The Mu2e experiment at Fermilab aims to search for the SM forbidden μ−→e− conversion in Al muonic atoms. The signal signature consists of 104.96 MeV electrons, identified by a straw-tube tracker and ...a crystal calorimeter, made of two annular disks. In order to calibrate the calorimeter disks with minimum ionizing particles (MIP) before the installation, we have realized a Cosmic Ray Tagger (CRT) at Laboratori Nazionali di Frascati (LNF) of INFN. The CRT consists of two planes of eight 2.5×1.5×160 cm3 plastic scintillator (EJ-200) bars, coupled to SiPMs on both edges, so as to estimate longitudinal hit positions from time differences. 3D MIP tracking is achieved by reconstructing hit positions in the two planes, placed above and below the disks, and allows to calibrate the energy response, to align the time offsets, and to study the detector performances dependence along the crystals axis.
The Mu2e experiment (Bernstein et al., 0000) 1 at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw ...tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photomultipliers and fast front-end and digitization electronics. The front-end electronics consists of two discrete readout circuits (AMP-HV) for each crystal. These provide the amplification and shaping stage,linear regulation of the SiPM bias voltage and monitoring. The SiPM and front-end control electronics is implemented in a battery of mezzanine boards each equipped with an ARM processor that controls a group of 20 Amp-HV circuits, distributes the low voltage and the high-voltage reference values, sets and reads back the locally regulated voltages. The electronic is hosted in crates located on the external surface of calorimeter disks. The crates also host the waveform digitizer board (DIRAC) that performs digitization of the front end signals and transmit the digitized data to the Mu2e DAQ. Calorimeter electronic is hosted inside the cryostat and it must substain very high radiation and magnetic field so it was necessary to fully qualify it. The constraints on the calorimeter front-end and readout electronics, the design technological choices and the qualification tests will be reviewed.
The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in ...operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.
The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in ...operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. Here, in this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.
Performance of the LHCb muon system Alves, AA Jr; Anderlini, L; Anelli, M ...
Journal of instrumentation,
02/2013, Letnik:
7, Številka:
2
Journal Article
Recenzirano
Odprti dostop
The performance of the LHCb Muon system and its stability across the full 2010 data taking with LHC running at square root s = 7 TeV energy is studied. The optimization of the detector setting and ...the time calibration performed with the first collisions delivered by LHC is described. Particle rates, measured for the wide range of luminosities and beam operation conditions experienced during the run, are compared with the values expected from simulation. The space and time alignment of the detectors, chamber efficiency, time resolution and cluster size are evaluated. The detector performance is found to be as expected from specifications or better. Notably the overall efficiency is well above the design requirements.
The Calorimeter of the Mu2e experiment is a complicated detector made of crystal scintillators with dedicated read-out electronics per crystals. The compactness of the Front-End Units matrix, the ...complexity of the necessary services, and the limited space available after detector installation in the experimental hall make access, manipulation and maintenance of the Front-End Units very hard. This paper reports on the conceptual mechanical design of a robotic arm composed of a gantry structure for xyz positioning on the desired Front-End Unit and equipped with custom-designed grippers to perform the necessary maintenance operations. This includes the optimization of the Front-End Units cables routing.
Design and status of the Mu2e electromagnetic calorimeter Atanov, N.; Baranov, V.; Budagov, J. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
07/2016, Letnik:
824
Journal Article
Recenzirano
Odprti dostop
The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5×10−17 after three years of data taking. ...The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500ps at 100MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC׳s is also presented.
The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets. Calorimeters, ...as other detectors, must face this increasing performance demand. In a future TeV-scale Muon Collider, the beam-induced background (BIB) represents the main challenge in the design of the detectors and of the event reconstruction algorithms and can pose serious limitations to the physics performance. However, it is possible to reduce the BIB impact on the Muon Collider calorimeter by exploiting some of its characteristics and by ensuring high granularity, excellent timing, longitudinal segmentation and good energy resolution. The proposed R&D is an innovative semi-homogeneous electromagnetic calorimeter based on stackable modules of lead fluoride crystals (PbF
2
) readout by surface-mount UV-extended Silicon Photomultipliers (SiPMs): the Crilin calorimeter (CRystal calorImeter with Longitudinal INformation). The calorimeter should operate in a very harsh radiation environment, withstanding yearly a neutron flux of 10
14
n1MeV /cm
2
and a dose of 100 krad.
In this paper, the radiation tolerance measured in several irradiation campaigns and the timing performances evaluated during a test beam at CERN-H2 with 120-GeV electron are discussed. A description of the latest prototype Proto-1, that will be shortly tested, is also provided.
The Mu2e calorimeter: Quality assurance of production crystals and SiPMs Atanov, N.; Baranov, V.; Budagov, J. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
08/2019, Letnik:
936, Številka:
C
Journal Article
Recenzirano
Odprti dostop
The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been ...translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected times.