions of beam loss monitor (BLM) signals against BLM measurements from proton fills at 3.5 and 4 TeV andPb20882+ion fills at1.38ATeV. The paper addresses typical loss scenarios and loss mechanisms encountered in LHC operation, including proton collisions with dust particles liberated into the beams, halo impact on collimators in the betatron cleaning insertion, proton-proton collisions in the interaction points, and dispersive losses due to bound-free pair production in heavy ion collisions. Model predictions and measured signals generally match within a few tens of percent, although systematic differences were found to be as high as a factor of 3 for some regions and source terms.
A residual gas ionization profile monitor has been recently installed in the CERN proton synchrotron. We present the design for a novel and simplified field cage structure that suppresses the ...secondary electrons that are induced by the ionized ions. We discuss the field cage design and the beam size and emittance systematic error considering the non-uniformity of the fields, the space-charge effect of the beam, and the lattice parameter errors.