X-Arapuca long term test Andreossi, V.; Balmforth, Z.; Bergamini Machado, A.A. ...
Journal of instrumentation,
02/2024, Letnik:
19, Številka:
2
Journal Article
Recenzirano
Odprti dostop
Abstract The photon detection system of the DUNE experiment is based on the X-ARAPUCA light trap. The basic elements of the X-ARAPUCA are the dichroic filters coated with wavelength shifter ...(para-Therphenyl), a waveshifting plate and an array of SiPMs which detects the trapped photons. A small scale prototype of the X-ARAPUCA has been installed in liquid argon in a dedicated facility at INFN-Napoli and exposed to alpha particles from a source. In order to test the stability of the overall device response the X-ARAPUCA was kept for 10 days in continuously purified liquid argon. The performed tests allowed for a preliminary estimation of the X-ARAPUCA absolute photon detection efficiency.
Abstract
Current generation of detectors using noble gases in liquid phase for direct dark matter search and neutrino physics need large area photosensors. Silicon based photo-detectors are ...innovative light collecting devices and represent a successful technology in these research fields. The DarkSide collaboration started a dedicated development and customization of SiPM technology for its specific needs resulting in the design, production and assembly of large surface modules of 20 × 20 cm
2
named Photo Detection Unit for the DarkSide-20k experiment. Production of a large number of such devices, as needed to cover about 20 m
2
of active surface inside the DarkSide-20k detector, requires a robust testing and validation process. In order to match this requirement a dedicated test facility for photosensors was designed and commissioned at INFN-Naples laboratory. The first commissioning test was successfully performed in 2021. Since then a number of testing campaigns were performed. Detailed description of the facility is reported as well as results of some tests.
Abstract
In this work we will document the design and the performances of a SiPM-based photo-detector with a surface area of 100 cm
2
conceived to operate as a replacement for PMTs. The signals from ...94 SiPMs are summed up to produce an aggregated output that exhibits in liquid nitrogen a dark count rate (DCR) lower than 100 cps over the entire surface, a signal to noise ratio better than 13, and a timing resolution better than 5.5 ns. The module feeds about 360 mW at 5 V with a dynamic range in excess of 500 photo-electrons on a 100 Ω differential line. The unit can also operate at room temperature, at the cost of an increase of DCR to 10
8
cps.
Abstract Liquid Argon (LAr) Time Projection Chambers (TPC) operating in double-phase can detect the nuclear recoils (NR) possibly caused by the elastic scattering of WIMP dark matter particles via ...light signals from both scintillation and ionization processes. In the scenario of a low-mass WIMP (< 2 GeV/c 2 ), the energy range for the NRs would be below 20 keV, thus making it crucial to characterize the ionization response in LAr TPCs as the lone available detection channel at such low energy. The Recoil Directionality (ReD) project, within the Global Argon Dark Matter Collaboration, aims to measure the ionization yield of a LAr TPC in the recoil energy range of 2–5 keV. The measurement was performed in winter 2023 at the INFN Sezione of Catania and the analysis is ongoing.
Rare event search experiments, such as those searching for dark matter and observations of neutrinoless double beta decay, require ultra low levels of radioactive background for unmistakable ...identification. In order to reduce the radioactive background of detectors used in these types of event searches, low background photosensors are required, as the physical size of these detectors become increasing larger, and hence the number of such photosensors used also increases rapidly. Considering that most dark matter and neutrinoless double beta decay experiments are turning towards using noble liquids as the target choice, liquid xenon and liquid argon for instance, photosensors that can work well at cryogenic temperatures are required, 165 K and 87 K for liquid xenon and liquid argon, respectively. The Silicon Geiger Hybrid Tube (SiGHT) is a novel photosensor designed specifically for use in ultra low background experiments operating at cryogenic temperatures. It is based on the proven photocathode plus silicon photomultiplier (SiPM) hybrid technology and consists of very few other, but also ultra radio-pure, materials like fused silica and silicon for the SiPM. The introduction of the SiGHT concept, as well as a feasibility study for its production, is reported in this paper.
Plasma Level’s of Neuregulin-1 in Healthy People Zhbanov, K. A.; Shchendrygina, A. A.; Zheleznykh, E. A. ...
Rat͡s︡ionalʹnai͡a︡ farmakoterapii͡a︡ v kardiologii,
01/2021, Letnik:
17, Številka:
6
Journal Article
Recenzirano
Odprti dostop
Aim
. To determine the median levels of neuregulin-1 (NRG-1; endothelium-derived growth factor and the natural agonist of the ERBB3 and ERBB4 receptors) NRG-1 in healthy volunteers and to study the ...associations of NRG-1 levels with gender and age.
Material and Methods
. Ninety seven healthy participants were enrolled (median age of 44 32-54, men 45 men 46.4%). The following age groups were identified: 20-29 y.о. (n=20, men – 50.0%), 30-39 y.о. (n=21, men – 52.4%), 40-49 y.о. (n=22, men – 45.5%), 50-59 y.о. (n=22, men – 36.4%); 60-69 y.о. (n=12, men – 50.0%). Peripheral blood samples were collected at the time of enrolment, standard laboratory tests were performed, and NRG-1 levels were determined in the plasma samples by ELISA.
Results
. In the cohort of 97 healthy participants the median value of NRG-1 was 0.3 0.121-2.24 ng/ml. NRG-1 levels did not differ significantly between men and women (p=0.145), indicating that NRG-1 levels are not influenced by gender. The levels of NRG-1 were similar in the different age groups: age 20-29 years=0.26 0.17-0.37 ng/ml; age 30-39=0.24 0.1-0.39 ng/ml; age 40-49=0.31 0.19-1.15 ng/ml; age 50-59=0.37 0.19-1.0 ng/ml; age 60-69=0.4 0.13-0.81 ng/ml. Correlation analysis between NRG-1 levels and route blood measurements (haemoglobin, lipids, glucose, creatinine, and uretic acid) did not show significant associations.
Conclusions
. In this study, the median value of NRG-1 plasma levels were determined. The results of the study show that age and gender had no influence on NRG-1 values.
The rate of neutrino-electron elastic scattering interactions from 862 keV Be7 solar neutrinos in Borexino is determined to be 46.0±1.5(stat)-1.6+1.5(syst)counts/(day*100ton). This corresponds to a ...νe-equivalent Be7 solar neutrino flux of (3.10±0.15)×109cm-2s-1 and, under the assumption of νe transition to other active neutrino flavours, yields an electron neutrino survival probability of 0.51±0.07 at 862 keV. The no flavor change hypothesis is ruled out at 5.0σ. A global solar neutrino analysis with free fluxes determines Φpp=6.06-0.06+0.02×1010cm-2s-1 and ΦCNO<1.3×109cm-2s-1 (95% C.L.). These results significantly improve the precision with which the Mikheyev-Smirnov-Wolfenstein large mixing angle neutrino oscillation model is experimentally tested at low energy.
A liquid argon time projection chamber, constructed for the Argon Response to Ionization and Scintillation (ARIS) experiment, is exposed to the highly collimated and quasimonoenergetic LICORNE ...neutron beam at the Institut de Physique Nucléaire d’Orsay (IPNO) in order to study the scintillation response to nuclear and electronic recoils. An array of liquid scintillator detectors, arranged around the apparatus, tag scattered neutrons and select nuclear recoil energies in the 7, 120 keV energy range. The relative scintillation efficiency of nuclear recoils is measured to high precision at null field, and the ion-electron recombination probability is extracted for a range of applied electric fields. Single-scattered Compton electrons, produced by gammas emitted from the deexcitation of Li*7 in coincidence with the beam pulse, along with calibration gamma sources, are used to extract the recombination probability as a function of energy and electron drift field. The ARIS results are compared with three recombination probability parametrizations (Thomas-Imel, Doke-Birks, and PARIS), allowing for the definition of a fully comprehensive model of the liquid argon response to nuclear and electronic recoils down to the few-keV range. The constraints provided by ARIS to the liquid argon response at low energy allow the reduction of systematics affecting the sensitivity of dark matter search experiments based on liquid argon.
Abstract
Detectors for direct dark matter search using noble gases in the liquid phase as a detection medium need to be coupled to liquefaction, purification and recirculation systems. A dedicated ...cryogenic system has been assembled and operated at the INFN-Naples cryogenic laboratory with the aim to liquefy and purify the argon used as an active target in liquid argon detectors to study the scintillation and ionization signals detected by large SiPM arrays. The cryogenic system is mainly composed of a double wall cryostat hosting the detector, a purification stage to reduce the impurities below one part per billion level, a condenser to liquefy the argon, and a recirculation gas panel connected to the cryostat equipped with a custom gas pump. The main features of the cryogenic system are reported as well as the performance, long term operation and stability in terms of the most relevant thermodynamic parameters.