The aim of this prospective study was to investigate the accuracy and inter-observer reliability of MRI in detection of local recurrence (LR) of pancreatic adenocarcinoma (PAC) after surgery, which ...was proved by PET-CT and access correlation between functional MRI and PET parameters. Forty-five patients who underwent PET-CT and MRI for follow-up purposes after radical operation of PAC were included. Twenty-three were PET positive (study group) and 22 negative for LR (control group). MR examination was performed within one month after PET-CT and three readers who were blind for PET-CT findings searched LR in T2W, 3D-dynamic post-contrast T1W-FS and DWI sequences, respectively. Sensitivity and specificity were calculated while inter-reader agreement was estimated by Cronbach’s Alpha reliability coefficient (CARC). Apparent diffusion coefficient (ADC) of LR was correlated with the size (maximal diameter) and functional PET-CT parameters: mean and maximum standardized uptake values (SUVmean, SUVmax), metabolic tumor volume (MTV) and total lesion glycolysis (TLG), using Spearman’s correlation coefficient (r
S
). Sensitivity and specificity among three readers in detecting the LR were 70% and 77–84% in T2W (CARC 0.806), 91–100% and 100% in 3D post-contrast T1W-FS (CARC 0.980), and both 100% in DWI sequences (CARC 1.000). Moderate inverse correlation was found between the ADC and SUVmean (
r
S
= − 0.484), MTV (
r
S
= − 0.494), TLG (
r
S
= − 0.519) and lesion size (
r
S
= − 0.567). MRI with DWI shows high diagnostic accuracy in detecting the LR of PAC in comparison to PET-CT as reference standard. ADC significantly inversely correlates with standard and advanced PET parameters and size of LR.
Abstract Purpose Standardized perfusion value (SPV) is a universal indicator of tissue perfusion, normalized to the whole-body perfusion, which was proposed to simplify, unify and allow the ...interchangeability among the perfusion measurements and comparison between the tumor perfusion and metabolism. The aims of our study were to assess the standardized perfusion value (SPV) of the esophageal carcinoma, and its correlation with quantitative CT perfusion measurements: blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) of the same tumor volume samples, which were obtained by deconvolution-based CT perfusion analysis. Methods Forty CT perfusion studies of the esophageal cancer were analyzed, using the commercial deconvolution-based CT perfusion software (Perfusion 3.0, GE Healthcare). The SPV of the esophageal tumor and neighboring skeletal muscle were correlated with the corresponding mean tumor and muscle quantitative CT perfusion parameter values, using Spearman's rank correlation coefficient ( r S ). Results Median SPV of the esophageal carcinoma (7.1; range: 2.8–13.4) significantly differed from the SPV of the skeletal muscle (median: 1.0; range: 0.4–2.4), ( Z = −5.511, p < 0.001). The cut-off value of the SPV of 2.5 enabled discrimination of esophageal cancer from the skeletal muscle with sensitivity and specificity of 100%. SPV of the esophageal carcinoma significantly correlated with corresponding tumor BF ( r S = 0.484, p = 0.002), BV ( r S = 0.637, p < 0.001) and PS ( r S = 0.432, p = 0.005), and SPV of the skeletal muscle significantly correlated with corresponding muscle BF ( r S = 0.573, p < 0.001), BV ( r S = 0.849, p < 0.001) and PS ( r S = 0.761, p < 0.001). Conclusions We presented a database of the SPV for the esophageal cancer and proved that SPV of the esophageal neoplasm significantly differs from the SPV of the skeletal muscle, which represented a sample of healthy tissue. The SPV was validated against quantitative CT perfusion measurements and statistically significant correlation was proved.
Higher intensity of FDG uptake on PET/CT in primary tumor is seen in patients with IDC compared to ILC, also in high grade tumours, tumours with negative ER and higher Ki67 values, while data are ...inconsistent in case of relation between primary tumor's PgR and HER2 expression with its metabolic activity levels. On account of the lack of studies that include research of breast cancer metastatic lesion metabolism level and its relation to tumor histology and biology, our goal was to investigate the association of metastatic lesions' glucose metabolism level on PET/CT with different histological and biological characteristics of primary tumor. In a total number of N=100 patients, highest SUVmax values for each patient were used in testing difference between metastatic metabolic activity in patients with different tumor histology, grade, ER, PgR and HER2 status, subtype, as well in testing relation of Ki67 index to metastasis' metabolism level. In testing difference between histological types of breast cancer, SUVmax values were also compared separately for each specific anatomical site (regional and distant lymph nodes, bones and liver). No difference was found regarding metastatic SUVmax values in patients with primary IDC (n=55, median SUVmax 9.70) and ILC (n=34, median SUVmax 7.20) independently of anatomic site, and for each of analysed sites separately. No difference was found as well between SUVmax detected in metastasis in patients with different grade (grade II: n=58, median SUVmax 7.70; grade III: n=12, median SUVmax 10.20), ER (59 positive, median SUVmax 8.50; 22 negative, median SUVmax 8.05), PgR (55 positive, median SUVmax 8.50; 23 negative, median SUVmax 7.80), and HER2 (14 positive, median SUVmax 6.84; 51 negative, median SUVmax 8.63) expression in primary tumor, and between patients with different tumor subtype. Ki67 was also not associated with tumor metastatic SUVmax values (n=11, rs = -0.21, p=0.53). We conclude that there is no association of primary breast cancer histological type, grade, ER, PgR, HER2 and Ki67 expression with metabolic activity in metastasis detected on PET/CT.
Consistency of results between different readers is an important issue in medical imaging, as it affects portability of results between institutions and may affect patient care. The International ...Atomic Energy Agency (IAEA) in pursuing its mission of fostering peaceful applications of nuclear technologies has supported several training activities in the field of nuclear cardiology (NC) and SPECT myocardial perfusion imaging (MPI) in particular. The aim of this study was to verify the outcome of those activities through an international clinical audit on MPI where participants were requested to report on studies distributed from a core lab.
The study was run in two phases: in phase 1, SPECT MPI studies were distributed as raw data and full processing was requested as per local practice. In phase 2, images from studies pre-processed at the core lab were distributed. Data to be reported included summed stress score (SSS); summed rest score (SRS); summed difference score (SDS); left ventricular (LV) ejection fraction (EF) and end- diastolic volume (EDV). Qualitative appraisals included the assessment of perfusion and presence of ischemia, scar or mixed patterns, presence of transient ischemic dilation (TID), and risk for cardiac events (CE). Twenty-four previous trainees from low- and middle-income countries participated (core participants group) and their results were assessed for inter-observer variability in each of the two phases, and for changes between phases. The same evaluations were performed for a group of eleven international experts (experts group). Results were also compared between the groups.
Expert readers showed an excellent level of agreement for all parameters in both phase 1 and 2. For core participants, the concordance of all parameters in phase 1 was rated as good to excellent. Two parameters which were re-evaluated in phase 2, namely SSS and SRS, showed an increased level of concordance, up to excellent in both cases. Reporting of categorical variables by expert readers remained almost unchanged between the two phases, while core participants showed an increase in phase 2. Finally, pooled LVEF values did not show a significant difference between core participants and experts. However, significant differences were found between LVEF values obtained using different software packages for cardiac analysis.
In this study, inter-observer agreement was moderate-to-good for core group readers and good-to-excellent for expert readers. The quality of reporting is affected by the quality of processing. These results confirm the important role of the IAEA training activities in improving imaging in low- and middle-income countries.
Our aim was to assess clinical utility of 99mTc-EDDA/HYNIC-TOC scintigraphy for evaluation of lung lesions in patients with neuroendocrine tumors (NETs). Single photon emission computed tomography ...(SPECT) of the thorax and whole body scintigraphy were performed in 34 patients using 99mTc-EDDA/HYNIC-TOC. Visual assessment was complemented by semiquantitative evaluation based on tumor to non-tumor (T/NT) ratio. Clinical, laboratory, and histological findings served as the standard for comparison. Enhanced tracer uptake was observed on both SPECT and whole body scintigraphy in 29 of 34 patients (88% sensitivity). T/NT ratios were significantly higher on SPECT than whole body images (2.96+/-1.07 vs.1.70+/-0.43, p
99mTc-EDDA/Hynic-TOC, lung involvement of NETs, T/NT ratio.