The most efficient approach to laser interferometric force sensing to date uses monochromatic carrier light with its signal sideband spectrum in a squeezed vacuum state. Quantum decoherence, i.e., ...mixing with an ordinary vacuum state due to optical losses, is the main sensitivity limit. In this Letter, we present both theoretical and experimental evidence that quantum decoherence in high-precision laser interferometric force sensors enhanced with optical cavities and squeezed light injection can be mitigated by a quantum squeeze operation inside the sensor's cavity. Our experiment shows an enhanced measurement sensitivity that is independent of the optical readout loss in a wide range. Our results pave the way for quantum improvements in scenarios where high decoherence previously precluded the use of squeezed light. Our results hold significant potential for advancing the field of quantum sensors and enabling new experimental approaches in high-precision measurement technology.
The aim of this work was to develop a process for the removal of Sn, Sb and As from anode slime out of copper refinery to disburden a subsequent pyrometallurgical processing for precious metals ...refinement. For this reason, a detailed literature survey was conducted, followed by a characterization to find the present compounds/alloys and their morphology. A newly developed process concept for the separate extraction of the afore mentioned three target metals was developed and verified by leaching experiments, combined with thermodynamic calculations on their behavior under varying conditions. In this context, the influence of leaching temperature, alkalinity of leaching solution, and solid-liquid ration were evaluated on the extraction yields of Sn, As, and Sb, as well as how to exploit these findings to obtain separate streams enriched in the respective metals.
nema
In different nonferrous metal-producing industry sectors, the impurity element iron has to be removed from the process solution. Examples for the arising residues are jarosite or goethite ...precipitates from nickel or zinc production but also red mud from aluminum production. Regardless of environmental concerns, the material is landfilled in almost any case, although valuables such as indium, silver, nickel, or zinc are present in considerable amounts. Within the presented research, a low carbon dioxide emitting multi-metal recovery from such iron-containing residues by means of a selective chlorination extraction has been fundamentally evaluated by experiments but also by comprehensive thermodynamic calculations. The paper summarizes the thermodynamic fundamental concept exploited to separate the dominating iron matrix from the valuable elements and shows verification experiments in a lab size of several grams. Through thermodynamic calculations and small-scale experiments with pure metal oxides and sulfates, it has been proven that the metal chlorides AlCl
3
∙6H
2
O, FeCl
3
∙6H
2
O, and MgCl
2
∙6H
2
O are viable and effective reactants for chlorination. In trials with actual industrial iron precipitation residues from the zinc industry, especially, the use of MgCl
2
∙6H
2
O and FeCl
3
∙6H
2
O leads to high extraction rates for the investigated valuable metals Ag, Au, Bi, Cu, In, Pb, Sn, and Zn.
Industrial wastes such as slags, dust, or precipitation residues contain significant amounts of valuable metals like zinc, lead, and copper as well as precious metals like silver and indium. ...Nevertheless, a lot of these waste materials are not recycled, and therefore, many valuable metals end up being sent to landfills. Because of harmful components in the waste, it is often necessary to send it to specialized landfills for hazardous wastes, which leads to environmental problems as well as additional costs. Consequently, the recovery of the valuable metals from the residues represents a sensible task to decrease the negative impact on the environment and to reduce costs for maintaining a landfill. In addition, recycling helps to decrease the dependency from primary resources. The present study deals with the behavior of different metals in a pyro-metallurgical treatment for a mixture of jarosite and electric arc furnace dust with a special focus on indium and silver.
Primary focal dystonia (PFD) is characterised by motor symptoms. Frequent co-occurrence of abnormal mental conditions has been mentioned for decades but is less well defined. In this study, ...prevalence rates of psychiatric disorders, personality disorders and traits in a large cohort of patients with PFD were evaluated.
Prevalence rates of clinical psychiatric diagnoses in 86 PFD patients were compared with a population based sample (n = 3943) using a multiple regression approach. Furthermore, participants were evaluated for personality traits with the 5 Factor Personality Inventory.
Lifetime prevalence for any psychiatric or personality disorder was 70.9%. More specifically, axis I disorders occurred at a 4.5-fold increased chance. Highest odds ratios were found for social phobia (OR 21.6), agoraphobia (OR 16.7) and panic disorder (OR 11.5). Furthermore, an increased prevalence rate of 32.6% for anxious personality disorders comprising obsessive-compulsive (22.1%) and avoidant personality disorders (16.3%) were found. Except for social phobia, psychiatric disorders manifested prior to the occurrence of dystonia symptoms. In the self-rating of personality traits, PFD patients demonstrated pronounced agreeableness, conscientiousness and reduced openness.
Patients with PFD show distinct neuropsychiatric and personality profiles of the anxiety spectrum. PFD should therefore be viewed as a neuropsychiatric disorder rather than a pure movement disorder.
The speed meter concept has been identified as a technique that can potentially provide laser-interferometric measurements at a sensitivity level which surpasses the standard quantum limit (SQL) over ...a broad frequency range. As with other sub-SQL measurement techniques, losses play a central role in speed meter interferometers and they ultimately determine the quantum noise limited sensitivity that can be achieved. So far in the literature, the quantum noise limited sensitivity has only been derived for lossless or lossy cases using certain approximations (for instance that the arm cavity round trip loss is small compared to the arm cavity mirror transmission). In this article we present a generalized, analytical treatment of losses in speed meters that allows accurate calculation of the quantum noise limited sensitivity of Sagnac speed meters with arm cavities. In addition, our analysis allows us to take into account potential imperfections in the interferometer such as an asymmetric beam splitter or differences of the reflectivities of the two arm cavity input mirrors. Finally, we use the examples of the proof-of-concept Sagnac speed meter currently under construction in Glasgow and a potential implementation of a Sagnac speed meter in the Einstein Telescope to illustrate how our findings affect Sagnac speed meters with metre- and kilometre-long baselines.
The Sagnac speed metre topology has been identified as a promising technique to reduce quantum back-action in gravitational-wave interferometers. However, imbalance of the main beamsplitter has been ...shown to increase the coupling of laser noise to the detection port, thus reducing the quantum noise superiority of the speed metre, compared to conventional approaches, in particular at low frequencies. In this paper, we show that by implementing a balanced homodyne readout scheme with a suitable choice of the point from which the local oscillator (LO) is derived, the excess laser noise contribution is partly compensated, and the resulting speed metre can be more sensitive than state-of-the-art position metres. This is achieved by picking-off the LO from either the reflection port of the interferometer or the anti-reflective coating surface of the main beamsplitter. We show that either approach relaxes the relative intensity noise (RIN) requirement of the input laser. For example, for a beam splitter imbalance of 0.1% in the Glasgow speed metre proof of concept experiment, the RIN requirement at frequency of 100 Hz decreases from 4 × 10 − 10 Hz to 4 × 10 − 7 Hz , moving the RIN requirement from a value that is hard to achieve in practice, to one which is routinely obtained.
The timing of growth in seasonal mammals is inextricably linked to food availability. This is exemplified in the Siberian hamster (Phodopus sungorus), which uses the annual cycle of photoperiod to ...optimally programme energy expenditure in anticipation of seasonal fluctuations in food resources. During the autumn, energy expenditure is progressively minimised by physiological adaptations, including a 30% reduction in body mass, comprising a reduction in both fat and lean tissues. However, the mechanistic basis of this adaptation is still unexplained. We hypothesised that growth hormone (GH) was a likely candidate to underpin these reversible changes in body mass. Administration of pasireotide, a long‐acting somatostatin receptor agonist developed for the treatment of acromegaly, to male hamsters under a long‐day (LD) photoperiod produced a body weight loss. This comprised a reduction in lean and fat mass, including kidneys, testes and brown adipose tissue, typically found in short‐day (SD) housed hamsters. Furthermore, when administered to hamsters switched from SD to LD, pasireotide retarded the body weight increase compared to vehicle‐treated hamsters. Pasireotide did not alter photoperiod‐mediated changes in hypothalamic energy balance gene expression but altered the expression of Srif mRNA expression in the periventricular nucleus and Ghrh mRNA expression in the arcuate nucleus consistent with a reduction in GH feedback and concurrent with reduced serum insulin‐like growth factor‐1. Conversely, GH treatment of SD hamsters increased body mass, which included increased mass of liver and kidneys. Together, these data indicate a role for the GH axis in the determination of seasonal body mass of the Siberian hamster.
The second generation of large scale interferometric gravitational wave (GW) detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity ...improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of development are being pursued to reach this goal, focusing both on modifications of the well-established Michelson detector configuration and development of different detector topologies. In this paper, we present the design of the worldʼs first Sagnac speed meter (SSM) interferometer, which is currently being constructed at the University of Glasgow. With this proof-of-principle experiment we aim to demonstrate the theoretically predicted lower quantum noise in a Sagnac interferometer compared to an equivalent Michelson interferometer, to qualify SSM for further research towards an implementation in a future generation large scale GW detector, such as the planned Einstein telescope observatory.
Speedmeters are known to be quantum non-demolition devices and, by potentially providing sensitivity beyond the standard quantum limit, become interesting for third generation gravitational wave ...detectors. Here we introduce a new configuration, the sloshing-Sagnac interferometer, and compare it to the more established ring-Sagnac interferometer. The sloshing-Sagnac interferometer is designed to provide improved quantum noise limited sensitivity and lower coating thermal noise than standard position meter interferometers employed in current gravitational wave detectors. We compare the quantum noise limited sensitivity of the ring-Sagnac and the sloshing-Sagnac interferometers, in the frequency range, from 5 Hz to 100 Hz, where they provide the greatest potential benefit. We evaluate the improvement in terms of the unweighted noise reduction below the standard quantum limit, and by finding the range up to which binary black hole inspirals may be observed. The sloshing-Sagnac was found to give approximately similar or better sensitivity than the ring-Sagnac in all cases. We also show that by eliminating the requirement for maximally-reflecting cavity end mirrors with correspondingly-thick multi-layer coatings, coating noise can be reduced by a factor of approximately 2.2 compared to conventional interferometers.