Carbon ion beams in the energy range of about 100-450 MeV/u offer excellent conditions for tumour therapy, in particular for the treatment of deep-seated radio-resistant tumours. Their depth-dose ...distribution is characterized by a low dose in the entrance channel, small lateral beam spread and an elevated biological effectiveness in the Bragg peak region. In comparison to protons the radiation field of heavier ions stopping in tissue is however more complex due to nuclear fragmentation reactions occurring along their stopping path. This results in an attenuation of the primary beam flux and a build-up of lower-Z fragments with longer ranges causing the characteristic dose tail beyond the Bragg peak. In the present work the characteristics of secondary charged particles at various depths of water were investigated experimentally using (12)C ion beams of 200 and 400 MeV/u delivered by the heavy-ion synchrotron SIS-18 at GSI Darmstadt. The nuclear charge Zf of secondary fragments was identified by combining energy loss and time-of-flight (TOF) measurements. Energy spectra and yields were recorded at lab angles of 0° - 10° and at seven different water depths corresponding to the entrance channel, the Bragg peak region and the tail of the Bragg curve.
This investigation focused on the characterization of the lateral dose fall-off following the irradiation of the target with photons, protons and carbon ions. A water phantom was irradiated with a ...rectangular field using photons, passively delivered protons as well as scanned protons and carbon ions. The lateral dose profile in the depth of the maximum dose was measured using an ion chamber, a diamond detector and thermoluminescence detectors TLD-600 and TLD-700. The yield of thermal neutrons was estimated for all radiation types while their complete spectrum was measured with bubble detectors during the irradiation with photons. The peripheral dose delivered by photons is significantly higher compared to both protons and carbon ions and exceeds the latter by up to two orders of magnitude at distances greater than 50 mm from the field. The comparison of passive and active delivery techniques for protons shows that, for the chosen rectangular target shape, the former has a sharper penumbra whereas the latter has a lower dose in the far-out-of-field region. When comparing scanning treatments, carbon ions present a sharper dose fall-off than protons close to the target but increasing peripheral dose with increasing incident energy. For photon irradiation, the contribution to the out-of-field dose of photoneutrons appears to be of the same order of magnitude as the scattered primary beam. Charged particles show a clear supremacy over x-rays in achieving a higher dose conformality around the target and in sparing the healthy tissue from unnecessary radiation exposure. The out-of-field dose for x-rays increases with increasing beam energy because of the production of biologically harmful neutrons.
Prompt-gamma emission detection is a promising technique for hadrontherapy monitoring purposes. In this regard, obtaining prompt-gamma yields that can be used to develop monitoring systems based on ...this principle is of utmost importance since any camera design must cope with the available signal. Herein, a comprehensive study of the data from ten single-slit experiments is presented, five consisting in the irradiation of either PMMA or water targets with lower and higher energy carbon ions, and another five experiments using PMMA targets and proton beams. Analysis techniques such as background subtraction methods, geometrical normalization, and systematic uncertainty estimation were applied to the data in order to obtain absolute prompt-gamma yields in units of prompt-gamma counts per incident ion, unit of field of view, and unit of solid angle. At the entrance of a PMMA target, where the contribution of secondary nuclear reactions is negligible, prompt-gamma counts per incident ion, per millimetre and per steradian equal to (124 ± 0.7stat ± 30sys) × 10−6 for 95 MeV u−1 carbon ions, (79 ± 2stat ± 23sys) × 10−6 for 310 MeV u−1 carbon ions, and (16 ± 0.07stat ± 1sys) × 10−6 for 160 MeV protons were found for prompt gammas with energies higher than 1 MeV. This shows a factor 5 between the yields of two different ions species with the same range in water (160 MeV protons and 310 MeV u−1 carbon ions). The target composition was also found to influence the prompt-gamma yield since, for 300/310 MeV u−1 carbon ions, a 42% greater yield ((112 ± 1stat ± 22sys) × 10−6 counts ion−1 mm−1 sr−1) was obtained with a water target compared to a PMMA one.
We describe a novel code system, TRiP, dedicated to the planning of radiotherapy with energetic ions, in particular 12C. The software is designed to cooperate with three-dimensional active dose ...shaping devices like the GSI raster scan system. This unique beam delivery system allows us to select any combination from a list of 253 individual beam energies, 7 different beam spot sizes and 15 intensity levels. The software includes a beam model adapted to and verified for carbon ions. Inverse planning techniques are implemented in order to obtain a uniform target dose distribution from clinical input data, i.e. CT images and patient contours. This implies the automatic generation of intensity modulated fields of heavy ions with as many as 40000 raster points, where each point corresponds to a specific beam position, energy and particle fluence. This set of data is directly passed to the beam delivery and control system. The treatment planning code has been in clinical use since the start of the GSI pilot project in December 1997. Forty-eight patients have been successfully planned and treated.
Short- and long-term side effects following the treatment of cancer with radiation are strongly related to the amount of dose deposited to the healthy tissue surrounding the tumor. The ...characterization of the radiation field outside the planned target volume is the first step for estimating health risks, such as developing a secondary radioinduced malignancy. In ion and high-energy photon treatments, the major contribution to the dose deposited in the far-out-of-field region is given by neutrons, which are produced by nuclear interaction of the primary radiation with the beam line components and the patient's body. Measurements of the secondary neutron field and its contribution to the absorbed dose and equivalent dose for different radiotherapy technologies are presented in this work. An anthropomorphic RANDO phantom was irradiated with a treatment plan designed for a simulated 5 × 2 × 5 cm3 cancer volume located in the center of the head. The experiment was repeated with 25 MV IMRT (intensity modulated radiation therapy) photons and charged particles (protons and carbon ions) delivered with both passive modulation and spot scanning in different facilities. The measurements were performed with active (silicon-scintillation) and passive (bubble, thermoluminescence 6LiF:Mg, Ti (TLD-600) and 7LiF:Mg, Ti (TLD-700)) detectors to investigate the production of neutral particles both inside and outside the phantom. These techniques provided the whole energy spectrum (E 20 MeV) and corresponding absorbed dose and dose equivalent of photo neutrons produced by x-rays, the fluence of thermal neutrons for all irradiation types and the absorbed dose deposited by neutrons with 0.8 < E < 10 MeV during the treatment with scanned carbon ions. The highest yield of thermal neutrons is observed for photons and, among ions, for passively modulated beams. For the treatment with high-energy x-rays, the contribution of secondary neutrons to the dose equivalent is of the same order of magnitude as the primary radiation. In carbon therapy delivered with raster scanning, the absorbed dose deposited by neutrons in the energy region between 0.8 and 10 MeV is almost two orders of magnitude lower than charged fragments. We conclude that, within the energy range explored in this experimental work, the out-of-field dose from secondary neutrons is lowest for ions delivered by scanning, followed by passive modulation, and finally by high-energy IMRT photons.
For real-time monitoring of the longitudinal position of the Bragg-peak during an ion therapy treatment, a novel non-invasive technique has been recently proposed that exploits the detection of ...prompt γ-rays issued from nuclear fragmentation. Two series of experiments have been performed at the GANIL and GSI facilities with 95 and 305 MeV/u ¹²C⁶⁺ ion beams stopped in PMMA and water phantoms. In both experiments, a clear correlation was obtained between the carbon ion range and the prompt photon profile. Additionally, an extensive study has been performed to investigate whether a prompt neutron component may be correlated with the carbon ion range. No such correlation was found. The present paper demonstrates that a collimated set-up can be used to detect single photons by means of time-of-flight measurements, at those high energies typical for ion therapy. Moreover, the applicability of the technique both at cyclotron and at synchrotron facilities is shown. It is concluded that the detected photon count rates provide sufficiently high statistics to allow real-time control of the longitudinal position of the Bragg-peak under clinical conditions.
To comprehend emotional prosodic cues in speech is a critical function of human social life. However, it is common in everyday communication that conflicting information in emotional prosody and ...semantic content co-occur. Here, we sought to specify brain regions involved in conflict monitoring of these interfering communication channels. By means of functional magnetic resonance imaging, we obtained signal increases in the right dorsal anterior cingulate cortex and right superior temporal gyrus (STG) and superior temporal sulcus when participants listened to incongruous compared with congruous sentences. Moreover, valence-specific effects were found in the left inferior frontal gyrus and left STG for happily intoned sentences expressing a negative content. The left caudate nucleus along with the thalamus was active when angrily intoned sentences were coupled with positive semantic content. Our results suggest a brain network that monitors conflict in emotional prosody and emotional semantic content comprising of medial prefrontal areas that have previously been associated with cognitive conflict processing. Furthermore, our study extends the knowledge of these processes by suggesting valence-specific differences of emotional conflict processing.
Monte Carlo simulations based on the Geant4 toolkit (version 9.1) were performed to study the emission of secondary prompt-gamma rays produced by nuclear reactions during carbon ion-beam therapy. ...These simulations were performed along with an experimental program and instrumentation developments which aim at designing a prompt-gamma ray device for real-time control of hadrontherapy. The objective of the present study is twofold: firstly, to present the features of the prompt-gamma radiation in the case of carbon ion irradiation; secondly, to simulate the experimental setup and to compare measured and simulated counting rates corresponding to four different experiments. For each experiment, we found that simulations overestimate prompt-gamma ray detection yields by a factor of 12. Uncertainties in fragmentation cross sections and binary cascade model cannot explain such discrepancies. The so-called "photon evaporation" model is therefore questionable and its modification is currently in progress.
The goal of external-beam radiotherapy is to provide precise dose localisation in the treatment volume of the target with minimal damage to the surrounding normal tissue. Ion beams, such as protons ...and carbon ions, provide excellent dose distributions due primarily to their finite range, allowing a significant reduction of undesired exposure of normal tissue. Careful treatment planning is required for the given type and localisation of the tumour to be treated in order to maximise treatment efficiency and minimise the dose to normal tissue. Radiation exposure in out-of-field volumes arises from secondary neutrons and photons, particle fragments, and photons from activated materials. These unavoidable doses should be considered from the standpoint of radiological protection of the patient. Radiological protection of medical staff at ion beam radiotherapy facilities requires special attention. Appropriate management and control are required for the therapeutic equipment and the air in the treatment room that can be activated by the particle beam and its secondaries. Radiological protection and safety management should always conform with regulatory requirements. The current regulations for occupational exposures in photon radiotherapy are applicable to ion beam radiotherapy with protons or carbon ions. However, ion beam radiotherapy requires a more complex treatment system than conventional radiotherapy, and appropriate training of staff and suitable quality assurance programmes are recommended to avoid possible accidental exposure of patients, to minimise unnecessary doses to normal tissue, and to minimise radiation exposure of staff.
One of the major advantages of proton or ion beams, applied in cancer treatment, is their excellent depth-dose profile exhibiting a low dose in the entrance channel and a distinct dose maximum (Bragg ...peak) near the end of range in tissue. In the region of the Bragg peak, where the protons or ions are almost stopped, experimental studies with low-energy particle beams and thin biological samples may contribute valuable information on the biological effectiveness in the stopping region. Such experiments, however, require beam optimization and special dosimetry techniques for determining the absolute dose and dose homogeneity for very thin biological samples. At the National Centre of Accelerators in Seville, one of the beam lines at the 3 MV Tandem Accelerator was equipped with a scattering device, a special parallel-plate ionization chamber with very thin electrode foils and target holders for cell cultures. In this work, we present the calibration in absolute dose of EBT3 films Gafchromic radiotherapy films, http://www.ashland.com/products/gafchromic-radiotherapy-films for proton energies in the region of the Bragg peak, where the linear energy transfer increases and becomes more significant for radiobiology studies, as well as the response of the EBT3 films for different proton energy values. To irradiate the films in the Bragg peak region, the energy of the beam was degraded passively, by interposing Mylar foils of variable thickness to place the Bragg peak inside the active layer of the film. The results obtained for the beam degraded in Mylar foils are compared with the dose calculated by means of the measurement of the beam fluence with an ionization chamber and the energy loss predicted by srim2008 code.