Objective To assess the effects of vitamin D supplementation during pregnancy on obstetric outcomes and birth variables. Design Systematic review and meta-analysis of randomized controlled trials ...(RCTs). Setting Not applicable. Patient(s) Pregnant women and neonates. Intervention(s) PubMed and 5 other research databases were searched through March 2014 for RCTs evaluating vitamin D supplementation ± calcium/vitamins/ferrous sulfate vs. a control (placebo or active) during pregnancy. Main Outcome Measure(s) Measures were: circulating 25-hydroxyvitamin D 25(OH)D levels, preeclampsia, gestational diabetes mellitus (GDM), small for gestational age (SGA), low birth weight, preterm birth, birth weight, birth length, cesarean section. Mantel-Haenszel fixed-effects models were used, owing to expected scarcity of outcomes. Effects were reported as relative risks and their 95% confidence intervals (CIs). Result(s) Thirteen RCTs (n = 2,299) were selected. Circulating 25(OH)D levels were significantly higher at term, compared with the control group (mean difference: 66.5 nmol/L, 95% CI 66.2–66.7). Birth weight and birth length were significantly greater for neonates in the vitamin D group; mean difference: 107.6 g (95% CI 59.9–155.3 g) and 0.3 cm (95% CI 0.10–0.41 cm), respectively. Incidence of preeclampsia, GDM, SGA, low birth weight, preterm birth, and cesarean section were not influenced by vitamin D supplementation. Across RCTs, the doses and types of vitamin D supplements, gestational age at first administration, and outcomes were heterogeneous. Conclusion(s) Vitamin D supplementation during pregnancy was associated with increased circulating 25(OH)D levels, birth weight, and birth length, and was not associated with other maternal and neonatal outcomes. Larger, better-designed RCTs evaluating clinically relevant outcomes are necessary to reach a definitive conclusion.
Antibiotic exposure is the most important risk factor for Clostridium difficile infection (CDI). Most evaluations of antimicrobial risk factors have been conducted in healthcare settings. The ...objective of this meta-analysis was to evaluate the association between antibiotic exposure and community-associated CDI (CA-CDI) (i.e. symptom onset in the community with no healthcare facility admission within 12 weeks) and to determine the classes of antibiotics posing the greatest risk.
We searched four electronic databases for subject headings and text words related to CA-CDI and antibiotics. Studies that investigated the risk of CA-CDI associated with antibiotic usage were considered eligible. Data from the identified studies were combined using a random-effects model and ORs were calculated.
Of 910 citations identified, eight studies (n = 30 184 patients) met our inclusion criteria. Antibiotic exposure was associated with an increased risk of CA-CDI (OR 6.91, 95% CI 4.17-11.44, I(2) = 95%). The risk was greatest with clindamycin (OR 20.43, 95% CI 8.50-49.09) followed by fluoroquinolones (OR 5.65, 95% CI 4.38-7.28), cephalosporins (OR 4.47, 95% CI 1.60-12.50), penicillins (OR 3.25, 95% CI 1.89-5.57), macrolides (OR 2.55, 95% CI 1.91-3.39) and sulphonamides/trimethoprim (OR 1.84, 95% CI 1.48-2.29). Tetracyclines were not associated with an increased CDI risk (OR 0.91, 95% CI 0.57-1.45).
Antibiotic exposure was an important risk factor for CA-CDI, but the risk was different amongst different antibiotic classes. The risk was greatest with clindamycin followed by fluoroquinolones and cephalosporins, whereas tetracyclines were not associated with an increased risk.
An estimated 20-30% of patients with primary Clostridium difficile infection (CDI) develop recurrent CDI (rCDI) within 2 weeks of completion of therapy. While the actual mechanism of recurrence ...remains unknown, a variety of risk factors have been suggested and studied. The aim of this systematic review and meta-analysis was to evaluate current evidence on the risk factors for rCDI.
We searched MEDLINE and 5 other databases for subject headings and text related to rCDI. All studies investigating risk factors of rCDI in a multivariate model were eligible. Information on study design, patient population, and assessed risk factors were collected. Data were combined using a random-effects model and pooled relative risk ratios (RRs) were calculated.
A total of 33 studies (n=18,530) met the inclusion criteria. The most frequent independent risk factors associated with rCDI were age≥65 years (risk ratio RR, 1.63; 95% confidence interval CI, 1.24-2.14; P=.0005), additional antibiotics during follow-up (RR, 1.76; 95% CI, 1.52-2.05; P<.00001), use of proton-pump inhibitors (PPIs) (RR, 1.58; 95% CI, 1.13-2.21; P=.008), and renal insufficiency (RR, 1.59; 95% CI, 1.14-2.23; P=.007). The risk was also greater in patients previously on fluoroquinolones (RR, 1.42; 95% CI, 1.28-1.57; P<.00001).
Multiple risk factors are associated with the development of rCDI. Identification of modifiable risk factors and judicious use of antibiotics and PPI can play an important role in the prevention of rCDI.
Efficacy and safety of treatments for hospitalized COVID-19 are uncertain. We systematically reviewed efficacy and safety of remdesivir for the treatment of COVID-19.
Studies evaluating remdesivir in ...adults with hospitalized COVID-19 were searched in several engines until August 21, 2020. Primary outcomes included all-cause mortality, clinical improvement or recovery, need for invasive ventilation, and serious adverse events (SAEs). Inverse variance random effects meta-analyses were performed.
We included four randomized controlled trials (RCTs) (n = 2296) two vs. placebo (n = 1299) and two comparing 5-day vs. 10-day regimens (n = 997), and two case series (n = 88). Studies used intravenous remdesivir 200mg the first day and 100mg for four or nine more days. One RCT (n = 236) was stopped early due to AEs; the other three RCTs reported outcomes between 11 and 15 days. Time to recovery was decreased by 4 days with remdesivir vs. placebo in one RCT (n = 1063), and by 0.8 days with 5-days vs. 10-days of therapy in another RCT (n = 397). Clinical improvement was better for 5-days regimen vs. standard of care in one RCT (n = 600). Remdesivir did not decrease all-cause mortality (RR 0.71, 95%CI 0.39 to 1.28, I2 = 43%) and need for invasive ventilation (RR 0.57, 95%CI 0.23 to 1.42, I2 = 60%) vs. placebo at 14 days but had fewer SAEs; 5-day decreased need for invasive ventilation and SAEs vs. 10-day in one RCT (n = 397). No differences in all-cause mortality or SAEs were seen among 5-day, 10-day and standard of care. There were some concerns of bias to high risk of bias in RCTs. Heterogeneity between studies could be due to different severities of disease, days of therapy before outcome determination, and how ordinal data was analyzed.
There is paucity of adequately powered and fully reported RCTs evaluating effects of remdesivir in hospitalized COVID-19 patients. Until stronger evidence emerges, we cannot conclude that remdesivir is efficacious for treating COVID-19.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
IMPORTANCE: Contamination of the skin and clothing of health care personnel during removal of personal protective equipment (PPE) contributes to dissemination of pathogens and places personnel at ...risk for infection. OBJECTIVES: To determine the frequency and sites of contamination on the skin and clothing of personnel during PPE removal and to evaluate the effect of an intervention on the frequency of contamination. DESIGN, SETTING, AND PARTICIPANTS: We conducted a point-prevalence study and quasi-experimental intervention from October 28, 2014, through March 31, 2015. Data analysis began November 17, 2014, and ended April 21, 2015. Participants included a convenience sample of health care personnel from 4 Northeast Ohio hospitals who conducted simulations of contaminated PPE removal using fluorescent lotion and a cohort of health care personnel from 7 study units in 1 medical center that participated in a quasi-experimental intervention that included education and practice in removal of contaminated PPE with immediate visual feedback based on fluorescent lotion contamination of skin and clothing. MAIN OUTCOMES AND MEASURES: The primary outcomes were the frequency and sites of contamination on skin and clothing of personnel after removal of contaminated gloves or gowns at baseline vs after the intervention. A secondary end point focused on the correlation between contamination of skin with fluorescent lotion and bacteriophage MS2, a nonpathogenic, nonenveloped virus. RESULTS: Of 435 glove and gown removal simulations, contamination of skin or clothing with fluorescent lotion occurred in 200 (46.0%), with a similar frequency of contamination among the 4 hospitals (range, 42.5%-50.3%). Contamination occurred more frequently during removal of contaminated gloves than gowns (52.9% vs 37.8%, P = .002) and when lapses in technique were observed vs not observed (70.3% vs 30.0%, P < .001). The intervention resulted in a reduction in skin and clothing contamination during glove and gown removal (60.0% before the intervention vs 18.9% after, P < .001) that was sustained after 1 and 3 months (12.0% at both time points, P < .001 compared with before the intervention). During simulations of contaminated glove removal, the frequency of skin contamination was similar with fluorescent lotion and bacteriophage MS2 (58.0% vs 52.0%, P = .45). CONCLUSIONS AND RELEVANCE: Contamination of the skin and clothing of health care personnel occurs frequently during removal of contaminated gloves or gowns. Educational interventions that include practice with immediate visual feedback on skin and clothing contamination can significantly reduce the risk of contamination during removal of PPE.
Abstract Aim It has been suggested that chronic hyperinsulinemia from insulin resistance is involved in the etiology of endometrial cancer (EC). We performed a systematic review and meta-analysis to ...assess whether insulin resistance is associated with the risk of EC. Methods We searched PubMed-Medline, Embase, Scopus, and Web of Science for articles published from database inception through 30th September 2014. We included all observational studies evaluating components defining insulin resistance in women with and without EC. Quality of the included studies was assessed by Newcastle–Ottawa scale. Random-effects models and inverse variance method were used to meta-analyze the association between insulin resistance components and EC. Results Twenty-five studies satisfied our inclusion criteria. Fasting insulin levels (13 studies, n = 4088) were higher in women with EC (mean difference MD 33.94 pmol/L, 95% confidence interval CI 15.04–52.85, p = 0.0004). No differences were seen in postmenopausal versus pre- and postmenopausal subgroup analysis. Similarly, non-fasting/fasting C-peptide levels (five studies, n = 1938) were also higher in women with EC (MD 0.14 nmol/L, 95% CI 0.08–0.21, p < 0.00001). Homeostatic model assessment - insulin resistance (HOMA-IR) values (six studies, n = 1859) in EC patients were significantly higher than in women without EC (MD 1.13, 95% CI 0.20–2.06, p = 0.02). There was moderate-to-high heterogeneity among the included studies. Conclusion Currently available epidemiologic evidence is suggestive of significantly higher risk of EC in women with high fasting insulin, non-fasting/fasting C-peptide and HOMA-IR values.
Background & Aims In the past decade, there has been a growing epidemic of Clostridium difficile infection (CDI). During this time, use of proton pump inhibitors (PPIs) has increased exponentially. ...We evaluated the association between PPI therapy and the risk of CDI by performing a meta-analysis. Methods We searched MEDLINE and 4 other databases for subject headings and text words related to CDI and PPI in articles published from 1990 to 2010. All observational studies that investigated the risk of CDI associated with PPI therapy and used CDI as an end point were considered eligible. Two investigators screened articles independently for inclusion criteria, data extraction, and quality assessment; disagreements were resolved based on consensus with a third investigator. Data were combined by means of a random-effects model and odds ratios were calculated. Subgroup and sensitivity analyses were performed based on study design and antibiotic use. Results Thirty studies (25 case-control and 5 cohort) reported in 29 articles met the inclusion criteria (n = 202,965). PPI therapy increased the risk for CDI (odds ratio, 2.15, 95% confidence interval, 1.81–2.55), but there was significant heterogeneity in results among studies ( P < .00001). This association remained after subgroup and sensitivity analyses, although significant heterogeneity persisted among studies. Conclusions PPI therapy is associated with a 2-fold increase in risk for CDI. Because of the observational nature of the analyzed studies, we were not able to study the causes of this association. Further studies are needed to determine the mechanisms by which PPI therapy might increase risk for CDI.
A major challenge for malaria is the lack of tools for accurate and timely diagnosis in the field which are critical for case management and surveillance. Microscopy along with rapid diagnostic tests ...are the current mainstay for malaria diagnosis in most endemic regions. However, these methods present several limitations. This study assessed the accuracy of Gazelle, a novel rapid malaria diagnostic device, from samples collected from the Peruvian Amazon between 2019 and 2020. Diagnostic accuracy was compared against microscopy and two rapid diagnostic tests (SD Bioline and BinaxNOW) using 18ssr nested-PCR as reference test. In addition, a real-time PCR assay (PET-PCR) was used for parasite quantification. Out of 217 febrile patients enrolled and tested, 180 specimens (85
P
.
vivax
and 95 negatives) were included in the final analysis. Using nested-PCR as the gold standard, the sensitivity and specificity of Gazelle was 88.2% and 97.9%, respectively. Using a cutoff of 200 parasites/μl, Gazelle’s sensitivity for samples with more than 200 p/uL was 98.67% (95%CI: 92.79% to 99.97%) whereas the sensitivity for samples lower than 200 p/uL (n = 10) was 12.5% (95%CI: 0.32% to 52.65%). Gazelle’s sensitivity and specificity were statistically similar to microscopy (sensitivity = 91.8, specificity = 100%, p = 0.983) and higher than both SD Bioline (sensitivity = 82.4, specificity = 100%, p = 0.016) and BinaxNOW (sensitivity = 71.8%, specificity = 97.9%, p = 0.002). The diagnostic accuracy of Gazelle for malaria detection in
P
.
vivax
infections was comparable to light microscopy and superior to both RDTs even in the presence of low parasitemia infections. The performance of Gazelle makes it a valuable tool for malaria diagnosis and active case detection that can be utilized in different malaria-endemic regions.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
OBJECTIVE To determine the effectiveness of a pulsed xenon ultraviolet (PX-UV) disinfection device for reduction in recovery of healthcare-associated pathogens. SETTING Two acute-care hospitals. ...METHODS We examined the effectiveness of PX-UV for killing of Clostridium difficile spores, methicillin-resistant Staphylococcus aureus (MRSA), and vancomycin-resistant Enterococcus (VRE) on glass carriers and evaluated the impact of pathogen concentration, distance from the device, organic load, and shading from the direct field of radiation on killing efficacy. We compared the effectiveness of PX-UV and ultraviolet-C (UV-C) irradiation, each delivered for 10 minutes at 4 feet. In hospital rooms, the frequency of native pathogen contamination on high-touch surfaces was assessed before and after 10 minutes of PX-UV irradiation. RESULTS On carriers, irradiation delivered for 10 minutes at 4 feet from the PX-UV device reduced recovery of C. difficile spores, MRSA, and VRE by 0.55±0.34, 1.85±0.49, and 0.6±0.25 log10 colony-forming units (CFU)/cm2, respectively. Increasing distance from the PX-UV device dramatically reduced killing efficacy, whereas pathogen concentration, organic load, and shading did not. Continuous UV-C achieved significantly greater log10CFU reductions than PX-UV irradiation on glass carriers. On frequently touched surfaces, PX-UV significantly reduced the frequency of positive C. difficile, VRE, and MRSA culture results. CONCLUSIONS The PX-UV device reduced recovery of MRSA, C. difficile, and VRE on glass carriers and on frequently touched surfaces in hospital rooms with a 10-minute UV exposure time. PX-UV was not more effective than continuous UV-C in reducing pathogen recovery on glass slides, suggesting that both forms of UV have some effectiveness at relatively short exposure times.
This study was undertaken to evaluate the association between components defining insulin resistance and breast cancer in women.
We conducted a systematic review of four databases (PubMed-Medline, ...EMBASE, Web of Science, and Scopus) for observational studies evaluating components defining insulin resistance in women with and without breast cancer. A meta-analysis of the association between insulin resistance components and breast cancer was performed using random effects models.
Twenty-two studies (n = 33,405) were selected. Fasting insulin levels were not different between women with and without breast cancer (standardized mean difference, SMD -0.03, 95%CI -0.32 to 0.27; p = 0.9). Similarly, non-fasting/fasting C-peptide levels were not different between the two groups (mean difference, MD 0.07, -0.21 to 0.34; p = 0.6). Using individual odds ratios (ORs) adjusted at least for age, there was no higher risk of breast cancer when upper quartiles were compared with the lowest quartile (Q1) of fasting insulin levels (OR Q2 vs. Q1 0.96, 0.71 to 1.28; OR Q3 vs. Q1 1.22, 0.91 to 1.64; OR Q4 vs. Q1 0.98, 0.70 to 1.38). Likewise, there were no differences for quartiles of non-fasting/fasting C-peptide levels (OR Q2 vs. Q1 1.12, 0.91 to 1.37; OR Q3 vs. Q1 1.20, 0.91 to 1.59; OR Q4 vs. Q1 1.40, 1.03 to 1.92). Homeostatic model assessment (HOMA-IR) levels in breast cancer patients were significantly higher than in people without breast cancer (MD 0.22, 0.13 to 0.31, p<0.00001).
Higher levels of fasting insulin or non-fasting/fasting C-peptide are not associated with breast cancer in women. HOMA-IR levels are slightly higher in women with breast cancer.
Celotno besedilo
Dostopno za:
DOBA, IZUM, KILJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK