We demonstrate efficient transverse compression of a 12.5 MeV/c muon beam stopped in a helium gas target featuring a vertical density gradient and crossed electric and magnetic fields. The muon stop ...distribution extending vertically over 14 mm was reduced to a 0.25 mm size (rms) within 3.5 μs. The simulation including cross sections for low-energy μ+-He elastic and charge exchange (μ+↔ muonium) collisions describes the measurements well. By combining the transverse compression stage with a previously demonstrated longitudinal compression stage, we can improve the phase space density of a μ+ beam by a factor of 1010 with 10−3 efficiency.
Efficient conversion of a standard positive muon beam into a high-quality slow muon beam is shown to be achievable by compression of a muon swarm stopped in an extended gas volume. The stopped swarm ...can be squeezed into a mm-size swarm flow that can be extracted into vacuum through a small opening in the stop target walls. Novel techniques of swarm compression are considered. In particular, a density gradient in crossed electric and magnetic fields is used.
A novel device to compress the phase space of a muon beam by a factor of
10
10
with a
10
-
3
efficiency is under development. A surface muon beam is stopped in a helium gas target consisting of ...several compression stages, wherein strong electric and magnetic fields are applied. The spatial extent of the stopped muon swarm is decreased by means of these fields until muons with eV energy are extracted into vacuum through a small orifice. It was observed that a 20 cm long muon stop distribution can be compressed in the longitudinal direction to a sub-mm extent within
2
μ
s
. Additionally, a drift perpendicular to the magnetic field of the compressed low-energy muon swarm was successfully demonstrated, paving the way towards extraction from the gas and re-acceleration of the muons.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
Precision spectroscopy of light muonic atoms provides unique information about the atomic and nuclear structure of these systems and thus represents a way to access fundamental interactions, ...properties and constants. One application comprises the determination of absolute nuclear charge radii with unprecedented accuracy from measurements of the 2S - 2P Lamb shift. Here, we review recent results of nuclear charge radii extracted from muonic hydrogen and helium spectroscopy and present experiment proposals to access light muonic atoms with Z ≥ 3. In addition, our approaches towards a precise measurement of the Zemach radii in muonic hydrogen (μp) and helium (μ3He+) are discussed. These results will provide new tests of bound-state quantum-electrodynamics in hydrogen-like systems and can be used as benchmarks for nuclear structure theories.
E_cient conversion of a standard muon beam into a high quality slow muon beam by using the muonium ionization method is shown to be achievable with a new kind of converter. It consists of a ...superfluid helium layer from which muonium atoms escape because of their negative a_nity. Application to pulsed muon beams in an optimized target configuration leads to a reduction of the necessary VUV laser energy by a factor of 100. The resulting muon beam has more than 4 orders of magnitude better phase space quality than what is obtained today with the silica powder converter. When using the superfluid helium converter in association with high quality DC muon beams in development at the Paul Scherrer Institute, it should be possible to use intense continuous lasers for ionization and obtain ultra-high quality continuous muon beams with precise timing of the muon arrival.
We demonstrate a stationary helium gas density gradient which is needed for a proposed novel low-energy μ+ beam line. In a closed system with constant pressure the corresponding density gradient is ...only a function of the temperature. In a neutron radiography experiment two gas cells with different geometries were filled with 3He gas at constant pressures of about 10mbar. Temperatures in the range from 6K to 40K were applied and density distributions with a maximum to minimum density ratio of larger than 3 were realized. The distribution was investigated employing the strongly neutron absorbing isotope 3He. A simple one-dimensional approach derived from Fourier׳s law describes the obtained gas density with a deviation <2%.
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from ...scattering and regular hydrogen spectroscopy.
Is the proton radius a player in the redefinition of the International System of Units? Nez, F.; Antognini, A.; Amaro, F. D. ...
Philosophical transactions - Royal Society. Mathematical, Physical and engineering sciences/Philosophical transactions - Royal Society. Mathematical, physical and engineering sciences,
10/2011, Letnik:
369, Številka:
1953
Journal Article
Recenzirano
Odprti dostop
It is now recognized that the International System of Units (SI units) will be redefined in terms of fundamental constants, even if the date when this will occur is still under debate. Actually, the ...best estimate of fundamental constant values is given by a least-squares adjustment, carried out under the auspices of the Committee on Data for Science and Technology (CODATA) Task Group on Fundamental Constants. This adjustment provides a significant measure of the correctness and overall consistency of the basic theories and experimental methods of physics using the values of the constants obtained from widely differing experiments. The physical theories that underlie this adjustment are assumed to be valid, such as quantum electrodynamics (QED). Testing QED, one of the most precise theories is the aim of many accurate experiments. The calculations and the corresponding experiments can be carried out either on a boundless system, such as the electron magnetic moment anomaly, or on a bound system, such as atomic hydrogen. The value of fundamental constants can be deduced from the comparison of theory and experiment. For example, using QED calculations, the value of the fine structure constant given by the CODATA is mainly inferred from the measurement of the electron magnetic moment anomaly carried out by Gabrielse's group. (Hanneke et al. 2008 Phys. Rev. Lett. 100, 120801) The value of the Rydberg constant is known from two-photon spectroscopy of hydrogen combined with accurate theoretical quantities. The Rydberg constant, determined by the comparison of theory and experiment using atomic hydrogen, is known with a relative uncertainty of 6.6×10−12. It is one of the most accurate fundamental constants to date. A careful analysis shows that knowledge of the electrical size of the proton is nowadays a limitation in this comparison. The aim of muonic hydrogen spectroscopy was to obtain an accurate value of the proton charge radius. However, the value deduced from this experiment contradicts other less accurate determinations. This problem is known as the proton radius puzzle. This new determination of the proton radius may affect the value of the Rydberg constant . This constant is related to many fundamental constants; in particular, links the two possible ways proposed for the redefinition of the kilogram, the Avogadro constant NA and the Planck constant h. However, the current relative uncertainty on the experimental determinations of NA or h is three orders of magnitude larger than the 'possible' shift of the Rydberg constant, which may be shown by the new value of the size of the proton radius determined from muonic hydrogen. The proton radius puzzle will not interfere in the redefinition of the kilogram. After a short introduction to the properties of the proton, we will describe the muonic hydrogen experiment. There is intense theoretical activity as a result of our observation. A brief summary of possible theoretical explanations at the date of writing of the paper will be given. The contribution of the proton radius puzzle to the redefinition of SI-based units will then be examined.