This phase 3 pivotal study evaluated the safety, efficacy, and pharmacokinetics of a recombinant FVIII Fc fusion protein (rFVIIIFc) for prophylaxis, treatment of acute bleeding, and perioperative ...hemostatic control in 165 previously treated males aged ≥12 years with severe hemophilia A. The study had 3 treatment arms: arm 1, individualized prophylaxis (25-65 IU/kg every 3-5 days, n = 118); arm 2, weekly prophylaxis (65 IU/kg, n = 24); and arm 3, episodic treatment (10-50 IU/kg, n = 23). A subgroup compared recombinant FVIII (rFVIII) and rFVIIIFc pharmacokinetics. End points included annualized bleeding rate (ABR), inhibitor development, and adverse events. The terminal half-life of rFVIIIFc (19.0 hours) was extended 1.5-fold vs rFVIII (12.4 hours; P < .001). Median ABRs observed in arms 1, 2, and 3 were 1.6, 3.6, and 33.6, respectively. In arm 1, the median weekly dose was 77.9 IU/kg; approximately 30% of subjects achieved a 5-day dosing interval (last 3 months on study). Across arms, 87.3% of bleeding episodes resolved with 1 injection. Adverse events were consistent with those expected in this population; no subjects developed inhibitors. rFVIIIFc was well-tolerated, had a prolonged half-life compared with rFVIII, and resulted in low ABRs when dosed prophylactically 1 to 2 times per week. This trial was registered at www.clinicaltrials.gov as #NCT01181128.
Key Points
A fusion protein comprising factor IX and the dimeric Fc domain of IgG1 has a half-life that is five times as long as that of native factor IX, allowing prophylactic injections to be spaced as far as ...2 weeks apart while maintaining levels of factor IX that are sufficient to prevent bleeding.
In patients with severe hemophilia B, recurrent bleeding leads to painful hemarthroses, disabling hemophilic arthropathy, and other sequelae.
1
,
2
Prophylactic replacement of coagulation factor IX is associated with improved clinical outcomes
3
–
7
; however, the relatively short half-lives of currently available factor IX products necessitate frequent intravenous injections (two or three times weekly) to maintain protective levels (at or above 1 IU per deciliter).
8
,
9
The frequency of injections is a considerable burden, cited by patients as a key deterrent to undertaking prophylactic treatment.
10
Various strategies to reduce this burden and improve the treatment of hemophilia B are under investigation, . . .
Factor VIII (FVIII) replacement products enable comprehensive care in hemophilia A. Treatment goals in severe hemophilia A are expanding beyond low annualized bleed rates to include long-term ...outcomes associated with high sustained FVIII levels. Endogenous von Willebrand factor (VWF) stabilizes and protects FVIII from degradation and clearance, but it also subjects FVIII to a half-life ceiling of ∼15 to 19 hours. Increasing recombinant FVIII (rFVIII) half-life further is ultimately dependent upon uncoupling rFVIII from endogenous VWF. We have developed a new class of FVIII replacement, rFVIIIFc-VWF-XTEN (BIVV001), that is physically decoupled from endogenous VWF and has enhanced pharmacokinetic properties compared with all previous FVIII products. BIVV001 was bioengineered as a unique fusion protein consisting of a VWF-DʹD3 domain fused to rFVIII via immunoglobulin-G1 Fc domains and 2 XTEN polypeptides (Amunix Pharmaceuticals, Inc, Mountain View, CA). Plasma FVIII half-life after BIVV001 administration in mice and monkeys was 25 to 31 hours and 33 to 34 hours, respectively, representing a three- to fourfold increase in FVIII half-life. Our results showed that multifaceted protein engineering, far beyond a few amino acid substitutions, could significantly improve rFVIII pharmacokinetic properties while maintaining hemostatic function. BIVV001 is the first rFVIII with the potential to significantly change the treatment paradigm for severe hemophilia A by providing optimal protection against all bleed types, with less frequent doses. The protein engineering methods described herein can also be applied to other complex proteins.
•BIVV001 is a novel fusion protein that provides fourfold longer hemostatic control than rFVIII in preclinical hemophilia A models.•BIVV001 has the potential to allow for more optimal, extended protection against all bleeding types in patients with severe hemophilia A.
Display omitted
Summary
Due to variability in the one-stage clotting assay, the performance of new factor IX (FIX) products should be assessed in this assay. The objective of this field study was to evaluate the ...accuracy of measuring recombinant FIX Fc fusion protein (rFIXFc) activity in clinical haemostasis laboratories using the one-stage clotting assay. Human haemophilic donor plasma was spiked with rFIXFc or BeneFIX
®
at 0.80, 0.20, or 0.05 IU/ml based on label potency. Laboratories tested blinded samples using their routine one-stage assay and in-house FIX plasma standard. The mean spike recoveries for BeneFIX (n=30 laboratories) were 121 %, 144 %, and 168 % of expected at nominal 0.80, 0.20, and 0.05 IU/ml concentrations, respectively. Corresponding rFIXFc spike recoveries were 88 %, 107 %, and 132 % of expected, respectively. All BeneFIX concentrations were consistently overestimated by most laboratories. rFIXFc activity was reagent-dependent; ellagic acid and silica gave higher values than kaolin, which underestimated rFIXFc. BeneFIX demonstrated significantly reduced chromogenic assay activity relative to one-stage assay results and nominal activity, while rFIXFc activity was close to nominal activity at three concentrations with better dilution linearity than the typical one-stage assay. In conclusion, laboratory- and reagent-specific assay variabilities were revealed, with progressively higher variability at lower FIX concentrations. Non-parallelism against the FIX plasma standard was observed in all one-stage assays with rFIXFc and BeneFIX, leading to significant overestimation of FIX activity at lower levels and generally high inter-laboratory variability. Compared to the accuracy currently achieved in clinical laboratories when measuring other rFIX products, most laboratories measured rFIXFc activity with acceptable accuracy and reliability using routine one-stage assay methods and commercially available plasma standards.
Long-term cures of hemophilia B have been achieved using AAV2 delivering the factor IX gene to the liver of adeno-associated virus (AAV)–naive hemophilic animals. However, the clinical success of ...this approach requires overcoming pre-existing AAV neutralizing antibodies prevalent in humans. To better define the inhibition of neutralizing antibodies on AAV2-mediated liver transduction, we developed an in vivo passive immunity model. SCID mice were first reconstituted to a defined neutralizing titer with pooled plasma-derived human immunoglobulin. AAV2-FIX vectors then were administered to the liver, and the transduction efficiency was measured by plasma FIX levels. Unexpectedly, AAV2 neutralizing titers lower than 1:10 were sufficient to neutralize 4 to 20 × 1012 vg/kg of AAV2 vectors in vivo, a capacity that was underestimated by in vitro neutralizing assays. We also evaluated strategies to evade neutralization, including the use of alternative delivery routes, infusion parameters, empty capsids, and alternative AAV serotypes 6 and 8. The results indicate that low AAV2 neutralizing titers can be inhibitory to the tested human and primate AAV vectors delivered into the circulatory system. Therefore, novel nonprimate AAV vectors or compartmentalized delivery may offer more consistent therapeutic effects in the presence of pre-existing AAV neutralizing antibodies.
Introduction
The one‐stage clotting assay is used to measure factor IX (FIX) activity in patients’ plasma samples and in FIX products for hemophilia treatment. However, the diversity of reagents and ...instruments has resulted in significant FIX assay variability.
Methods
The accuracy of the one‐stage clotting assay to measure recombinant FIX Fc fusion protein (rFIXFc) activity was evaluated by major Japanese hemophilia treatment centers and commercial laboratories that measure factor IX activity for a majority of hemophilia B patients in Japan. Plasma‐derived FIX (pdFIX) and recombinant FIX (rFIX) products were used as comparators. FIX‐deficient plasma was spiked with four levels of FIX products based on label potency and measured under blinded conditions by routine one‐stage clotting assay procedures in 19 participating laboratories. Interlaboratory coefficient of variation and spike recovery were calculated.
Results
Interlaboratory coefficient of variation of rFIXFc was not significantly different from that of rFIX, but appeared larger than that of pdFIX. Mean spike recovery for rFIXFc was generally comparable to rFIX and pdFIX. However, larger discrepancies between pdFIX and rFIX were observed in three of nine laboratories using ellagic acid‐based activated partial thromboplastin time reagents.
Conclusion
Recombinant FIX Fc fusion protein activity was found to be similar to that of rFIX or pdFIX by the one‐stage clotting assay. However, minimizing interlaboratory variability is vital for optimizing future patient care.
Introduction
Monitoring of factor IX (FIX) replacement therapy in haemophilia B relies on accurate coagulation assays. However, considerable interlaboratory variability has been reported for ...one‐stage clotting (OSC) assays. This study aimed to evaluate the real‐world, interlaboratory variability of routine FIX activity assays used in clinical haemostasis laboratories for the measurement of recombinant FIX Fc fusion protein (rFIXFc) activity.
Methods
Human FIX‐depleted plasma was spiked with rFIXFc at 0.80, 0.20 or 0.05 IU/mL based on label potency. Participating laboratories tested samples using their own routine OSC or chromogenic substrate (CS) assay protocols, reagents and FIX plasma standards. Laboratories could perform more than one measurement and method, and were not fully blinded to nominal activity values.
Results
A total of 142 laboratories contributed OSC results from 175 sample kits using 11 different activated partial thromboplastin time (aPTT) reagents. The median recovered FIX activity for the 0.80, 0.20 and 0.05 IU/mL samples was 0.72 IU/mL, 0.21 IU/mL and 0.060 IU/mL, respectively. Across all OSC reagents, interlaboratory variability (% CV) per aPTT reagent ranged from 9.4% to 32.1%, 8.2% to 32.6% and 12.2% to 42.0% at the 0.80, 0.20 and 0.05 IU/mL levels, respectively. CS results showed excellent median recoveries at all nominal levels (87.5% to 115.0%; n = 11) with low interlaboratory variability (CV 3.6% to 15.4%).
Conclusion
This large, real‐world data set indicates that rFIXFc activity in plasma samples can be accurately measured with the majority of routine OSC and CS assay methods. Given the variation in FIX assay procedures between sites, it is important that individual laboratories qualify their in‐house methods for monitoring of rFIXFc activity.
Hemophilia B is an inherited X chromosome-linked disorder characterized by impaired blood clotting owing to the absence of functional coagulation factor IX. Due to the relatively short half-life of ...factor IX, patients with hemophilia B require frequent factor IX infusions to maintain prophylaxis. We have developed a recombinant factor IX (rFIX) fused to the Fc region of IgG (rFIXFc) with an extended half-life in animals and humans.
Procoagulant properties of rFIXFc and rFIX (BENEFIX®) were compared to determine the effect of the Fc region on rFIXFc hemostatic function. Specifically, we assessed rFIXFc activation, intermolecular interactions within the Xase complex, inactivation by antithrombin III (AT) and thrombin generation potential compared with rFIX. We also assessed the acute and prophylactic efficacy profiles of rFIXFc and rFIX in vivo in hemophilia B mouse bleeding models.
The activation by factor XIa or factor VIIa/tissue factor, inhibition by AT, interaction profiles with phospholipids, affinities for factor VIIIa within the context of the Xase complex, and thrombin generation profiles were similar for rFIXFc and rFIX. Xase complexes formed with either molecule exhibited similar kinetic profiles for factor Xa generation. In acute efficacy models, mice infused with rFIXFc or rFIX were equally protected from bleeding. However, in prophylactic efficacy models, protection from bleeding was maintained approximately three times longer in rFIXFc-dosed mice than in those given rFIX; this prolonged efficacy correlates with the previously observed half-life extension. We conclude that rFIXFc retains critical FIX procoagulant attributes and that the extension in rFIXFc half-life translates into prolonged efficacy in hemophilia B mice.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Recombinant factor VIII Fc (rFVIIIFc) is a fusion protein consisting of a single B-domain-deleted (BDD) FVIII linked recombinantly to the Fc domain of human IgG1 to extend half-life. To determine if ...rFVIIIFc could be further improved by maintaining the heavy and light chains within a contiguous single chain (SC), we evaluated the activity and function of SC rFVIIIFc, an isoform that is not processed at residue R1648. SC rFVIIIFc showed equivalent activity in a chromogenic assay compared to rFVIIIFc, but approximately 40% activity by the one-stage clotting assay in the presence of von Willebrand Factor (VWF), with full activity in the absence of VWF. Moreover, SC rFVIIIFc demonstrated markedly delayed thrombin-mediated release from VWF, but an activity similar to that of rFVIIIFc upon activation in FXa generation assays. Therefore, the apparent reduction in specific activity in the aPTT assay appears to be primarily due to delayed release of FVIII from VWF. To assess whether stability and activity of SC rFVIIIFc were affected in vivo, a tail vein transection model in Hemophilia A mice was utilized. The results demonstrated similar pharmacokinetic profiles and comparable efficacy for SC rFVIIIFc and rFVIIIFc. Thus, while the single chain configuration did not promote enhanced half-life, it reduced the rate of release of FVIII from VWF required for activation. This impaired release may underlie the observed reduction in the one-stage clotting assay, but does not appear to affect the physiological activity of SC rFVIIIFc.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
The aim of this study was to compare the hemostatic efficacy of recombinant factor VIII Fc (rFVIIIFc) (Eloctate) and Advate by ex-vivo rotation thromboelastometry (ROTEM) of whole blood and to ...explore potential ROTEM parameters that may be more predictive of a patientʼs bleeding tendency than plasma FVIII activity. Thirteen clinical sites were selected to perform ROTEM on freshly collected blood samples from 44 patients in the phase 3 study for rFVIIIFc, including 16 patients undergoing sequential pharmacokinetic assessment of Advate and rFVIIIFc. Equivalent hemostatic activity was observed for rFVIIIFc and Advate in postinfusion samples, followed by improvements for rFVIIIFc in clotting time, clot formation time and alpha angle (α) for a longer duration than Advate, consistent with the pharmacokinetic improvements reported previously for rFVIIIFc. Our study did not demonstrate a statistical correlation between a patientʼs ROTEM activity at baseline or at trough and the occurrence of spontaneous bleeds while on prophylactic therapy. However, an association was observed between postinfusion clotting time and the occurrence of one or more spontaneous bleeds vs. no bleeds over a follow-up period of 1 year (P = 0.003). How well a patientʼs whole blood clotting deficiency is corrected after a dose of FVIII may be an indicator of subsequent bleeding tendency in patients with otherwise equivalent FVIII peak and trough levels. The technical challenges of standardizing the ROTEM, largely overcome in the current study, may however preclude the use of this method for widespread assessment of global hemostasis unless additional assay controls or normalization procedures prove to be effective.This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0