Membrane-potential dynamics mediate bacterial electrical signaling at both intra- and intercellular levels. Membrane potential is also central to cellular proliferation. It is unclear whether the ...cellular response to external electrical stimuli is influenced by the cellular proliferative capacity. A new strategy enabling electrical stimulation of bacteria with simultaneous monitoring of single-cell membrane-potential dynamics would allow bridging this knowledge gap and further extend electrophysiological studies into the field of microbiology. Here we report that an identical electrical stimulus can cause opposite polarization dynamics depending on cellular proliferation capacity. This was demonstrated using two model organisms, namely Bacillus subtilis and Escherichia coli, and by developing an apparatus enabling exogenous electrical stimulation and single-cell time-lapse microscopy. Using this bespoke apparatus, we show that a 2.5-second electrical stimulation causes hyperpolarization in unperturbed cells. Measurements of intracellular K⁺ and the deletion of the K⁺ channel suggested that the hyperpolarization response is caused by the K⁺ efflux through the channel. When cells are preexposed to 400 ± 8 nm wavelength light, the same electrical stimulation depolarizes cells instead of causing hyperpolarization. A mathematical model extended from the FitzHugh–Nagumo neuron model suggested that the opposite response dynamics are due to the shift in resting membrane potential. As predicted by the model, electrical stimulation only induced depolarization when cells are treated with antibiotics, protonophore, or alcohol. Therefore, electrically induced membrane-potential dynamics offer a reliable approach for rapid detection of proliferative bacteria and determination of their sensitivity to anti-microbial agents at the single-cell level.
Summary Objective To estimate the reliability and measurement error of performance-based tests of physical function recommended by the Osteoarthritis Research Society International in people with hip ...and/or knee osteoarthritis. Design Prospective repeated measures between independent raters within a session and within-rater over a week interval. Relative reliability was estimated for 51 people with hip and/or knee osteoarthritis (mean age 64.5 years, SD 6.21 years; 47% females; 36 (70%) primary knee OA) on the 30s Chair Stand Test (30sCST), 40m Fast Paced Walk Test (40mFPWT), 11-Stair Climb Test (11-step SCT), Timed Up and Go (TUG), Six Minute Walk Test (6MWT), 10m Fast Paced Walk Test (10mFPWT) and 20s Stair Climb Test (20sSCT) using intra-class correlation coefficients (ICC). Absolute reliability was calculated using standard error of measurement (SEM) and minimal detectable change (MDC). Results Measurement error was acceptable (SEM <10%) for all tests. Between rater reliability was: optimal (ICC > 0.9, lower 1-sided 95% CI > 0.7) for the 40mFPWT, 6MWT and 10mFPWT; sufficient (ICC >0.8, lower 1-sided 95% CI >0.7) for 30sCST, 20sSCT; unacceptable (lower 1-side 95%CI <0.7) for 11-step SCT and TUG. Within-rater reliability was optimal for 40mFPWT, and 6MWT; sufficient for 30sCST and 10mFPWT and unacceptable for 11-step SCT, TUG and 20sSCT. Conclusions The 30sCST, 40mFPWT, 6MWT and 10mFPWT, demonstrated, at minimum, acceptable levels of both between and within rater reliability and measurement error. All tests demonstrated sufficiently small measurement error indicating they are adequate for measuring change over time in individuals with knee/hip OA.
Summary Objectives To recommend a consensus-derived set of performance-based tests of physical function for use in people diagnosed with hip or knee osteoarthritis (OA) or following joint ...replacement. Methods An international, multidisciplinary expert advisory group was established to guide the study. Potential tests for consideration in the recommended set were identified via a survey of selected experts and through a systematic review of the measurement properties for performance-based tests. A multi-phase, consensus-based approach was used to prioritize and select performance-based tests by applying decision analysis methodology (1000Minds software) via online decision surveys. The recommended tests were chosen based on available measurement-property evidence, feasibility of the tests, scoring methods and expert consensus. Results Consensus incorporated the opinions of 138 experienced clinicians and researchers from 16 countries. The five tests recommended by the advisory group and endorsed by Osteoarthritis Research Society International (OARSI) were the 30-s chair-stand test, 40 m fast-paced walk test, a stair-climb test, timed up-and-go test and 6-min walk test. The first three were recommended as the minimal core set of performance-based tests for hip or knee OA. Conclusion The OARSI recommended set of performance-based tests of physical function represents the tests of typical activities relevant to individuals diagnosed with hip or knee OA and following joint replacements. These tests are complementary to patient-reported measures and are recommended as prospective outcome measures in future OA research and to assist decision-making in clinical practice. Further research should be directed to expanding the measurement-property evidence of the recommended tests.
Literature review, expert panel, and a workshop during the "VIII International Forum on Primary Care Research on Low Back Pain" (Amsterdam, June 2006).
To develop practical guidance regarding the ...minimal important change (MIC) on frequently used measures of pain and functional status for low back pain.
Empirical studies have tried to determine meaningful changes for back pain, using different methodologies. This has led to confusion about what change is clinically important for commonly used back pain outcome measures.
This study covered the Visual Analogue Scale (0-100) and the Numerical Rating Scale (0-10) for pain and for function, the Roland Disability Questionnaire (0-24), the Oswestry Disability Index (0-100), and the Quebec Back Pain Disability Questionnaire (0-100). The literature was reviewed for empirical evidence. Additionally, experts and participants of the VIII International Forum on Primary Care Research on Low Back Pain were consulted to develop international consensus on clinical interpretation.
There was wide variation in study design and the methods used to estimate MICs, and in values found for MIC, where MIC is the improvement in clinical status of an individual patient. However, after discussion among experts and workshop participants a reasonable consensus was achieved. Proposed MIC values are: 15 for the Visual Analogue Scale, 2 for the Numerical Rating Scale, 5 for the Roland Disability Questionnaire, 10 for the Oswestry Disability Index, and 20 for the QBDQ. When the baseline score is taken into account, a 30% improvement was considered a useful threshold for identifying clinically meaningful improvement on each of these measures.
For a range of commonly used back pain outcome measures, a 30% change from baseline may be considered clinically meaningful improvement when comparing before and after measures for individual patients. It is hoped that these proposals facilitate the use of these measures in clinical practice and the comparability of future studies. The proposed MIC values are not the final answer but offer a common starting point for future research.
Summary Objectives No clinical prediction rules were found for estimating the likelihood of developing incident radiographic tibiofemoral osteoarthritis (OA) with rapid progression. Such a tool would ...enhance prognostic capability for clinicians and researchers. Design We used two longitudinal datasets to independently derive (Multicenter Osteoarthritis Study) and validate (Osteoarthritis Initiative) a prognostic clinical prediction rule for estimating the probability of incident rapidly progressing radiographic knee OA in the following 4–5 years. Eligible subjects had at least one knee with a Kellgren and Lawrence (K&L) graded tibiofemoral joint of 0 or 1. Several potential risk factors were examined including obesity, age, knee alignment, frequent knee symptoms, contralateral knee OA and knee injury history. Multiple logistic regression was used to identify significant predictors and area under the receiver operating characteristic curve (AUC) was used to assess discrimination. Results A total of 1690 subjects participated in the derivation and 2422 subjects participated in the validation of the clinical prediction rule. The multivariable model displayed good discrimination with AUC of 0.79 in the derivation dataset and 0.81 in the validation dataset. Conclusions Persons with contralateral knee OA, a baseline index knee OA grade of 1, higher body mass index (BMI) and higher baseline WOMAC total scores were more likely to develop K&L grade of 3 or 4 within 5 years. Frequent knee symptoms at baseline were not a significant predictor. The prediction rule and nomogram can assist clinicians in estimating the probability of rapidly progressing radiographic knee OA and the nomogram can assist researchers conducting epidemiologic studies and clinical trials.
Choosing an adequate measurement instrument depends on the proposed use of the instrument, the concept to be measured, the measurement properties (e.g. internal consistency, reproducibility, content ...and construct validity, responsiveness, and interpretability), the requirements, the burden for subjects, and costs of the available instruments. As far as measurement properties are concerned, there are no sufficiently specific standards for the evaluation of measurement properties of instruments to measure health status, and also no explicit criteria for what constitutes good measurement properties. In this paper we describe the protocol for the COSMIN study, the objective of which is to develop a checklist that contains COnsensus-based Standards for the selection of health Measurement INstruments, including explicit criteria for satisfying these standards. We will focus on evaluative health related patient-reported outcomes (HR-PROs), i.e. patient-reported health measurement instruments used in a longitudinal design as an outcome measure, excluding health care related PROs, such as satisfaction with care or adherence. The COSMIN standards will be made available in the form of an easily applicable checklist.
An international Delphi study will be performed to reach consensus on which and how measurement properties should be assessed, and on criteria for good measurement properties. Two sources of input will be used for the Delphi study: (1) a systematic review of properties, standards and criteria of measurement properties found in systematic reviews of measurement instruments, and (2) an additional literature search of methodological articles presenting a comprehensive checklist of standards and criteria. The Delphi study will consist of four (written) Delphi rounds, with approximately 30 expert panel members with different backgrounds in clinical medicine, biostatistics, psychology, and epidemiology. The final checklist will subsequently be field-tested by assessing the inter-rater reproducibility of the checklist.
Since the study will mainly be anonymous, problems that are commonly encountered in face-to-face group meetings, such as the dominance of certain persons in the communication process, will be avoided. By performing a Delphi study and involving many experts, the likelihood that the checklist will have sufficient credibility to be accepted and implemented will increase.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
This study examined whether a perioperative regimen of pregabalin added to celecoxib improved pain scores and functional outcomes postdischarge up to 3 months after total hip arthroplasty (primary ...outcome) and acute postoperative pain and adverse effects (secondary outcomes).
One hundred and eighty-four patients were enrolled in a randomized, double-blind, placebo-controlled study. Two hours before receiving a spinal anaesthetic and undergoing surgery, patients received celecoxib 400 mg p.o. and were randomly assigned to receive either pregabalin 150 mg p.o. or placebo p.o. After surgery, patients received pregabalin 75 mg or placebo twice daily in hospital and for 7 days after discharge. Patients also received celecoxib 200 mg every 12 h for 72 h and morphine i.v. patient-controlled analgesia for 24 h. Pain and function were assessed at baseline, 6 weeks, and 3 months after surgery.
There was no difference between groups in physical function or incidence and intensity of chronic pain 3 months after total hip arthroplasty. The pregabalin group used less morphine mean (sd): 39.85 (28.1) mg than the placebo group 54.01 (31.2) mg in the first 24 h after surgery (P<0.01). Pain scores were significantly lower in the pregabalin group vs the placebo group on days 1–7 after hospital discharge, and the pregabalin group required less adjunctive opioid medication (Percocet) 1 week after hospital discharge (P<0.05).
Perioperative administration of pregabalin did not improve pain or physical function at 6 weeks or 3 months after total hip arthroplasty. Perioperative administration of pregabalin decreased opioid consumption in hospital and reduced daily pain scores and adjunct opioid consumption for 1 week after discharge.
Biomechanical factors are important treatment targets in knee osteoarthritis. The knee adduction (KAM) and flexion (KFM) moments, quadriceps strength and power, load frequency, and body mass index ...(BMI) all have the potential to affect knee articular cartilage integrity by modulating forces across the joint. To identify clinically meaningful change, however, these measurements must be reliable and sensitive to change. This study estimated relative and absolute test–retest reliabilities over long periods of biomechanical risk factors for knee osteoarthritis progression.
Data from a longitudinal, observational study were analyzed for knee osteoarthritis patients with data at baseline, 6-month and 24-month follow-ups. Gait kinematics and kinetics, quadriceps strength and power, daily load frequency and BMI were collected. Relative and absolute test–retest reliabilities of these measures were estimated using intraclass correlation coefficients (ICCs) and standard errors of measurement (SEMs), respectively. Minimal detectable change at the 95% confidence level (MDC95) was also calculated.
Data from 46 participants 36 women; age 61.0 (6.6) years were included. Good-to-excellent relative reliabilities (ICC ≥ 0.80) indicated that KAM peak and impulse, quadriceps strength and power, and BMI had a strong ability to discriminate amongst participants. Absolute reliabilities were high for quadriceps strength and BMI, which demonstrated reasonable within-participant variability (SEMs ≤ 11% of the mean). The MDC95 values supported use of clinical interventions effective in reducing BMI and KAM, and increasing quadriceps strength.
These data are useful in interpreting findings from interventional or longitudinal investigations by determining whether observed changes are beyond measurement error and interpretable as true change.
Response to mechanical force is a well characterised phenomenon in eukaryotic organisms, helping to organise multicellular structures. Mechanotactic responses have only rarely been observed in ...prokaryotic taxa. This work reports on a morphological change due to variations in applied force and surface structure by Bacillus mycoides Flügge. B. mycoides is a ubiquitous soil organism well known among microbiologists for its characteristic spreading colony morphology. An apparent mechanotactic response is elicited by physical deformation of the gel media on which B.mycoides is growing, including applied forces of compression or tension. Variations in the surface such as curvature produced by casting the agar gel in the presence of curved objects also elicited the change. The morphological change in B.mycoides colonies associated with the application of force manifests as a pattern of parallel rhizoid filaments perpendicular to compressing force and parallel to stretching force in the agar medium. The phenomenon is most clearly demonstrated by reversible changes in the orientation of B. mycoides filaments during time-lapse microscopy.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
This study was designed to determine whether a 4 day perioperative regimen of gabapentin added to celecoxib improves in-hospital rehabilitation and physical function on postoperative day 4 and 6 ...weeks and 3 months after total knee arthroplasty (TKA).
After Research Ethics Board approval and informed consent, 212 patients were enrolled in a randomized, double-blinded, placebo-controlled study. Two hours before surgery, patients received celecoxib 400 mg p.o. and were randomly assigned to receive either gabapentin 600 mg or placebo p.o. Two hours later, patients received femoral, sciatic nerve blocks, and spinal anaesthesia. After operation, patients received gabapentin 200 mg or placebo three times per day (TID) for 4 days. All patients also received celecoxib 200 mg q12 h for 72 h and i.v. patient-controlled analgesia for 24 h. Pain and function were assessed at baseline, during hospitalization, on postoperative day 4 (POD4), and 6 weeks and 3 months after surgery.
The gabapentin group used less morphine in the first 24 h after surgery G=38.3 (29.5 mg), P=48.2 (29.4 mg) (P<0.0125) and had increased knee range of motion compared with the placebo group in-hospital (P<0.05). There were no differences between groups in favour of the gabapentin group for pain or physical function on POD 4 95% confidence interval (CI): pain: −1.4, 0.5; function: −6.3, 2.0, 6 weeks (95% CI: pain: 0.1, 1.9; function: −0.2, 6.5) or 3 months (95% CI: pain: −0.2, 1.7; function: −2.2, 4.3) after TKA.
In the context of celecoxib, spinal anaesthesia, femoral and sciatic nerve blocks, a dose of gabapentin 600 mg before operation followed by 4 days of gabapentin 200 mg TID decreased postoperative analgesic requirements and improved knee range of motion after TKA. Gabapentin provided no improvement in pain or physical function on POD4 and 6 weeks or 3 months after surgery.