A
bstract
The Compact Linear Collider (CLIC) is a proposed future high-luminosity linear electron-positron collider operating at three energy stages, with nominal centre-of-mass energies
s
= 380 GeV, ...1
.
5 TeV, and 3 TeV. Its aim is to explore the energy frontier, providing sensitivity to physics beyond the Standard Model (BSM) and precision measurements of Standard Model processes with an emphasis on Higgs boson and top-quark physics. The opportunities for top-quark physics at CLIC are discussed in this paper. The initial stage of operation focuses on top-quark pair production measurements, as well as the search for rare flavour-changing neutral current (FCNC) top-quark decays. It also includes a top-quark pair production threshold scan around 350 GeV which provides a precise measurement of the top-quark mass in a well-defined theoretical framework. At the higher-energy stages, studies are made of top-quark pairs produced in association with other particles. A study of t
̄
tH production including the extraction of the top Yukawa coupling is presented as well as a study of vector boson fusion (VBF) production, which gives direct access to high-energy electroweak interactions. Operation above 1 TeV leads to more highly collimated jet environments where dedicated methods are used to analyse the jet constituents. These techniques enable studies of the top-quark pair production, and hence the sensitivity to BSM physics, to be extended to higher energies. This paper also includes phenomenological interpretations that may be performed using the results from the extensive top-quark physics programme at CLIC.
The discovery of topological order has revised the understanding of quantum matter and provided the theoretical foundation for many quantum error–correcting codes. Realizing topologically ordered ...states has proven to be challenging in both condensed matter and synthetic quantum systems. We prepared the ground state of the toric code Hamiltonian using an efficient quantum circuit on a superconducting quantum processor. We measured a topological entanglement entropy near the expected value of –ln2 and simulated anyon interferometry to extract the braiding statistics of the emergent excitations. Furthermore, we investigated key aspects of the surface code, including logical state injection and the decay of the nonlocal order parameter. Our results demonstrate the potential for quantum processors to provide insights into topological quantum matter and quantum error correction.
The Compact Linear Collider (CLIC) is an option for a future
e
+
e
-
collider operating at centre-of-mass energies up to
3
TeV
, providing sensitivity to a wide range of new physics phenomena and ...precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages:
s
=
350
GeV
, 1.4 and
3
TeV
. The initial stage of operation allows the study of Higgs boson production in Higgsstrahlung (
e
+
e
-
→
Z
H
) and
W
W
-fusion (
e
+
e
-
→
H
ν
e
ν
¯
e
), resulting in precise measurements of the production cross sections, the Higgs total decay width
Γ
H
, and model-independent determinations of the Higgs couplings. Operation at
s
>
1
TeV
provides high-statistics samples of Higgs bosons produced through
W
W
-fusion, enabling tight constraints on the Higgs boson couplings. Studies of the rarer processes
e
+
e
-
→
t
t
¯
H
and
e
+
e
-
→
H
H
ν
e
ν
¯
e
allow measurements of the top Yukawa coupling and the Higgs boson self-coupling. This paper presents detailed studies of the precision achievable with Higgs measurements at CLIC and describes the interpretation of these measurements in a global fit.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
A promising approach to study condensed-matter systems is to simulate them on an engineered quantum platform
. However, the accuracy needed to outperform classical methods has not been achieved so ...far. Here, using 18 superconducting qubits, we provide an experimental blueprint for an accurate condensed-matter simulator and demonstrate how to investigate fundamental electronic properties. We benchmark the underlying method by reconstructing the single-particle band structure of a one-dimensional wire. We demonstrate nearly complete mitigation of decoherence and readout errors, and measure the energy eigenvalues of this wire with an error of approximately 0.01 rad, whereas typical energy scales are of the order of 1 rad. Insight into the fidelity of this algorithm is gained by highlighting the robust properties of a Fourier transform, including the ability to resolve eigenenergies with a statistical uncertainty of 10
rad. We also synthesize magnetic flux and disordered local potentials, which are two key tenets of a condensed-matter system. When sweeping the magnetic flux we observe avoided level crossings in the spectrum, providing a detailed fingerprint of the spatial distribution of local disorder. By combining these methods we reconstruct electronic properties of the eigenstates, observing persistent currents and a strong suppression of conductance with added disorder. Our work describes an accurate method for quantum simulation
and paves the way to study new quantum materials with superconducting qubits.
First measurements of beam backgrounds at SuperKEKB Lewis, P.M.; Jaegle, I.; Nakayama, H. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
01/2019, Letnik:
914
Journal Article
Recenzirano
Odprti dostop
The high design luminosity of the SuperKEKB electron–positron collider is expected to result in challenging levels of beam-induced backgrounds in the interaction region. Properly simulating and ...mitigating these backgrounds is critical to the success of the Belle II experiment. We report on measurements performed with a suite of dedicated beam background detectors, collectively known as BEAST II, during the so-called Phase 1 commissioning run of SuperKEKB in 2016, which involved operation of both the high energy ring (HER) of 7 GeV electrons as well as the low energy ring (LER) of 4 GeV positrons. We describe the BEAST II detector systems, the simulation of beam backgrounds, and the measurements performed. The measurements include standard ones of dose rates versus accelerator conditions, and more novel investigations, such as bunch-by-bunch measurements of injection backgrounds and measurements sensitive to the energy spectrum and angular distribution of fast neutrons. We observe beam–gas, Touschek, beam–dust, and injection backgrounds. As there is no final focus of the beams in Phase 1, we do not observe significant synchrotron radiation, as expected. Measured LER beam–gas backgrounds and Touschek backgrounds in both rings are slightly elevated, on average three times larger than the levels predicted by simulation. HER beam–gas backgrounds are on average two orders of magnitude larger than predicted. Systematic uncertainties and channel-to-channel variations are large, so that these excesses constitute only 1–2 sigma level effects. Neutron background rates are higher than predicted and should be studied further. We will measure the remaining beam background processes, due to colliding beams, in the imminent commissioning Phase 2. These backgrounds are expected to be the most critical for Belle II, to the point of necessitating replacement of detector components during the Phase 3 (full-luminosity) operation of SuperKEB.
Some T cell hybridomas, upon activation via the TCR, rapidly undergo cell death. In this paper, we demonstrate that this activation-induced cell death (AICD) is accompanied by morphologic changes ...seen at the electron and light microscopy levels. The most striking changes are an extensive condensation of the chromatin and formation of membrane blebs. In addition to the morphologic changes, a significant portion of genomic DNA is broken at an interval of approximately 200 bp, producing a ladder of oligonucleosome-sized fragments after gel electrophoresis. Taken together, these observations indicate that AICD proceeds via apoptosis, or programmed cell death. This is additionally supported by the observation that AICD-associated phenomena are at least partially inhibited by cycloheximide or actinomycin D. Curiously, AICD and its associated DNA fragmentation are completely inhibited by aurintricarboxylic acid, a known nuclease inhibitor. The possible relationship between AICD in vitro, and the negative selection process (wherein selection may proceed via AICD of developing, autoreactive thymocytes) is discussed.
Turán
12
proved that for almost all pairs of partitions of an integer, the proportion of common parts is very high, that is greater than
1
2
-
ε
with
ε
>
0
arbitrarily small. In this paper we prove ...that this surprising phenomenon persists when we look only at the summands in a fixed arithmetic progression.
We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60GeV/c. ...Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of 1×1cm2 and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010–11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on Geant4, which utilise different electromagnetic and hadronic physics lists.
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future linear collider experiments. A prototype of 21.5 X0 depth and 180×180mm2 transverse ...dimensions was constructed, consisting of 2160 individually read out 10×45×3mm3 scintillator strips. This prototype was tested using electrons of 2–32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1%, and the intrinsic energy resolution was determined to be (12.5±0.1(stat.)±0.4(syst.))%∕EGeV⊕(1.2±0.1(stat.)−0.7+0.6(syst.))%, where the uncertainties correspond to statistical and systematic sources, respectively.