Absolute calibration of particle energy at VEPP-4M Blinov, V.E; Bogomyagkov, A.V; Karnaev, S.E ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
11/2002, Letnik:
494, Številka:
1
Journal Article
Recenzirano
We have started a new series of experiments on a precise measurement of
J/
Ψ-,
Ψ′- mesons and
τ-lepton masses at VEPP-4M collider with KEDR detector. Features of the method used for an absolute ...particle energy calibration based on the resonance depolarization are described.
The status of VEPP-4 Blinov, V. E.; Bobrovnikov, V. S.; Zolotarev, K. V. ...
Physics of particles and nuclei letters,
09/2014, Letnik:
11, Številka:
5
Journal Article
Recenzirano
The VEPP-4 accelerator-accumulator complex is designed for carrying out experiments with colliding electron-positron beams with the energy in the range of from 1 to 5 GeV using a VEPP-4M collider ...equipped with the KEDR magnetic detector. Experiments in the field of high-energy physics (HEP) using the complex in its present state have been being carried out since 2002. Science programs other than HEP programs are carried out in the VEPP-4, including experiments with synchrotron-radiation (SR) beams and studies on nuclear physics with an internal gas target, on verification of the CPT invariance, on accelerator physics, etc. The status of the complex, main results, methods used, new approaches, and long-term plans have been described.
STUDY OF ψ(2S) → μ+μ- DECAY WITH KEDR DETECTOR AULCHENKO, V. M; BALDIN, E. M; BARLADYAN, A. K ...
International Journal of Modern Physics: Conference Series,
2014, Letnik:
35
Journal Article, Conference Proceeding
Recenzirano
Since 2004 the KEDR detector at the VEPP-4M collider has taken several data sets in the ψ(2S) region, acquiring total luminosity of about 7 pb-1, which corresponds to more than 3.5 × 106ψ(2S).
We ...report the preliminary value of Γee × Γμμ/Γ = 19.4 ± 0.4 ± 1.1 eV for ψ(2S).
PARAMETERS OF CHARMONIUM STATES FROM KEDR AULCHENKO, V. M; BALDIN, E. M; BARLADYAN, A. K ...
International Journal of Modern Physics: Conference Series,
2014, Letnik:
35
Journal Article, Conference Proceeding
Recenzirano
Odprti dostop
We report results of experiments performed with the KEDR detector at the VEPP-4M e+e- collider. They include final results for the mass and other parameters of the J/ψ, ψ(2S) and ψ(3770) and J/ψ → ...γηc branching fraction determination.
Designs of grid units with slotted and multiple-aperture configurations of holes that allow an increase in the stability of the current-cutoff process and a reduction in the time to turn the device ...off in a high-voltage pulse generator with an inductive energy storage were created. Compared to a TGI2-500/20 thyratron, these designs made it possible to reduce the time instability of the instant of the current interruption by factors of 2 and 5 for switches with the multiple-aperture and slotted configurations of the grids, respectively. These constructions allowed the minimum time for disabling a device to be reduced by 25%.
The electron–ion scattering experiment ELISe is part of the installations envisaged at the new experimental storage ring at the International Facility for Antiproton and Ion Research (FAIR) in ...Darmstadt, Germany. It offers an unique opportunity to use electrons as probe in investigations of the structure of exotic nuclei. The conceptual design and the scientific challenges of ELISe are presented.
The VEPP-4M accelerator facility with a universal KEDR detector is designed to conduct experiments with colliding electron-positron beams. High-energy physics, nuclear physics, and studies using ...synchrotron radiation are the main directions of research with this facility. In addition, experiments on poorly explored issues in the physics of beams in the electron-positron storage ring and methodological studies to prepare an experiment aimed at testing corollaries of the CPT theorem for an electron and a positron are regularly conducted at the VEPP-4 facility. A number of works performed in recent years are described: studies to increase the accuracy of comparing the electron and positron spin precession frequencies by the resonant depolarization method; measurements of the count rate of Touschek electrons as a function of the beam energy in a wide range; comparison of the methods for measuring the beam energy spread; a study of the electron beam dynamics when a nonlinear betatron resonance is crossed.
The use of nonlinear lattices with large betatron tune spreads can increase instability and space charge thresholds due to improved Landau damping. Unfortunately, the majority of nonlinear ...accelerator lattices turn out to be nonintegrable, producing chaotic motion and a complex network of stable and unstable resonances. Recent advances in finding the integrable nonlinear accelerator lattices have led to a proposal to construct at Fermilab a test accelerator with strong nonlinear focusing which avoids resonances and chaotic particle motion. This presentation will outline the main challenges, theoretical design solutions and construction status of the Integrable Optics Test Accelerator underway at Fermilab.