Digital health interventions (DHIs) are a central focus of health care transformation efforts, yet their uptake in practice continues to fall short of their potential. In order to achieve their ...desired outcomes and impact, DHIs need to reach their target population and need to be used. Many factors can rapidly intersect between this dynamic of users and interventions. The application of theories, models, and frameworks (TMFs) can facilitate the systematic understanding and explanation of the complex interactions between users, practices, technology, and health system factors that underpin research questions. There remains a gap in our understanding of how TMFs have been applied to guide the evaluation of DHIs with real-world health system operations.
This study aims to map TMFs used in studies to guide the evaluation of DHIs. The objectives are to (1) describe the TMFs and the constructs they target, (2) identify how TMFs have been prospectively used (ie, their roles) in primary studies to evaluate DHIs, and (3) to reflect on the relevance and utility of our findings for knowledge users.
This scoping review was conducted in partnership with knowledge users using an integrated knowledge translation approach. We included papers (eg, reports; empirical quantitative, qualitative, and mixed methods studies; conference proceedings; and dissertations) if primary insights resulting from the application of TMFs were presented. Any type of DHI was eligible. Papers published from 2000 and onward were mainly identified from the following databases: MEDLINE (Ovid), CINAHL Complete (EBSCOhost), PsycINFO (Ovid), EBM Reviews (Ovid), and Embase (Ovid).
A total of 156 studies published between 2000 and 2022 were included. A total of 68 distinct TMFs were identified across 85 individual studies. In more than half (85/156, 55%) of the included studies, 1 of following 6 prevailing TMFs were reported: Consolidated Framework for Implementation Research (n=39); the Reach, Effectiveness, Adoption, Implementation, and Maintenance Framework (n=17); the Technology of Acceptance Model (n=16); the Unified Theory on Acceptance and Use of Technology (n=12); the Diffusion of Innovation Theory (n=10); and Normalization Process Theory (n=9). The most common intended roles of the 6 TMFs were to inform data collection (n=86), to inform data analysis (n=69), and to identify key constructs that may serve as barriers and facilitators (n=52).
As TMFs are most often reported to be applied to support data collection and analysis, researchers should consider more clearly synthesizing key insights as practical use cases to both increase the relevance and digestibility of their findings. There is also a need to adapt or develop guidelines for better reporting DHIs and the use of TMFs to guide evaluation. Hence, it would contribute to ensuring ongoing technology transformation efforts are evidence and theory informed rather than anecdotally driven.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, UILJ, UKNU, UL, UM, UPUK
Mobile health (mHealth) interventions are increasingly being designed to facilitate health-related behavior change. Integrating insights from behavioral science and design science can help support ...the development of more effective mHealth interventions. Behavioral Design (BD) and Design Thinking (DT) have emerged as best practice approaches in their respective fields. Until now, little work has been done to examine how BD and DT can be integrated throughout the mHealth design process.
The aim of this scoping review was to map the evidence on how insights from BD and DT can be integrated to guide the design of mHealth interventions. The following questions were addressed: (1) what are the main characteristics of studies that integrate BD and DT during the mHealth design process? (2) what theories, models, and frameworks do design teams use during the mHealth design process? (3) what methods do design teams use to integrate BD and DT during the mHealth design process? and (4) what are key design challenges, implementation considerations, and future directions for integrating BD and DT during mHealth design?
This review followed the Joanna Briggs Institute reviewer manual and PRISMA-ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews) checklist. Studies were identified from MEDLINE, PsycINFO, Embase, CINAHL, and JMIR by using search terms related to mHealth, BD, and DT. Included studies had to clearly describe their mHealth design process and how behavior change theories, models, frameworks, or techniques were incorporated. Two independent reviewers screened the studies for inclusion and completed the data extraction. A descriptive analysis was conducted.
A total of 75 papers met the inclusion criteria. All studies were published between 2012 and 2021. Studies integrated BD and DT in notable ways, which can be referred to as "Behavioral Design Thinking." Five steps were followed in Behavioral Design Thinking: (1) empathize with users and their behavior change needs, (2) define user and behavior change requirements, (3) ideate user-centered features and behavior change content, (4) prototype a user-centered solution that supports behavior change, and (5) test the solution against users' needs and for its behavior change potential. The key challenges experienced during mHealth design included meaningfully engaging patient and public partners in the design process, translating evidence-based behavior change techniques into actual mHealth features, and planning for how to integrate the mHealth intervention into existing clinical systems.
Best practices from BD and DT can be integrated throughout the mHealth design process to ensure that mHealth interventions are purposefully developed to effectively engage users. Although this scoping review clarified how insights from BD and DT can be integrated during mHealth design, future research is needed to identify the most effective design approaches.
Digital health interventions (DHIs) are defined as health services delivered electronically through formal or informal care. DHIs can range from electronic medical records used by providers to mobile ...health apps used by consumers. DHIs involve complex interactions between user, technology and the healthcare team, posing challenges for implementation and evaluation. Theoretical or interpretive frameworks are crucial in providing researchers guidance and clarity on implementation or evaluation approaches; however, there is a lack of standardisation on which frameworks to use in which contexts. Our goal is to conduct a scoping review to identify frameworks to guide the implementation or evaluation of DHIs.
A scoping review will be conducted using methods outlined by the Joanna Briggs Institute reviewers' manual and will conform to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews. Studies will be included if they report on frameworks (ie, theoretical, interpretive, developmental) that are used to guide either implementation or evaluation of DHIs. Electronic databases, including MEDLINE, EMBASE, CINAHL and PsychINFO will be searched in addition to grey literature and reference lists of included studies. Citations and full text articles will be screened independently in Covidence after a reliability check among reviewers. We will use qualitative description to summarise findings and focus on how research objectives and type of DHIs are aligned with the frameworks used.
We engaged an advisory panel of digital health knowledge users to provide input at strategic stages of the scoping review to enhance the relevance of findings and inform dissemination activities. Specifically, they will provide feedback on the eligibility criteria, data abstraction elements, interpretation of findings and assist in developing key messages for dissemination. This study does not require ethical review. Findings from review will support decision making when selecting appropriate frameworks to guide the implementation or evaluation of DHIs.
Abstract Background During hand and finger motions, friction between flexor digitorum superficialis tendon and the median nerve is thought to play a role in the development of cumulative trauma ...disorders. This study investigated three methods to determine excursions of the flexor digitorum superficialis tendon and median nerve using several motions. Methods Twenty-five participants (mean age 37.2 years SD 13.4) were classified as healthy (n = 16), self-reported distal upper extremity cumulative trauma disorders (6), or wheelchair users (3). Static carpal tunnel measurements were taken and displacements of the index flexor digitorum superficialis tendon and median nerve were determined via the velocity time integral and post hoc integration of the Doppler ultrasound waveform using a 12–5 MHz linear array transducer, as well as using predictive equations. Findings Median nerves in symptomatic wrists were larger than healthy wrists by 4.2 mm2 (left) and 4.1 mm2 (right) proximally to less than 1.4 mm2 distally. In healthy wrists, left–right tendon excursion differences ranged from 0.7 mm to 4.3 mm depending on the motion while left to right differences in symptomatic wrists ranged over 22.2 mm. Ultrasound measures of tendon excursion overestimated those determined using predictive equations and were poorly correlated. The ratio of median nerve excursion to tendon excursion was lower in finger only motions compared to wrist motions with or without finger motion. Interpretation Spectral Doppler ultrasound imaging provided insights into tendon excursion that was not apparent with mathematical modeling. The difference in excursion between finger motions and wrist motions could be beneficial in therapeutic techniques.
Objectives
The purpose of this study was to demonstrate an increase in the detection rate of fetal cardiac defects using 2 cine loop sweeps.
Methods
Image reviewers examined a series of 93 cases ...randomly sorted, including 79 studies with normal findings and 14 studies with abnormal findings. All of the images were assessed by 5 standard criteria. Cases were classified as normal, abnormal, or indeterminate. Reviewers using the conventional approach reviewed 3 still images: the 4‐chamber, left ventricular outflow tract, and right ventricular outflow tract views. Reviewers using the cine loop sweeps viewed 2 grayscale sweeps through the fetal heart in real time. The image sequences were reviewed independently by 2 experts, 3 nonexperts, and 2 sonographers blinded to each others' results.
Results
The cine loop sweeps had an increased detection rate of 38% for the nonexperts and 36% for the experts compared with the conventional approach. The cine loop sweeps allowed identification of all cardiac defects by at least 2 of the 7 reviewers; the percentage of cases with false‐positive findings was 3.9%. With the conventional approach, 2 defects went undetected by all reviewers, and 4 defects were found by only 1 reviewer; the percentage of cases with false‐positive findings was 5.4%.
Conclusions
The use of cine loop sweeps has the potential to increase the detection of fetal cardiac defects without increasing the rate of false‐positive findings or increasing the interpretation and decision‐making times.
Wearable continuous monitoring biosensor technologies have the potential to transform postoperative care with early detection of impending clinical deterioration.
Our aim was to validate the accuracy ...of Cloud DX Vitaliti continuous vital signs monitor (CVSM) continuous noninvasive blood pressure (cNIBP) measurements in postsurgical patients. A secondary aim was to examine user acceptance of the Vitaliti CVSM with respect to comfort, ease of application, sustainability of positioning, and aesthetics.
Included participants were ≥18 years old and recovering from surgery in a cardiac intensive care unit (ICU). We targeted a maximum recruitment of 80 participants for verification and acceptance testing. We also oversampled to minimize the effect of unforeseen interruptions and other challenges to the study. Validation procedures were according to the International Standards Organization (ISO) 81060-2:2018 standards for wearable, cuffless blood pressure (BP) measuring devices. Baseline BP was determined from the gold-standard ICU arterial catheter. The Vitaliti CVSM was calibrated against the reference arterial catheter. In static (seated in bed) and supine positions, 3 cNIBP measurements, each 30 seconds, were taken for each patient with the Vitaliti CVSM and an invasive arterial catheter. At the conclusion of each test session, captured cNIBP measurements were extracted using MediCollector BEDSIDE data extraction software, and Vitaliti CVSM measurements were extracted to a secure laptop through a cable connection. The errors of these determinations were calculated. Participants were interviewed about device acceptability.
The validation analysis included data for 20 patients. The average times from calibration to first measurement in the static position and to first measurement in the supine position were 133.85 seconds (2 minutes 14 seconds) and 535.15 seconds (8 minutes 55 seconds), respectively. The overall mean errors of determination for the static position were -0.621 (SD 4.640) mm Hg for systolic blood pressure (SBP) and 0.457 (SD 1.675) mm Hg for diastolic blood pressure (DBP). Errors of determination were slightly higher for the supine position, at 2.722 (SD 5.207) mm Hg for SBP and 2.650 (SD 3.221) mm Hg for DBP. The majority rated the Vitaliti CVSM as comfortable. This study was limited to evaluation of the device during a very short validation period after calibration (ie, that commenced within 2 minutes after calibration and lasted for a short duration of time).
We found that the Cloud DX's Vitaliti CVSM demonstrated cNIBP measurement in compliance with ISO 81060-2:2018 standards in the context of evaluation that commenced within 2 minutes of device calibration; this device was also well-received by patients in a postsurgical ICU setting. Future studies will examine the accuracy of the Vitaliti CVSM in ambulatory contexts, with attention to assessment over a longer duration and the impact of excessive patient motion on data artifacts and signal quality.
ClinicalTrials.gov NCT03493867; https://clinicaltrials.gov/ct2/show/NCT03493867.
Performing Ethnomusicologyis the first book to deal exclusively with creating, teaching, and contextualizing academic world music performing ensembles. Considering the formidable theoretical, ...ethical, and practical issues that confront ethnomusicologists who direct such ensembles, the sixteen essays in this volume discuss problems of public performance and the pragmatics of pedagogy and learning processes. Their perspectives, drawing upon expertise in Caribbean steelband, Indian, Balinese, Javanese, Philippine, Mexican, Central and West African, Japanese, Chinese, Middle Eastern, and Jewish klezmer ensembles, provide a uniquely informed and many-faceted view of this complicated and rapidly changing landscape. The authors examine the creative and pedagogical negotiations involved in intergenerational and intercultural transmission and explore topics such as reflexivity, representation, hegemony, and aesthetically determined interaction.Performing Ethnomusicologyaffords sophisticated insights into the structuring of ethnomusicologists' careers and methodologies. This book offers an unprecedented rich history and contemporary examination of academic world music performance in the West, especially in the United States. "Performing Ethnomusicologyis an important book not only within the field of ethnomusicology itself, but for scholars in all disciplines engaged in aspects of performance-historical musicology, anthropology, folklore, and cultural studies. The individual articles offer a provocative and disparate array of threads and themes, which Solís skillfully weaves together in his introductory essay. A book of great importance and long overdue."-R. Anderson Sutton, author ofCalling Back the SpiritContributors:Gage Averill, Kelly Gross, David Harnish, Mantle Hood, David W. Hughes, Michelle Kisliuk, David Locke, Scott Marcus, Hankus Netsky, Ali Jihad Racy, Anne K. Rasmussen, Ted Solís, Hardja Susilo, Sumarsam, Ricardo D. Trimillos, Roger Vetter, J. Lawrence Witzleben
Cardiac and major vascular surgeries are common surgical procedures associated with high rates of postsurgical complications and related hospital readmission. In-hospital remote automated monitoring ...(RAM) and virtual hospital-to-home patient care systems have major potential to improve patient outcomes following cardiac and major vascular surgery. However, the science of deploying and evaluating these systems is complex and subject to risk of implementation failure.
As a precursor to a randomized controlled trial (RCT), this user testing study aimed to examine user performance and acceptance of a RAM and virtual hospital-to-home care intervention, using Philip's Guardian and Electronic Transition to Ambulatory Care (eTrAC) technologies, respectively.
Nurses and patients participated in systems training and individual case-based user testing at two participating sites in Canada and the United Kingdom. Participants were video recorded and asked to think aloud while completing required user tasks and while being rated on user performance. Feedback was also solicited about the user experience, including user satisfaction and acceptance, through use of the Net Promoter Scale (NPS) survey and debrief interviews.
A total of 37 participants (26 nurses and 11 patients) completed user testing. The majority of nurse and patient participants were able to complete most required tasks independently, demonstrating comprehension and retention of required Guardian and eTrAC system workflows. Tasks which required additional prompting by the facilitator, for some, were related to the use of system features that enable continuous transmission of patient vital signs (eg, pairing wireless sensors to the patient) and assigning remote patient monitoring protocols. NPS scores by user group (nurses using Guardian: mean 8.8, SD 0.89; nurses using eTrAC: mean 7.7, SD 1.4; patients using eTrAC: mean 9.2, SD 0.75), overall NPS scores, and participant debrief interviews indicated nurse and patient satisfaction and acceptance of the Guardian and eTrAC systems. Both user groups stressed the need for additional opportunities to practice in order to become comfortable and proficient in the use of these systems.
User testing indicated a high degree of user acceptance of Philips' Guardian and eTrAC systems among nurses and patients. Key insights were provided that informed refinement of clinical workflow training and systems implementation. These results were used to optimize workflows before the launch of an international RCT of in-hospital RAM and virtual hospital-to-home care for patients undergoing cardiac and major vascular surgery.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, UILJ, UKNU, UL, UM, UPUK
The pursuit of more efficient patient-friendly health systems and reductions in tertiary health services use has seen enormous growth in the application and study of remote patient monitoring systems ...for cardiovascular patient care. While there are many consumer-grade products available to monitor patient wellness, the regulation of these technologies varies considerably, with most products having little to no evaluation data. As the science and practice of virtual care continues to evolve, clinicians and researchers can benefit from an understanding of more comprehensive solutions capable of monitoring multiple biophysical parameters (eg, oxygen saturation, heart rate) continuously and simultaneously. These devices, herein referred to as continuous multiparameter remote automated monitoring (CM-RAM) devices, have the potential to revolutionise virtual patient care. Through seamless integration of multiple biophysical signals, CM-RAM technologies can allow for the acquisition of high-volume big data for the development of algorithms to facilitate early detection of negative changes in patient health status and timely clinician response. In this article, we review key principles, architecture, and components of CM-RAM technologies. Work to date in this field and related implications are also presented, including strategic priorities for advancing the science and practice of CM-RAM.
L’objectif de rendre le système de santé plus efficace tout en étant proche des patients et de réduire le recours aux services de santé tertiaires a entraîné une croissance phénoménale de l’application et de l’étude des systèmes de télésurveillance des patients dans le domaine des soins cardiovasculaires. Bien qu’il existe de nombreux produits de surveillance grand public axés sur le bien-être des patients, la réglementation de ces technologies varie considérablement, la plupart des produits ne disposant que de peu de données d’évaluation, voire aucune. À mesure que la science et la pratique des soins virtuels évoluent, les cliniciens et les chercheurs peuvent tirer profit de la compréhension de solutions plus complètes permettant de surveiller plusieurs paramètres biophysiques (par exemple, la saturation en oxygène, la fréquence cardiaque) en continu et simultanément. Ces solutions font appel à des dispositifs automatisés de télésurveillance continue multiparamétrique (DATCM), qui pourraient bien révolutionner la prise en charge virtuelle des patients. Grâce à l’intégration transparente de plusieurs signaux biophysiques, les technologies sur lesquelles reposent les DATCM permettent de recueillir de grands volumes de mégadonnées en vue du développement d’algorithmes destinés à faciliter la détection précoce des variations négatives de l’état de santé des patients et l’intervention rapide des cliniciens. Dans cet article, nous examinons les fondements, l’architecture et les composants des technologies propres aux DATCM. Nous présentons aussi les travaux réalisés jusqu’à présent en la matière ainsi que leurs implications, dont les priorités stratégiques axées sur l’évolution des aspects scientifiques et pratiques des DATCM.