Abstract Objectives The purpose of this analysis was to assess 5-year outcomes of transcatheter aortic valve implantation (TAVI) using the current technology of the self-expanding CoreValve ...prosthesis (Medtronic Inc., Minneapolis, Minnesota). Background There is a paucity of evidence on long-term durability of currently available transcatheter heart valves. Methods Starting in June 2007, all consecutive patients with severe aortic stenosis undergoing TAVI with the third-generation 18-F CoreValve device in 8 Italian centers were prospectively included in the ClinicalService Project. For the purposes of this study, we included only consecutive patients with 5-year follow-up data available (n = 353) treated from June 2007 to August 2009. All outcomes were reported according to VARC (Valve Academic Research Consortium)-1 criteria. Results All-cause mortality rates at 1, 2, 3, 4, and 5 years were 21%, 29%, 38%, 48%, and 55.0%, respectively. Cardiovascular mortality rates at 1, 2, 3, 4, and 5 years were 10%, 14%, 19%, 23%, and 28.0%, respectively. The overall neurological event rate at 5 years was 7.5%, of which more than two-thirds occurred early after the procedure. During follow-up, there were 241 rehospitalizations for cardiovascular reasons in 164 (46%) patients. Among all rehospitalizations, acute heart failure was the most frequently reported (42.7%), followed by requirement of permanent pacemaker implantation (17.4%). On echocardiography, mean transaortic gradients decreased from 55.6 ± 16.8 mm Hg (pre-TAVI) to 12.8 ± 10.9 mm Hg (5-year post-TAVI) (p < 0.001). Late prosthesis failure occurred in 5 cases (1.4%); among these, redo TAVI was successfully carried out in 2 patients (0.6%) presenting with symptomatic prosthesis restenosis. The remaining 3 cases of prosthesis failure did not undergo further invasive interventions. Ten patients (2.8%) showed late mild stenosis with a mean transaortic gradient ranging from 20 to 40 mm Hg. No other cases of structural or nonstructural valvular deterioration were observed. Valve thrombosis or late valve embolization were not reported. Conclusions TAVI with the currently adopted CoreValve generation was associated with sustained clinical outcomes up to 5-year follow-up, with a low rate (1.4%) of significant prosthetic valve degeneration. The procedure appears to be an adequate and lasting resolution of aortic stenosis in selected high-risk patients.
Abstract Background Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV). Objectives ...This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV. Methods We retrospectively collected baseline characteristics, procedural data, and clinical follow-up findings from 12 centers in Europe and Canada that had performed TAV-in-BAV. Results A total of 139 patients underwent TAV-in-BAV with the balloon-expandable transcatheter heart valve (THV) (n = 48) or self-expandable THV (n = 91) systems. Patient mean age and Society of Thoracic Surgeons predicted risk of mortality scores were 78.0 ± 8.9 years and 4.9 ± 3.4%, respectively. BAV stenosis occurred in 65.5%, regurgitation in 0.7%, and mixed disease in 33.8% of patients. Incidence of type 0 BAV was 26.7%; type 1 BAV was 68.3%; and type 2 BAV was 5.0%. Multislice computed tomography (MSCT)-based TAV sizing was used in 63.5% of patients (77.1% balloon-expandable THV vs. 56.0% self-expandable THV, p = 0.02). Procedural mortality was 3.6%, with TAV embolization in 2.2% and conversion to surgery in 2.2%. The mean aortic gradient decreased from 48.7 ± 16.5 mm Hg to 11.4 ± 9.9 mm Hg (p < 0.0001). Post-implantation aortic regurgitation (AR) grade ≥2 occurred in 28.4% (19.6% balloon-expandable THV vs. 32.2% self-expandable THV, p = 0.11) but was prevalent in only 17.4% when MSCT-based TAV sizing was performed (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio OR: 0.19, 95% confidence intervals CI: 0.08 to 0.45; p < 0.0001). Thirty-day device safety, success, and efficacy were noted in 79.1%, 89.9%, and 84.9% of patients, respectively. One-year mortality was 17.5%. Major vascular complications were associated with increased 1-year mortality (OR: 5.66, 95% CI: 1.21 to 26.43; p = 0.03). Conclusions TAV-in-BAV is feasible with encouraging short- and intermediate-term clinical outcomes. Importantly, a high incidence of post-implantation AR is observed, which appears to be mitigated by MSCT-based TAV sizing. Given the suboptimal echocardiographic results, further study is required to evaluate long-term efficacy.
Abstract Background Few studies have evaluated the clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS). Particularly, limited data ...exist comparing the results of TAVR with new-generation devices versus early-generation devices. Objectives This study sought to evaluate the clinical outcomes of TAVR for bicuspid AS with early- and new-generation devices. Methods The Bicuspid TAVR Registry is an international multicenter study enrolling consecutive patients with bicuspid AS undergoing TAVR between April 2005 and May 2015. Results Of 301 patients, 199 patients (71.1%) were treated with early-generation devices (Sapien XT Edwards Lifesciences Corporation, Irvine, California: n = 87; CoreValve Medtronic, Minneapolis, Minnesota: n = 112) and 102 with new-generation devices (Sapien 3 Edwards Lifesciences Corporation: n = 91; Lotus Boston Scientific Corporation, Marlborough, Massachusetts: n = 11). The mean Society of Thoracic Surgeons score was 4.7 ± 5.2 without significant differences between groups (4.6 ± 5.1 vs. 4.9 ± 5.4; p = 0.57). Overall, all-cause mortality rates were 4.3% at 30 days and 14.4% at 1 year. Moderate or severe paravalvular leak was absent and significantly less frequent with new-generation compared to early-generation devices (0.0% vs. 8.5%; p = 0.002), which resulted in a higher device success rate (92.2% vs. 80.9%; p = 0.01). There were no differences between early- and new-generation devices in stroke (2.5% vs. 2.0%; p > 0.99), life-threatening bleeding (3.5% vs. 2.9%; p > 0.99), major vascular complication (4.5% vs. 2.9%; p = 0.76), stage 2 to 3 acute kidney injury (2.5% vs. 2.9%; p > 0.99), early safety endpoints (15.1% vs. 10.8%; p = 0.30), and 30-day all-cause mortality (4.5% vs. 3.9%; p > 0.99). Conclusions The clinical outcomes of TAVR in patients with bicuspid AS were favorable. New-generation devices were associated with less paravalvular leak and, hence, a higher device success rate than early-generation devices. (The Bicuspid Aortic Stenosis Following Transcatheter Aortic Valve Replacement Registry Bicuspid TAVR; NCT02394184 )
Abstract Objectives This study sought to evaluate transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) aortic stenosis (AS), with a particular emphasis on TAVR-directed ...bicuspid aortic valve imaging (BAVi) of morphological classification. Background TAVR has been used to treat BAV-AS but with heterogeneous outcomes and uncertainty regarding the relevance of morphology. Methods In 14 centers in the United States, Canada, Europe, and Asia, 130 BAV-AS patients underwent TAVR. Baseline cardiac computed tomography (CT) was analyzed by a dedicated Corelab. Outcomes were assessed in line with Valve Academic Research Consortium criteria. Results Bicommissural BAV (vs. tricommissural) accounted for 68.9% of those treated in North America, 88.9% in Europe, and 95.5% in Asia (p = 0.003). For bicommissural bicuspids, non-raphe type (vs. raphe type) BAV accounted for 11.9% of those treated in North America, 9.4% in Europe, and 61.9% in Asia (p < 0.001). Overall rates of 30-day mortality (3.8%) and cerebrovascular events (3.2%) were favorable and similar among anatomical subsets. The rate of new permanent pacemaker insertion was high (26.2%) and similar between balloon-expandable (BE) and self-expanding (SE) designs (BE: 25.5% vs. SE: 26.9%; p = 0.83); there was a trend to greater permanent pacemaker insertion in BE TAVR in the presence of coronary cusp fusion BAV morphology. Paravalvular aortic regurgitation (PAR) ≥ moderate was 18.1% overall but lower at 11.5% in those with pre-procedural CT. In the absence of pre-procedural CT, there was an excess of PAR in BE TAVR that was not the case in those with a pre-procedural CT; SE TAVR required more post-dilation. Predictors of PAR included intercommissural distance for bicommissural bicuspids (odd ratio OR: 1.37; 95% confidence interval CI: 1.02 to 1.84; p = 0.036) and lack of a baseline CT for annular measurement (OR: 3.03; 95% CI: 1.20 to 7.69; p = 0.018). Conclusions In this multicenter study, TAVR achieved favorable outcomes in patients with pre-procedural CT, with the exception of high permanent pacemaker rates for all devices and shapes.
Incomplete stent apposition (ISA) is characterized by the lack of contact of at least 1 stent strut with the vessel wall in a segment not overlying a side branch; it is more commonly found in ...drug-eluting stents than bare-metal stents. The accurate diagnosis of ISA, initially only possible with intravascular ultrasound, can currently be performed with higher accuracy by optical coherence tomography, which also enables strut-level assessment due to its higher axial resolution. Different circumstances related both to the index procedure and to vascular healing might influence ISA occurrence. Although several histopathology and clinical studies linked ISA to stent thrombosis, potential selection bias precluded definitive conclusions. Initial studies usually performed single time point assessments comparing overall ISA percentage and magnitude in different groups (i.e., stent type), thus hampering a comprehensive understanding of its relationship with vascular healing. Serial intravascular imaging studies that evaluated vascular response heterogeneity recently helped fill this gap. Some particular clinical scenarios such as acute coronary syndromes, bifurcations, tapered vessels, overlapping stents, and chronic total occlusions might predispose to ISA. Interventional cardiologists should be committed to optimal stent choices and techniques of implantation and use intravascular imaging guidance when appropriate to aim at minimizing acute ISA. In addition, the active search for new stent platforms that could accommodate vessel remodeling over time (i.e., self-expandable stents) and for new polymers and/or eluting drugs that could induce less inflammation (hence, less positive remodeling) could ultimately reduce the occurrence of ISA and its potentially harmful consequences.
Dual antiplatelet therapy (DAPT) with clopidogrel and aspirin is a widely accepted strategy in patients undergoing transcatheter aortic valve implantation (TAVI), but this approach is not evidence ...based. The goal of the present study was to determine whether DAPT in patients undergoing TAVI is associated with improved outcomes compared to aspirin alone. From May 2009 to August 2010, consecutive patients were randomized to receive a 300-mg loading dose of clopidogrel on the day before TAVI followed by a 3-month maintenance daily dose of 75 mg plus aspirin 100 mg lifelong (DAPT group) or aspirin 100 mg alone (ASA group). The primary end point was the composite of major adverse cardiac and cerebrovascular events, defined as death from any cause, myocardial infarction, major stroke, urgent or emergency conversion to surgery, or life-threatening bleeding. The cumulative incidence of major adverse cardiac and cerebrovascular events at 30 days and 6 months was 14% and 16%, respectively. No significant differences between the DAPT and ASA groups were noted at both 30 days (13% vs 15%, p = 0.71) and 6 months (18% vs 15%; p = 0.85). In conclusion, the strategy of adding clopidogrel to aspirin for 3 months after TAVI was not found to be superior to aspirin alone. These results must be confirmed in a larger randomized trial.
A few studies recently reported controversial results with transfemoral transcatheter aortic valve replacement (TF-TAVR) versus transapical transcatheter aortic valve replacement (TA-TAVR), often ...without adequate adjusted analysis for baseline differences. Data on patients who underwent TF-TAVR and TA-TAVR from the Observational Study of Effectiveness of avR–tavI procedures for severe Aortic stenosis Treatment study were analyzed with propensity score 1-to-1 matching. From a cohort of 1,654 patients (1,419 patients underwent TF-TAVR and 235 patients underwent TA-TAVR), propensity score matching resulted in 199 pairs of patients with similar operative risk (EuroSCORE II: TF-TAVR 8.1 ± 7.1% vs TA-TAVR, 8.4 ± 7.3%, p = 0.713). Thirty-day mortality was 8.0% after TA-TAVR and 4.0% after TF-TAVR (p = 0.102). Postoperative rates of stroke (TA-TAVR, 2.0% vs TF-TAVR 1.0%, p = 0.414), cardiac tamponade (TA-TAVR, 4.1% vs TF-TAVR 1.5%, p = 0.131), permanent pacemaker implantation (TA-TAVR, 8.7% vs TF-TAVR 13.3%, p = 0.414), and infection (TA-TAVR, 6.7% vs TF-TAVR 3.6%, p = 0.180) were similar in the study groups but with an overall trend in favor of TF-TAVR. Higher rates of major vascular damage (7.2% vs 1.0%, p = 0.003) and moderate-to-severe paravalvular regurgitation (7.8% vs 5.2%, p = 0.008) were observed after TF-TAVR. On the contrary, TA-TAVR was associated with higher rates of red blood cell transfusion (50.0% vs 30.4%, p = 0.0002) and acute kidney injury (stages 1 to 3: 44.4% vs 21.9%, p <0.0001) compared with TF-TAVR. Three-year survival rate was 69.1% after TF-TAVR and 57.0% after TA-TAVR (p = 0.006), whereas freedom from major adverse cardiovascular and cerebrovascular events was 61.9% after TF-TAVR and 50.4% after TA-TAVR (p = 0.011). In conclusion, TF-TAVR seems to be associated with significantly higher early and intermediate survival compared with TA-TAVR. The transfemoral approach, whenever feasible, should be considered the route of choice for TAVR.
Risk stratification tools used in patients with severe aortic stenosis have been mostly derived from surgical series. Although specific predictors of early mortality with transcatheter aortic valve ...replacement (TAVR) have been identified, the prognostic impact of their combination is unexplored. We sought to develop a simple score, using preprocedural variables, for prediction of 30-day mortality after TAVR. A total of 1,878 patients from a national multicenter registry who underwent TAVR were randomly assigned in a 2:1 manner to development and validation data sets. Baseline characteristics of the 1,256 patients in the development data set were considered as candidate univariate predictors of 30-day mortality. A bootstrap multivariate logistic regression process was used to select correlates of 30-day mortality that were subsequently weighted and integrated into a scoring system. Seven variables were weighted proportionally to their respective odds ratios for 30-day mortality (glomerular filtration rate <45 ml/min 6 points, critical preoperative state 5 points, New York Heart Association class IV 4 points, pulmonary hypertension 4 points, diabetes mellitus 4 points, previous balloon aortic valvuloplasty 3 points, and left ventricular ejection fraction <40% 3 points). The model showed good discrimination in both the development and validation data sets (C statistics 0.73 and 0.71, respectively). Compared with the logistic European System for Cardiac Operative Risk Evaluation in the validation data set, the model showed better discrimination (C statistic 0.71 vs 0.66), goodness of fit (Hosmer-Lemeshow p value 0.81 vs 0.00), and global accuracy (Brier score 0.054 vs 0.073). In conclusion, the risk of 30-day mortality after TAVR may be estimated by combining 7 baseline clinical variables into a simple risk scoring system.
The aim of this study was to report on the 30-day and 1-year outcomes of percutaneous mitral valve repair with the MitraClip technique in patients with grade ≥3+ mitral regurgitation (MR) at high ...risk for conventional surgical therapy enrolled in the prospective Getting Reduction of Mitral Insufficiency by Percutaneous Clip Implantation (GRASP) registry. Acute device success was defined as residual MR ≤2+ after clip implantation. The primary safety end point was the rate of major adverse events at 30 days. The primary efficacy end point was freedom from death, surgery for mitral valve dysfunction, or grade ≥3+ MR at 30 days and 1 year. A total of 117 patients were treated. Eighty-nine patients (76%) presented with functional MR and 28 patients (24%) with organic MR. Acute device success was observed in all patients. Device implantation time significantly diminished with experience and varied significantly between cases with 1 versus ≥2 clips. No procedural mortality was recorded. Major adverse events occurred in 4 patients at 30 days (4.3%). Deterioration to MR ≥3+ was recorded in 25% of patients with degenerative MR and 7% of those with functional MR at 1 year. No surgery for mitral valve dysfunction occurred within 1 year. Freedom from death, surgery for mitral valve dysfunction, or grade ≥3+ MR was 96.4% and 75.8% at 30 days and 1 year, respectively. No significant differences were noted in the primary efficacy end point between patients with degenerative MR and those with functional MR. In conclusion, percutaneous mitral valve repair with the MitraClip technique was shown to be safe and reasonably effective in 117 patients from a real-world setting.
Background There is limited information on the long-term outcomes and prognostic clinical predictors after edge-to-edge transcatheter mitral valve repair with the MitraClip system. Methods ...Consecutive patients with mitral regurgitation (MR) undergoing MitraClip therapy between October 2008 and November 2013 in 4 Italian centers were analyzed. The primary end point of interest was all-cause death. The secondary end point was the composite of all-cause death or rehospitalization for heart failure. Results A total of 304 patients were included, of which 79% had functional MR and 17% were in New York Heart Association functional class IV. Acute procedural success was obtained in 92% of cases, with no intraprocedural death. The cumulative incidences of all-cause death were 3.4%, 10.8%, and 18.6% at 30 days, 1 year, and 2 years, respectively. The corresponding incidences of the secondary end point were 4.4%, 22.0%, and 39.7%, respectively. In the Cox multivariate model, New York Heart Association functional class IV at baseline and ischemic MR etiology were found to significantly and independently predict both the primary and the secondary end point. A baseline, left ventricular end-systolic volume >110 mL was found to be an independent predictor of the secondary endpoint. Acute procedural success was independently associated with a lower risk of all-cause death and the combination of all-cause death or rehospitalization for heart failure at long-term follow-up. Conclusions In a cohort of patients undergoing MitraClip therapy, those presenting at baseline with ischemic functional etiology, severely dilated ventricles, or advanced heart failure and those undergoing unsuccessful procedures carried the worst prognosis.