Abstract Gastroesophageal reflux disease (GERD) presents a general health problem with a variety of symptoms and an impairment of life quality. Conservative therapies do not offer sufficient symptom ...relief in up to 30% of patients. Patients who suffer from ineffective esophageal motility (IEM) and also GERD may exhibit symptoms ranging from mild to severe. In cases where surgical intervention becomes necessary for this diverse group of patients, it is important to consider the potential occurrence of postoperative dysphagia. RefluxStop is a new alternative anti-reflux surgery potentially reducing postoperative dysphagia rates. In this bicentric tertiary hospital observational study consecutive patients diagnosed with PPI refractory GERD and IEM that received RefluxStop implantation were included. A first safety and efficacy evaluation including clinical examination and GERD-HRQL questionnaire was conducted. 40 patients (25 male and 15 female) were included. 31 patients (77.5%) were on PPI at time of surgery, with mean acid exposure time of 8.14% ± 2.53. The median hospital stay was 3 days. Postoperative QoL improved significantly measured by GERD HRQL total score from 32.83 ± 5.08 to 6.6 ± 3.71 (p < 0.001). A 84% reduction of PPI usage (p < 0.001) was noted. 36 patients (90%) showed gone or improved symptoms and were satisfied at first follow-up. Two severe adverse events need mentioning: one postoperative slipping of the RefluxStop with need of immediate revisional operation on the first postoperative day (Clavien–Dindo Score 3b) and one device migration with no necessary further intervention. RefluxStop device implantation is safe and efficient in the short term follow up in patients with GERD and IEM. Further studies and longer follow-up are necessary to prove long-lasting positive effects.
Minimally invasive oesophagectomy (MIO) for oesophageal cancer may reduce surgical complications compared with open oesophagectomy. MIO is, however, technically challenging and may impair optimal ...oncological resection. The aim of the present study was to assess if MIO for cancer is beneficial.
A systematic literature search in MEDLINE, Web of Science and CENTRAL was performed and randomized controlled trials (RCTs) comparing MIO with open oesophagectomy were included in a meta-analysis. Survival was analysed using individual patient data. Random-effects model was used for pooled estimates of perioperative effects.
Among 3219 articles, six RCTs were identified including 822 patients. Three-year overall survival (56 (95 per cent c.i. 49 to 62) per cent for MIO versus 52 (95 per cent c.i. 44 to 60) per cent for open; P = 0.54) and disease-free survival (54 (95 per cent c.i. 47 to 61) per cent versus 50 (95 per cent c.i. 42 to 58) per cent; P = 0.38) were comparable. Overall complication rate was lower for MIO (odds ratio 0.33 (95 per cent c.i. 0.20 to 0.53); P < 0.010) mainly due to fewer pulmonary complications (OR 0.44 (95 per cent c.i. 0.27 to 0.72); P < 0.010), including pneumonia (OR 0.41 (95 per cent c.i. 0.22 to 0.77); P < 0.010).
MIO for cancer is associated with a lower risk of postoperative complications compared with open resection. Overall and disease-free survival are comparable for the two techniques.
Oesophagectomy for cancer is associated with a high risk of complications. A minimally invasive approach might be less traumatic, leading to fewer complications and may also improve oncological outcome. A meta-analysis of randomized controlled trials comparing minimally invasive to open oesophagectomy was performed. The analysis showed that the minimally invasive approach led to fewer postoperative complications, in particular, fewer pulmonary complications. Survival after surgery was comparable for the two techniques.
Abstract Background Nutritional status and body composition parameters such as sarcopenia are important risk factors for impaired outcome in patients with esophageal cancer. This study was conducted ...to evaluate the effect of sarcopenia on long-term outcome after esophageal resection following neoadjuvant treatment. Methods Skeletal muscle index (SMI) and body composition parameters were measured in patients receiving neoadjuvant treatment for locally advanced esophageal cancer. Endpoints included relapse-free survival (RFS) and overall survival (OS). Results The study included 130 patients. Sarcopenia was found in 80 patients (61.5%). Patients with squamous-cell cancer (SCC) showed a decreased median SMI of 48 (range 28.4–60.8) cm/m2 compared with that of patients with adenocarcinoma (AC) of 52 (range 34.4–74.2) cm/m2 , P < 0.001. The presence of sarcopenia had a significant impact on patient outcome: HR 1.69 (1.04–2.75), P = 0.036. Median OS was 20.5 (7.36–33.64) versus 52.1 (13.55–90.65) months in sarcopenic and non-sarcopenic patients, respectively. Sarcopenia was identified as an independent risk factor: HR 1.72 (1.049–2.83), P = 0.032. Conclusion Our data provide evidence that sarcopenia impacts long-term outcome after esophageal resection in patients who have undergone neoadjuvant therapy. Assessment of the body composition parameter can be a reasonable part of patient selection and may influence treatment methods.
The reactor antineutrino anomaly might be explained by the oscillation of reactor antineutrinos toward a sterile neutrino of eV mass. In order to explore this hypothesis, the STEREO experiment ...measures the antineutrino energy spectrum in six different detector cells covering baselines between 9 and 11 m from the compact core of the ILL research reactor. In this Letter, results from 66 days of reactor turned on and 138 days of reactor turned off are reported. A novel method to extract the antineutrino rates has been developed based on the distribution of the pulse shape discrimination parameter. The test of a new oscillation toward a sterile neutrino is performed by comparing ratios of cells, independent of absolute normalization and of the prediction of the reactor spectrum. The results are found to be compatible with the null oscillation hypothesis and the best fit of the reactor antineutrino anomaly is excluded at 97.5% C.L.
There is rising interest in organic scintillators with low scattering length for future neutrino detectors. Therefore, a new scintillator system was developed based on admixtures of paraffin wax in ...linear alkyl benzene. The transparency and viscosity of this gel-like material can be tuned by temperature adjustment. Whereas it is a colorless transparent liquid at temperatures around 40ˆC, it has a milky wax structure below 20ˆC. The production and properties of such a scintillator as well as its advantages compared to transparent liquids are described.
Gastric cancer is one of the most commonly diagnosed and the second leading cause of cancer death worldwide. Surgery combined with multimodal therapy remains the only curative therapy. However, local ...relapse or distant metastases occur in more than 50% of radically resected patients. Due to molecular therapies, targeting HER2 and angiogenesis, major advances in the treatment of gastric cancer could be achieved. Nevertheless, development of resistance to monoclonal antibodies, such as trastuzumab, is arising. Currently a number of promising new therapeutic are under investigation, combining chemotherapy with newly developed agents to overcome cancer resistance. In this review we report current clinical applications of targeted therapies and overview ongoing trials, investigating the use of monoclonal antibodies in (HER2 positive) gastric cancer.
The electron antineutrino spectrum in the STEREO reactor experiment (ILL Grenoble) is measured via the inverse beta decay signals in an organic liquid scintillator. The six target cells of the STEREO ...detector are filled with about 1800 litres of Gd-loaded liquid scintillator optimised for the requirements of the experiment. These target cells are surrounded by similar cells containing liquid scintillator without the Gd-loading. The development and characteristics of these scintillators are reported. In particular, the transparency, light production and pulse shape discrimination capabilities of the organic liquids are discussed.
Background: Vascular endothelial growth factor-C (VEGF-C) is the main inducer of lymphangiogenesis. VEGF-C overexpression is associated with lymphovascular tumor cell invasion, an increased rate of ...lymph node metastasis and adverse prognosis in various human cancers. However, little is known about the upstream inducers of VEGF-C expression. Recent studies have shown that human epidermal growth factor receptor 2 (HER2/neu) overexpression is associated with high VEGF-C levels in human breast cancer cells. In addition to blocking of HER2/neu, tyrosine kinase significantly decreased VEGF-C expression in vitro.
Patients and methods: VEGF-C expression, lymphatic microvessel density (LMVD), lymphovascular invasion (LVI) and HER2/neu expression were evaluated with immunohistochemical/FISH methods in a collective of 150 lymph node-positive human breast cancers with long-term follow-up.
Results: Cases with 3+ HER2/neu protein expression showed a significantly stronger VEGF-C expression than all others cases (P=0.006). In addition, we found a significant correlation between VEGF-C expression and LMVD (P=0.012) and a strong positive association between LMVD and LVI (P<0.001).
Conclusion: Our data provide evidence for a clinically relevant association between HER2/neu and VEGF-C expression in human breast cancer. Inhibiting HER2/neu may reduce tumor progression by blocking VEGF-C-mediated tumor cell proliferation and lymphogenic metastasis.
SUMMARY
The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent ...migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, UILJ, UKNU, UL, UM, UPUK
Anomalies in past neutrino measurements have led to the discovery that these particles have non-zero mass and oscillate between their three flavours when they propagate. In the 2010s, similar ...anomalies observed in the antineutrino spectra emitted by nuclear reactors have triggered the hypothesis of the existence of a supplementary neutrino state that would be sterile, that is, not interacting by means of the weak interaction1. The STEREO experiment2-6 was designed to investigate this conjecture, which would potentially extend the standard model of particle physics. Here we present an analysis of the full set of data generated by STEREO, confirming observed anomalies while rejecting the hypothesis of a light sterile neutrino. Installed at the Institut Laue-Langevin (ILL) research reactor, STEREO accurately measures the antineutrino energy spectrum associated to the fission of 235U. The segmentation of the detector and its very short distance to the compact core are crucial properties of STEREO for our analysis. The measured antineutrino energy spectrum suggests that anomalies originate from biases in the nuclear experimental data used for the predictions7,8. Our result supports the neutrino content of the standard model and establishes a new reference for the 235U antineutrino energy spectrum. We anticipate that this result will allow progress towards finer tests of the fundamental properties of neutrinos but also to benchmark models and nuclear data of interest for reactor physics9,10 and for observations of astrophysical or geoneutrinos11,12.