Contrast-Enhanced Magnetic Resonance Lymphangiography (CE-MRL) presents some limitations: (i) it does not quantify lymphatic functionality; and (ii) enhancement of vascular structures may confound ...image interpretation. Furthermore, although CE-MRL is well described in the published literature for the lower limbs, there is a paucity of data with regards to its use in the upper limbs. In this proof-of-principle study, we propose a new protocol to perform CE-MRL in the upper limbs of patients with breast cancer-related lymphedema (BCRL) which addresses these limitations.
CE-MRL was performed using a previously published (morphological) protocol and the proposed protocol (quantitative) on both the ipsilateral (abnormal) and contralateral (normal) arms of patients with BCRL. The quantitative protocol employs contrast agent (CA) intradermal injections at a lower concentration to prevent T2*-related signal decay. Both protocols provided high-resolution three-dimensional images of upper limb lymphatic vessels. CA uptake curves were utilized to distinguish between lymphatic vessels and vascular structures. The quantitative protocol minimized venous enhancement and avoided spurious delays in lymphatic enhancement due to short T2* values, enabling correct CA uptake characterization. The quantitative protocol was therefore employed to measure the lymphatic fluid velocity, which demonstrated functional differences between abnormal and normal arms. The velocity values were in agreement with previously reported lymphoscintigraphy and near infra-red lymphangiography measurements.
This work demonstrated the feasibility of CE-MRL of the upper limbs in patients with BRCL, introducing an advanced imaging and analysis protocol suitable for anatomical and functional study of the lymphatic system.
Abstract Aim To assess the feasibility of using cine-MR to study intra-fractional time–volume and volume-deformity patterns of the bladder during radiotherapy as initial methodology for Predictive ...Organ Localization (POLO). Methods Nine patients receiving radiotherapy for localized muscle invasive bladder cancer were prospectively studied. Each had an MR scan performed on an empty bladder using a T1 weighted cine sequence over a period of 20 min. Scans were taken prior to, and repeated towards the end of, radiotherapy treatment. Time–volume sequences were determined and compared before and during radiotherapy. Absolute bladder volumes were then correlated with changes in bladder wall position. Results The mean post void residual bladder volume prior to radiotherapy at time 0 was 113 cm3 SD 53 and this did not differ significantly during radiotherapy −106 cm SD 40 ( p = 0.24, paired t -test analysis). A linear relationship was observed for the rate bladder filling over a 20 min period, which did not significantly change on the cine-MR during radiotherapy (regression coefficient 2.1 vs 1.6, respectively, p = 0.51). Significant positive relationships were seen between volume and anterior ( p = 0.02), superior ( p < 0.001), and inferior ( p = 0.03) wall motion. These relationships were complex, though linearity was observed for volumes up to 150 cm3 . The 1.5 cm CTV–PTV margin was sufficient to account for expansion in the majority of cases with the only breach occurring on the anterior wall in one patient. Conclusions This study confirms the feasibility of using cine-MR for POLO. The development of such predictive methodology may compensate for the need to use an isotropic CTV–PTV margin to simply cover bladder filling when using image-guided radiotherapy.
•AI implementation in medical imaging/radiotherapy is impeded by lack of training.•There is a distinct lack of knowledge of AI governance frameworks.•Different professionals identify different ...priorities for AI adoption.•Customised training and governance frameworks can accelerate AI implementation.
Medical Imaging and radiotherapy (MIRT) are at the forefront of artificial intelligence applications. The exponential increase of these applications has made governance frameworks necessary to uphold safe and effective clinical adoption. There is little information about how healthcare practitioners in MIRT in the UK use AI tools, their governance and associated challenges, opportunities and priorities for the future.
This cross-sectional survey was open from November to December 2022 to MIRT professionals who had knowledge or made use of AI tools, as an attempt to map out current policy and practice and to identify future needs. The survey was electronically distributed to the participants. Statistical analysis included descriptive statistics and inferential statistics on the SPSS statistical software. Content analysis was employed for the open-ended questions.
Among the 245 responses, the following were emphasised as central to AI adoption: governance frameworks, practitioner training, leadership, and teamwork within the AI ecosystem. Prior training was strongly correlated with increased knowledge about AI tools and frameworks. However, knowledge of related frameworks remained low, with different professionals showing different affinity to certain frameworks related to their respective roles. Common challenges and opportunities of AI adoption were also highlighted, with recommendations for future practice.
Objectives
To investigate whether MRI-based measurements of fibro-glandular tissue volume, breast density (MRBD), and background parenchymal enhancement (BPE) could be used to stratify two cohorts of ...healthy women: BRCA carriers and women at population risk of breast cancer.
Methods
Pre-menopausal women aged 40–50 years old were scanned at 3 T, employing a standard breast protocol including a DCE-MRI (35 and 30 participants in high- and low-risk groups, respectively). The dynamic range of the DCE protocol was characterised and both breasts were masked and segmented with minimal user input to produce measurements of fibro-glandular tissue volume, MRBD, and voxelwise BPE. Statistical tests were performed to determine inter- and intra-user repeatability, evaluate the symmetry between metrics derived from left and right breasts, and investigate MRBD and BPE differences between the high- and low-risk cohorts.
Results
Intra- and inter-user reproducibility in estimates of fibro-glandular tissue volume, MRBD, and median BPE estimations were good, with coefficients of variation < 15%. Coefficients of variation between left and right breasts were also low (< 25%). There were no significant correlations between fibro-glandular tissue volume, MRBD, and BPE for either risk group. However, the high-risk group had higher BPE kurtosis, although linear regression analysis did not reveal significant associations between BPE kurtosis and breast cancer risk.
Conclusions
This study found no significant differences or correlations in fibro-glandular tissue volume, MRBD, or BPE metrics between the two groups of women with different levels of breast cancer risk. However, the results support further investigation into the heterogeneity of parenchymal enhancement.
Key Points
•
A semi-automated method enabled quantitative measurements of fibro-glandular tissue volume, breast density, and background parenchymal enhancement with minimal user intervention
.
•
Background parenchymal enhancement was quantified over the entire parenchyma, segmented in pre-contrast images, thus avoiding region selection
.
•
No significant differences and correlations in fibro-glandular tissue volume, breast density, and breast background parenchymal enhancement were found between two cohorts of women at high and low levels of breast cancer risk
.
Image quality in whole-body MRI (WB-MRI) may be degraded by faulty radiofrequency (RF) coil elements or mispositioning of the coil arrays. Phantom-based quality control (QC) is used to identify ...broken RF coil elements but the frequency of these acquisitions is limited by scanner and staff availability. This work aimed to develop a scan-specific QC acquisition and processing pipeline to detect broken RF coil elements, which is sufficiently rapid to be added to the clinical WB-MRI protocol. The purpose of this is to improve the quality of WB-MRI by reducing the number of patient examinations conducted with suboptimal equipment. Approach: A rapid acquisition (14 seconds additional acquisition time per imaging station) was developed that identifies broken RF coil elements by acquiring images from each individual coil element and using the integral body coil. This acquisition was added to one centre's clinical WB-MRI protocol for one year (892 examinations) to evaluate the effect of this scan-specific QC. To demonstrate applicability in multi-centre imaging trials, the technique was also implemented on scanners from three manufacturers. Main Results: Over the course of the study RF coil elements were flagged as potentially broken on five occasions, with the faults confirmed in four of those cases. The method had a precision of 80 % and a recall of 100 % for detecting faulty RF coil elements. The coil array positioning measurements were consistent across scanners and have been used to define the expected variation in signal. Significance: The technique demonstrated here can identify faulty RF coil elements and positioning errors and is a practical addition to the clinical WB-MRI protocol. This approach was fully implemented on systems from three manufacturers and partially implemented on a third. It has potential to reduce the number of clinical examinations conducted with suboptimal hardware and improve image quality across multi-centre studies.
CT-based radiotherapy workflow is limited by poor soft tissue definition in the pelvis and reliance on rigid registration methods. Current image-guided radiotherapy and adaptive radiotherapy models ...therefore have limited ability to improve clinical outcomes. The advent of MRI-guided radiotherapy solutions provides the opportunity to overcome these limitations with the potential to deliver online real-time MRI-based plan adaptation on a daily basis, a true "plan of the day." This review describes the application of MRI guided radiotherapy in two pelvic tumour sites likely to benefit from this approach.
To present and evaluate an automated method to correct scaling between Dixon water/fat images used in breast density (BD) assessments.
Dixon images were acquired in 14 subjects with different
...weightings (flip angles, FA, 4°/16°). Our method corrects intensity differences between water (
) and fat (
) images via the application of a uniform scaling factor (SF), determined subject-by-subject. Based on the postulation that optimal SFs yield relatively featureless summed fat/scaled-water (
) images, each SF was chosen as that which generated the lowest 95th-percentile in the absolute spatial-gradient image-volume of
. Water-fraction maps were calculated for data acquired with low/high FAs, and BD (%) was the total percentage water within each breast volume.
Corrected/uncorrected BD ranged from, respectively, 10.9-71.8%/8.9-66.7% for low-FA data to 8.1-74.3%/5.6-54.3% for high-FA data. Corrected metrics had an average absolute increase in BD of 6.4% for low-FA data and 18.4% for high-FA data. BD values estimated from low- and high-FA data were closer following SF-correction.
Our results demonstrate need for scaling in such BD assessments, where our method brought high-FA and low-FA data into closer agreement.
We demonstrated a feasible method to address a main source of inaccuracy in Dixon-based BD measurements.
MRI has been extensively used in breast cancer staging, management and high risk screening. Detection sensitivity is paramount in breast screening, but variations of signal-to-noise ratio (SNR) as a ...function of position are often overlooked. We propose and demonstrate practical methods to assess spatial SNR variations in dynamic contrast-enhanced (DCE) breast examinations and apply those methods to different protocols and systems. Four different protocols in three different MRI systems (1.5 and 3.0 T) with receiver coils of different design were employed on oil-filled test objects with and without uniformity filters. Twenty 3D datasets were acquired with each protocol; each dataset was acquired in under 60 s, thus complying with current breast DCE guidelines. In addition to the standard SNR calculated on a pixel-by-pixel basis, we propose other regional indices considering the mean and standard deviation of the signal over a small sub-region centred on each pixel. These regional indices include effects of the spatial variation of coil sensitivity and other structured artefacts. The proposed regional SNR indices demonstrate spatial variations in SNR as well as the presence of artefacts and sensitivity variations, which are otherwise difficult to quantify and might be overlooked in a clinical setting. Spatial variations in SNR depend on protocol choice and hardware characteristics. The use of uniformity filters was shown to lead to a rise of SNR values, altering the noise distribution. Correlation between noise in adjacent pixels was associated with data truncation along the phase encoding direction. Methods to characterise spatial SNR variations using regional information were demonstrated, with implications for quality assurance in breast screening and multi-centre trials.