FLAG Review 2021 Aoki, Y.; Blum, T.; Colangelo, G. ...
The European physical journal. C, Particles and fields,
10/2022, Letnik:
82, Številka:
10
Journal Article
Recenzirano
Odprti dostop
We review lattice results related to pion, kaon,
D
-meson,
B
-meson, and nucleon physics with the aim of making them easily accessible to the nuclear and particle physics communities. More ...specifically, we report on the determination of the light-quark masses, the form factor
f
+
(
0
)
arising in the semileptonic
K
→
π
transition at zero momentum transfer, as well as the decay constant ratio
f
K
/
f
π
and its consequences for the CKM matrix elements
V
us
and
V
ud
. Furthermore, we describe the results obtained on the lattice for some of the low-energy constants of
S
U
(
2
)
L
×
S
U
(
2
)
R
and
S
U
(
3
)
L
×
S
U
(
3
)
R
Chiral Perturbation Theory. We review the determination of the
B
K
parameter of neutral kaon mixing as well as the additional four
B
parameters that arise in theories of physics beyond the Standard Model. For the heavy-quark sector, we provide results for
m
c
and
m
b
as well as those for the decay constants, form factors, and mixing parameters of charmed and bottom mesons and baryons. These are the heavy-quark quantities most relevant for the determination of CKM matrix elements and the global CKM unitarity-triangle fit. We review the status of lattice determinations of the strong coupling constant
α
s
. We consider nucleon matrix elements, and review the determinations of the axial, scalar and tensor bilinears, both isovector and flavor diagonal. Finally, in this review we have added a new section reviewing determinations of scale-setting quantities.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Highlights • Kinect sensor was used as a markerless motion capture system (MLS). • Results were compared with marker based system (MBS). • Four kind of motions were performed. • Measured range of ...motion was found statistically different between systems. • MLS reproducibility was found to be statistically similar to MBS.
Abstract In the last decade, technological advances in the gaming industry have allowed the marketing of hardware for motion and balance control that is based on technological concepts similar to ...scientific and clinical equipment. Such hardware is attractive to researchers and clinicians for specific applications. However, some questions concerning their scientific value and the range of future potential applications have yet to be answered. This article attempts to present an objective analysis about the pros and cons of using such hardware for scientific and clinical purposes and calls for a constructive discussion based on scientific facts and practical clinical requests that are emerging from application fields.
•Reviewed the use of serious games in rehabilitation of CP children.•31 studies were included.•There is a lack of standardization in the outcome measurement.•There is a limited evidence to support ...the use of SG with CP children.•Solutions exist to improve standardization, but require clinical acceptance prior to full implementation.
The use of video games in rehabilitation is becoming more popular to clinicians. These games are embedded in off-the-shelf commercial entertainment applications or especially-developed for clinical purposes. Treatment of cerebral palsy (CP) children is a challenging task for clinicians. Lack of motivation and progress monitoring are two important factors clinicians need to deal with. The use of serious games (SG), sometimes referred to as Virtual Rehabilitation (VR), could therefore be an interesting adjuvant to conventional treatment for these patients. This is however a new discipline and many scientific issues remain to be solved. The aim of this paper is to describe available conventional treatment for CP children together with the level of evidence of each approach. A systematic review of the use of SG in rehabilitation is then conducted. 31 papers (7 randomized clinical trials, 16 cohort studies and 8 single-cases studies) were selected and analyzed, and their level of evidence compared to the conventional treatment. These studies reported outcomes for 352 patients. In summary, this review shows that it is difficult to compare those studies despite the large amount of patients. This is due to the lack of standardization in patient rehabilitation strategy and to the use of various clinical scales and scores. This non-standardization in patient follow-up between previously-published works make evidence-based conclusions difficult to obtain in order to support these techniques objectively. The use of SG for rehabilitation purposes currently meets similar issues. This paper proposes standardization strategies in order to improve treatment comparison and SG use in rehabilitation.
Highlights • Maturation and decline of nervous system affects motor control and function. • Serious games are becoming popular in rehabilitation. • Motions analysis is combined with rehabilitation ...exercises embedded in serious games. • Patterns of the motions are correlated with age. • Serious games can be used to perform functional evaluation
The recent availability of the Kinect™ sensor, a low-cost Markerless Motion Capture (MMC) system, could give new and interesting insights into ergonomics (e.g. the creation of a morphological ...database). Extensive validation of this system is still missing. The aim of the study was to determine if the Kinect™ sensor can be used as an easy, cheap and fast tool to conduct morphology estimation. A total of 48 subjects were analysed using MMC. Results were compared with measurements obtained from a high-resolution stereophotogrammetric system, a marker-based system (MBS). Differences between MMC and MBS were found; however, these differences were systematically correlated and enabled regression equations to be obtained to correct MMC results. After correction, final results were in agreement with MBS data (p = 0.99). Results show that measurements were reproducible and precise after applying regression equations. Kinect™ sensors-based systems therefore seem to be suitable for use as fast and reliable tools to estimate morphology.
Practitioner Summary: The Kinect™ sensor could eventually be used for fast morphology estimation as a body scanner. This paper presents an extensive validation of this device for anthropometric measurements in comparison to manual measurements and stereophotogrammetric devices. The accuracy is dependent on the segment studied but the reproducibility is excellent.
Abstract
Data models are the backbone of digital information exchange, since they contain the structure of data to be exchanged. Just as information requirements vary, so do data models – in level of ...detail, level of abstraction, and domain coverage. Due to these differences, communication between some data models is easy and between others is difficult. Regarding the Building Information Model (BIM) initiative, the IFC standard data model varies in detail, abstraction level, and large domain coverage. In contrast, the Austrian ÖGG-guideline has a consistent detail and abstraction level focusing on a single domain, subsurface engineering. In order to participate in a loss- and distortion-free information exchange, a reliable translation via a multitude of data models is a must-have.
In this paper, we present formal criteria for distinguishing between semantics-carrying data models, such as IFC and ÖGG, and translating data models that provide reliable communication bridges between them, such as CAEX and SIMULTAN. We will show that translating data models are an indispensable part of the data model infrastructure even within a single domain. For evaluation purpose, we demonstrate our approach on a subsurface engineering use case.
Biomedical science and its allied disciplines are entering a new era in which computational methods and technologies are poised to play a prevalent role in supporting collaborative investigation of ...the human body. Within Europe, this has its focus in the virtual physiological human (VPH), which is an evolving entity that has emerged from the EuroPhysiome initiative and the strategy for the EuroPhysiome (STEP) consortium. The VPH is intended to be a solution to common infrastructure needs for physiome projects across the globe, providing a unifying architecture that facilitates integration and prediction, ultimately creating a framework capable of describing Homo sapiens in silico. The routine reliance of the biomedical industry, biomedical research and clinical practice on information technology (IT) highlights the importance of a tailor-made and robust IT infrastructure, but numerous challenges need to be addressed if the VPH is to become a mature technological reality. Appropriate investment will reap considerable rewards, since it is anticipated that the VPH will influence all sectors of society, with implications predominantly for improved healthcare, improved competitiveness in industry and greater understanding of (patho)physiological processes. This paper considers issues pertinent to the development of the VPH, highlighted by the work of the STEP consortium.
Objective
The Psychosocial Assessment Tool (PAT) was developed to screen for psychosocial risk, aimed to be supportive in directing psychosocial care to families of a child with cancer. This study ...aimed to determine (i) the match between PAT risk score and provided psychosocial care with healthcare professionals blind to outcome of PAT assessment, and (ii) the match between PAT risk score and team risk estimation.
Methods
Eighty‐three families of children with cancer from four pediatric oncology centers in the Netherlands participated (59% response rate). The PAT and team risk estimation was assessed at diagnosis (M = 40.2 days, SD = 14.1 days), and the content of provided psychosocial care in the 5‐month period thereafter resulting in basic or specialized care.
Results
According to the PAT, 65% of families were defined as having low (universal), 30% medium (targeted), and 5% high (clinical) risk for developing psychosocial problems. Thirty percent of patients from universal group got basic psychosocial care, 63% got specialized care, and 7% did not get any care. Fourteen percent of the families at risk got basic care, 86% got specialized care. Team risk estimations and PAT risk scores matched with 58% of the families.
Conclusions
This study showed that families at risk, based on standardized risk assessment with the PAT, received more specialized care than families without risk. However, still 14% of the families with high risks only received basic care, and 63% of the families with standard risk got specialized care. Standardized risk assessment can be used as part of comprehensive care delivery, complementing the team.
•Breathing pattern or pulmonary pathologies influence the balance.•There is a lack of tool to easily assess balance under various inspiratory loads.•Wii Balance Board has not been validated yet in ...this context.•WBB can be used detect the effect of breathing on the balance of young healthy subjects.
There is a link between breathing and balance and posture. When the inspiratory loads are increased by pathologies, there is a decrease of postural control. The increase of the inspiratory load on respiratory muscles is a common feature in various chronic pulmonary pathologies. Consequently, the balance of those patients is likely affected.
The aim of this study is to validate the use of the Nintendo Wii Balance Board (WBB) to assess balance modifications induced by increased respiratory loads in healthy subjects.
Thirty-seven healthy young participants (25 ± 4 years old, 17 women) participated in this study. Five different conditions were tested: without anything (control), throughout a mouthpiece, and throughout three inspiratory threshold loads (ITL) at 10% (low), 40% (mid) and 60% (high) of the maximal inspiratory pressure. Each trial lasted for 60 s. Nine parameters were extracted based on center of pressure displacement based on a previously-validated method. ANOVA tests were used to compare the different conditions followed by Bonferroni’s corrections.
Highly statistically significant differences (all p < 0.01) and large effect sizes (all ω2 > 0.24) were obtained for all parameters between the different loads and the mouthpiece condition. There is a linear relationship between the load and balance perturbation.
In this study, we demonstrated the validity of the WBB to detect the effect of the inspiratory load on balance in young healthy subjects. Further studies are needed to determine if such a kind of evaluation can be used in clinics with patients suffering from chronic respiratory disease.