This report summarizes the physics, technology and clinical application of ultrasound biomicroscopy (UBM) of the eye, in which frequencies of 35 MHz and above provide over a threefold improvement in ...resolution compared with conventional ophthalmic ultrasound systems. UBM allows imaging of anatomy and pathology involving the anterior segment, including regions obscured by overlying optically opaque anatomic or pathologic structures. UBM provides diagnostically significant information in conditions such as glaucoma, cysts and neoplasms, trauma and foreign bodies. UBM also can provide crucial biometric information regarding anterior segment structures, including the cornea and its constituent layers and the anterior and posterior chambers. Although UBM has now been in use for over 15 years, new technologies, including transducer arrays, pulse encoding and combination of ultrasound with light, offer the potential for significant advances in high‐resolution diagnostic imaging of the eye.
Ultrasound imaging of the eye was introduced over 50 years ago. While the physical principles of ultrasound imaging have not changed, technology has undergone tremendous and ongoing development.
The ...fundamentals of ultrasound physics, biometry (A-scan), structural imaging (B-scan) and blood-flow imaging and measurement (Doppler) will be described. Emphasis will be placed on technological development and potential future advances.
While A- and B-scan ultrasound of the eye has traditionally been performed with focused single-element transducers, the introduction of annular and linear arrays has enhanced clinical utility. Future advances, especially in multielement arrays, and point-of-care systems promise amazing new capabilities for diagnostic imaging of the eye and orbit.
Ocular blood flow in preterm neonates Silverman, Ronald H; Urs, Raksha; Horowitz, Jason D ...
Scientific reports,
04/2024, Letnik:
14, Številka:
1
Journal Article
Recenzirano
Odprti dostop
Retinopathy of prematurity (ROP) is a disorder affecting low birthweight, preterm neonates. In the preterm eye, the retina is not fully developed and neovascularization may occur at the margin ...between the developed vascular retina and undeveloped avascular retina. Without timely treatment by laser or intravitreal anti-vascular endothelial growth factor (VEGF) therapy, this can lead to tractional retinal detachment and blindness. Visualization of the retina in regular examinations by indirect ophthalmoscopy is hence the current standard of care, but the exams are stressful and interpretation of images is subjective. The upregulation of VEGF in ROP would suggest an increase in ocular blood flow. In this report, we evaluate the potential of ultrafast plane-wave Doppler ultrasound (PWU) to detect increased flow velocities in the orbital vessels supplying the eye in a gentle exam with objective findings. We imaged both eyes of 50 low-birthweight preterm neonates using 18 MHz PWU. Flow velocity in the central retinal artery (CRA) and vein (CRV), and the short posterior ciliary arteries were determined and values at each ROP Stage compared. We found significantly increased velocities in the CRA and CRV in Stage 3 ROP eyes, where intervention would be considered. We compared multivariate models for identifying Stage 3 eyes comprised solely of clinical factors, solely of Doppler parameters, and clinical plus Doppler parameters. The respective models provided areas under their respective ROC curves of 0.760, 0.812, and 0.904. PWU Doppler represents a gentle, objective means for identifying neonates at risk for ROP that could complement ophthalmoscopy.
Ophthalmic ultrasound imaging is currently performed with mechanically scanned single-element probes. These probes have limited capabilities overall and lack the ability to image blood flow. ...Linear-array systems are able to detect blood flow, but these systems exceed ophthalmic acoustic intensity safety guidelines. Our aim was to implement and evaluate a new linear-array-based technology, compound coherent plane-wave ultrasound, which offers ultrafast imaging and depiction of blood flow at safe acoustic intensity levels.
We compared acoustic intensity generated by a 128-element, 18-MHz linear array operated in conventionally focused and plane-wave modes and characterized signal-to-noise ratio (SNR) and lateral resolution. We developed plane-wave B-mode, real-time color-flow, and high-resolution depiction of slow flow in postprocessed data collected continuously at a rate of 20,000 frames/s. We acquired in vivo images of the posterior pole of the eye by compounding plane-wave images acquired over ±10° and produced images depicting orbital and choroidal blood flow.
With the array operated conventionally, Doppler modes exceeded Food and Drug Administration safety guidelines, but plane-wave modalities were well within guidelines. Plane-wave data allowed generation of high-quality compound B-mode images, with SNR increasing with the number of compounded frames. Real-time color-flow Doppler readily visualized orbital blood flow. Postprocessing of continuously acquired data blocks of 1.6-second duration allowed high-resolution depiction of orbital and choroidal flow over the cardiac cycle.
Newly developed high-frequency linear arrays in combination with plane-wave techniques present opportunities for the evaluation of ocular anatomy and blood flow, as well as visualization and analysis of other transient phenomena such as vessel wall motion over the cardiac cycle and saccade-induced vitreous motion.
To develop and evaluate automated computerized algorithms for differentiation of normal and keratoconus corneas based solely on epithelial and stromal thickness data.
Maps of the corneal epithelial ...and stromal thickness were generated from Artemis-1 very high-frequency ultrasound arc-scans of 130 normal and 74 keratoconic subjects diagnosed by combined topography and tomography examination. Keratoconus severity was graded based on anterior curvature, minimum corneal thickness, and refractive error. Computer analysis of maps produced 161 features for one randomly selected eye per subject. Stepwise linear discriminant analysis (LDA) and neural network (NN) analysis were then performed to develop multivariate models based on combinations of selected features to correctly classify cases. The sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were determined for each classifier.
Stepwise LDA resulted in a six-variable model that provided an AUC of 100%, indicative of complete separation of keratoconic from normal corneas. Leave-one-out analysis resulted in 99.2% specificity and 94.6% sensitivity. Neural network analysis using the same six variables resulted in an AUC of 100% for the training set. Test set performance averaged over 10 trials gave a specificity of 99.5 ± 1.5% and sensitivity of 98.9 ± 1.9%. The LDA function values correlated with keratoconus severity grade.
The results demonstrate that epithelial remodeling in keratoconus represents an independent means for differentiation of normal from advanced keratoconus corneas.
To assess the effectiveness of a keratoconus-detection algorithm derived from Artemis very high-frequency (VHF) digital ultrasound (ArcScan Inc., Morrison, CO) epithelial thickness maps in the fellow ...eye from a series of patients with unilateral keratoconus.
The study included 10 patients with moderate to advanced keratoconus in one eye but a clinically and algorithmically topographically normal fellow eye. VHF digital ultrasound epithelial thickness data were acquired and a previously developed classification model was applied for identification of keratoconus to the clinically normal fellow eyes. Pentacam (Oculus Optikgeräte, Wetzlar, Germany) Belin-Ambrósio Enhanced Ectasia Display "D" score (BAD-D) data (5 of 10 eyes), and Orbscan (Bausch & Lomb, Rochester, NY) SCORE data (9 of 10 eyes) were also evaluated.
Five of the 10 fellow eyes were classified as keratoconic by the VHF digital ultrasound epithelium model. Five of 9 fellow eyes were classified as keratoconic by the SCORE model. For the 5 fellow eyes with Pentacam and VHF digital ultrasound data, one was classified as keratoconic by the VHF digital ultrasound model, one (different) eye by a combined VHF digital ultrasound and Pentacam model, and none by BAD-D alone.
Under the assumption that keratoconus is a bilateral but asymmetric disease, half of the 'normal' fellow eyes could be found to have keratoconus using epithelial thickness maps. The Orbscan SCORE or the combination of topographic BAD-D criteria with epithelial maps did not perform better.
Neodymium:yttrium-aluminum-garnet (Nd:YAG) laser treatment is performed on vitreous floaters, but studies of structural and functional effects with objective outcome measures are lacking. This study ...evaluated Nd:YAG laser effects by comparing participants with vitreous floaters who previously underwent laser treatment with untreated control participants and healthy persons without vitreous floaters using quantitative ultrasonography to evaluate vitreous structure and by measuring visual acuity and contrast sensitivity function to assess vision.
Retrospective, comparative study.
One eye was enrolled for each of 132 participants: 35 control participants without vitreous floaters, 59 participants with untreated vitreous floaters, and 38 participants with vitreous floaters previously Nd:YAG-treated. Of these, 25 were dissatisfied and sought vitrectomy; 13 were satisfied with observation.
The 39-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-39) to assess participant visual well-being, quantitative ultrasonography (QUS) to measure vitreous echodensity, and best-corrected visual acuity (BCVA) and contrast sensitivity function (CSF) to evaluate vision.
Results of NEI-VFQ-39, QUS, BCVA, and CSF.
Compared with control participants without vitreous floaters, participants with untreated vitreous floaters showed worse NEI-VFQ-39 results, 57% greater vitreous echodensity, and significant (130%) CSF degradation (P < 0.001 for each). Compared with untreated eyes with vitreous floaters, Nd:YAG-treated eyes had 23% less vitreous echodensity (P < 0.001), but no differences in NEI-VFQ-39 (P = 0.51), BCVA (P = 0.42), and CSF (P = 0.17) results. Of 38 participants with vitreous floaters who previously were treated with Nd:YAG, 25 were dissatisfied and seeking vitrectomy, whereas 13 were satisfied with observation. Participants seeking vitrectomy showed 24% greater vitreous echodensity (P = 0.018) and 52% worse CSF (P = 0.006). Multivariate linear regression models confirmed these findings.
As a group, participants previously treated with Nd:YAG laser for bothersome vitreous floaters showed less dense vitreous, but similar visual function as untreated control participants with vitreous floaters. Because some treated eyes showed less dense vitreous and better visual function than those of untreated control participants, a prospective randomized study of Nd:YAG laser treatment of vitreous is warranted, using uniform laser treatment parameters and objective quantitative outcome measures.
Preeclampsia (PE) is a severe complication of pregnancy characterized by hypertension, proteinuria and compromised fetal blood supply. The eye, like other end organs, is affected by this systemic ...condition, but unlike in other organs, ocular media transparency allows high-resolution optical visualization of the vascular structure of the retina. Our aim was to assess how ultrasound-determined ocular blood-flow correlates with vascular structure of the retina and choriocapillaris determined by optical coherence tomography angiography (OCTA).
Plane-wave ultrasound and OCTA were performed on both eyes of 40 consecutive subjects consisting of normal controls (n = 11), mild PE (n = 5), severe PE (n = 17) and chronic or gestational hypertension (n = 7) within 72 hours following delivery. From ultrasound, we measured pulsatile flow velocity and resistance indices in the central retinal artery (CRA) and vein, the short posterior ciliary arteries (SPCAs) and choroid. From OCTA, we measured vascular density (VD) in the superficial, deep retina and choriocapillaris. We determined differences in Doppler and OCTA parameters among groups and correlations between ultrasound and OCTA.
In severe PE, flow resistance was reduced with respect to controls. Flow velocity and resistance in the and SPCA were moderately correlated with VD in the choriocapillaris and peripapillary retina, but VD in PE did not differ significantly from controls.
Although OCTA parameters were moderately correlated with Doppler ultrasound, OCTA did not demonstrate significant differences between PE and controls postpartum.
The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ...ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via ciliodestruction), tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities.
To compare measurements of corneal epithelial thickness using optical coherence tomography (OCT) and very high-frequency digital ultrasound (VHFDU).
Retrospective analysis of 189 virgin corneas and ...175 post-laser refractive surgery (LRS) corneas that had corneal epithelial thickness measurement with RTVue Fourier-domain OCT (Optovue, Inc., Fremont, CA) (tear film included) and Artemis VHFDU (ArcScan Inc., Morrison, CO) (tear film excluded). Averages were calculated for the central 2-mm diameter zone and for two further concentric annuli of 1.5- and 0.5-mm width, each divided into eight sectors. Agreement was analyzed by mean difference (OCT - VHFDU), 95% limits of agreement (LoA) (1.96 standard deviation of the difference), and Bland-Altman analysis.
In virgin epithelium, mean central thickness was 53.4 ± 3.20 µm (range: 46 to 62 µm) with OCT and 54.1 ± 2.96 µm (range: 48 to 61 µm) with VHFDU; OCT measured thinnest in 70% with a mean difference of -0.71 µm (95% LoA of ± 3.94 µm, P < .001). In post-LRS epithelium, mean central thickness was 57.9 ± 6.08 µm (range: 42 to 77 µm) with OCT and 60.5 ± 6.47 µm (range: 42 to 79 µm) with VHFDU; OCT measured thinnest in 88%, with a mean difference of -2.48 µm (95% LoA of ± 5.33 µm, P < .001). A larger difference between methods was more common with thicker epithelium.
Corneal epithelial thickness measurements using OCT were found to be slightly thinner than for VHFDU. In contrast to VHFDU, OCT measurement includes the tear film, so the true difference is probably approximately 4 µm more than reported. The difference was greatest inferiorly and higher for post-LRS eyes and in thicker epithelium.