The determination of trace elements, particularly rare earth elements, in uranium ore concentrates (UOCs) is important as the pattern can be indictive ore characteristics. Presented here is a ...methodology for accurately quantifying rare earth elements (REE) in UOCs. To improve the measurement uncertainty, isotope dilution mass spectrometry (IDMS) was utilized over other quantification techniques such as external calibration or standard addition. The isotopic determinations were measured by inductively coupled plasma-mass spectrometry (ICP-MS). To obtain high-fidelity isotopic measurements, separation of the REE from the uranium matrix was achieved by high-performance ion chromatography (HPIC), reducing the isobaric interferences. After separation, the target analytes were analyzed in two different modalities. For high precision analysis, the separated analytes were collected and measured by ICP-MS in an “offline” fashion. For a rapid approach, the separated analytes were sent directly into an ICP-MS for “online” analysis. These methods have been demonstrated to accurately quantify the REE content in a well-characterized UOC sample.
Automated introduction platforms integrated with inductively coupled plasma optical emission spectroscopy (ICP-OES) systems are continuously being improved. Expanding on the introduction systems, a ...newly developed automated ion chromatography system was explored for performing rapid in-line separations coupled to ICP-OES for the detection of trace elements in uranium. Trace elements are separated from a uranium material and the analytes are directed into the ICP-OES for subsequent detection. Detection parameters such as exposure time frequency, wavelength selection, and settling times were explored to gain insight on optimal detection schemes for in-line trace elemental analysis. The methodology was applied in the analysis of a uranium oxide (U3O8) certified reference material, CRM-124. It was found here that the sensitivity and uncertainty of the technique are greatly affected by how the ICP-OES is employed to collect data. Overall it was determined that faster exposure replicates can provide greater peak resolution with higher fidelity measurements but are limited with respect to the total analysis time (i.e., limited in detection timely separations). Zeta scores, which combine accuracy and uncertainty of certified values and experimental values, were used to validate the ICP-OES modes of operation.
A microextraction liquid sampling system coupled to a quadrupole inductively coupled plasma-mass spectrometer (ICP-MS) was utilized to spatially discern uranium particles, isotopically, on a ...cellulose-based swipe material (
i.e.
, J-type swipe). These types of swipes are often used by the International Atomic Energy Agency (IAEA) as part of their environmental sampling program. A grid was created such that extraction locations covered the center circle (
n
= 34 without overlapping). Uranium (U) particulates (<20 μm) of varying U isotopic abundance and chemical form (
i.e.
, uranyl fluoride and uranyl nitrate hexahydrate) were mechanically placed on the swipes in random locations and detected
via
the microextraction-ICP-MS methodology. Heat maps were subsequently generated to show the placement of the particulate with their respective intensity and isotopic determination. This detection of the uranium particulates,
via
isotopic determination, agreed with reference values for these materials. Additionally, depleted (
235
U/
238
U = 0.002) uranium particulates were placed directly within a clay matrix, on the swipe surface, and subjected to analysis by microextraction-ICP-MS. The mapping of the swipe demonstrated, for the first time, the employment of the microextraction-ICP-MS method for extracting sample from a complex matrix, and correctly identifying the uranium isotopic composition. This example ultimately demonstrates the utility of the methodology for detecting particles of interest in complex matrices.
A microextraction sampling system coupled to a quadrupole inductively coupled plasma-mass spectrometer (ICP-MS) was utilized to spatially discern uranium particles, isotopically, on a cellulose-based swipe material (
i.e.
, J-type swipe).
The trace impurities of a uranium ore concentrate (UOC) can be examined to determine mine source, methods of production, and quality. This study presents a method to determine the concentration of ...halides and main group elements, specifically P, S, Br and I, utilizing triple quadrupole inductively coupled plasma–mass spectrometry. These analytes were measured in a uranium matrix to simulate a UOC sample. The concentrations determined with this method showed agreement with known values. Solutions with and without uranium were compared. A UOC certified reference material, CUP-2, was analyzed to further demonstrate the effectiveness of the method.
The present study documents an automated approach to performing elemental analysis on a large group uranium ore concentrate (UOC) samples. Here, 17 UOC samples, 2 quality control samples, and 26 ...process blanks were purified sequentially through a single 500 μL Uranium and TEtra Valent Actinides (UTEVA®) column. For each sample, the trace elemental impurities were separated from its dissolved uranium matrix on the UTEVA column and collected for analysis by inductively coupled plasma – optical emission spectroscopy / triple quadrupole mass spectrometry (ICP-OES/TQMS). The UTEVA column was subsequently regenerated prior to separation of the following sample. The column was efficiently regenerated, for each UOC, even after processing ~50 mg of uranium, cumulatively. The validity of the method was established by determining the trace impurities of two quality control uranium reference samples (CRM 124–1 and CUP-2). The current trace element measurements from the 17 UOC samples were compared to previously reported values from an interlaboratory comparison exercise, when available. The methodology employed here produces trace elemental analysis with excellent correlation to the previously reported data for many of the elements / samples, particularly when viewed through the context of existing geochemical comparisons tools (e.g. chondrite normalized variation plots).
Display omitted
•Automated platform for separation of bulk uranium from trace elemental impurities•Employment of ICP-OES and ICP-MS (specifically triple quadrupole technology) for elemental analysis•Analysis of 17 uranium ore concentrates (UOCs) for their elemental composition
The liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source has proven to be an effective analysis tool for making uranium isotope ratio measurements when coupled to ...high-resolution mass spectrometers, such as the Orbitrap. While previous studies have shown the capabilities of the LS-APGD for isotope ratio determination, a systematic evaluation of the measurement uncertainty of the technique has not been conducted. To this end, the International Standards Organizations (ISO) guidelines to the expression of uncertainty in measurement (GUM analysis) have been applied to generate an uncertainty budget. Presented here, a preliminary assessment derived from the GUM analysis was performed. The uncertainty in the instrument blank determination has been identified as a primary factor contributing to measurement uncertainty for the LS-APGD-Orbitrap method. These findings for the specific test case of uranium isotopic analysis will be invaluable in applications across the breadth of isotope ratio mass spectrometry performed on this unique instrumental platform.
Graphical abstract
This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as ...a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm
2
), and delivers solvent (2% HNO
3
) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition (
240
Pu/
239
Pu and
242
Pu/
239
Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the
240
Pu/
239
Pu ratio on all three CRMs and <10% for the
242
Pu/
239
Pu ratio on CRM 136 and 138. The percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the
240
Pu/
239
Pu and <15% for the
242
Pu/
239
Pu. Method limits of detection were determined, based on measurements of an enriched
244
Pu material, to be ∼7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.
This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe.
Small carbon clusters (C n , n = 2−15) are produced in a molecular beam by pulsed laser vaporization and studied with vacuum ultraviolet (VUV) photoionization mass spectrometry. The required VUV ...radiation in the 8−12 eV range is provided by the Advanced Light Source (ALS) at the Lawrence Berkeley National Laboratory. Mass spectra at various ionization energies reveal the qualitative relative abundances of the neutral carbon clusters produced. By far the most abundant species is C3. Using the tunability of the ALS, ionization threshold spectra are recorded for the clusters up to 15 atoms in size. The ionization thresholds are compared to those measured previously with charge-transfer bracketing methods. To interpret the ionization thresholds for different cluster sizes, new ab initio calculations are carried out on the clusters for n = 4−10. Geometric structures are optimized at the CCSD(T) level with cc-pVTZ (or cc-pVDZ) basis sets, and focal point extrapolations are applied to both neutral and cation species to determine adiabatic and vertical ionization potentials. The comparison of computed and measured ionization potentials makes it possible to investigate the isomeric structures of the neutral clusters produced in this experiment. The measurements are inconclusive for the n = 4−6 species because of unquenched excited electronic states. However, the data provide evidence for the prominence of linear structures for the n = 7, 9, 11, 13 species and the presence of cyclic C10.
Information about elemental and isotopic systematics of ultra-trace level actinides (
e.g.
U and Pu) and main group elements (
e.g.
Ti) present within nuclear grade graphite is vital to the nuclear ...community for improved reactor operation and security. In support of this, extensive effort has been placed on improving analysis methods (
i.e.
, inductively coupled plasma-mass spectrometry). However, significantly less effort has been devoted to the optimization of chemical separation methods. Within the separation community, commercially available Eichrom™ resins are often employed, as their elution characteristics for various elements have been well studied, but the direct optimization of actinides and trace metal separations from a single sample have not been widely investigated. Here, methods using various Eichrom pre-packed cartridges were explored to achieve separation of ultra-trace levels of U, Pu, and Ti from a variety of graphite samples. Once the validity of the combined separation scheme was established using certified reference materials, the method was applied to historic, unirradiated and irradiated, graphite samples. For all samples investigated, precise isotope ratio measurements for the titanium isotope systems were made.
Purification of plutonium, uranium, and titanium from high-purity graphite for high precision isotopic analysis
via
MC-ICP-MS.
Presented here is a novel automated method for determining the trace element composition of bulk thorium by inductively coupled plasma–optical emission spectroscopy (ICP-OES). ICP-OES is a universal ...approach for measuring the trace elemental impurities present in actinide-rich materials; however, due to the emission rich spectrum of the actinide, a separation from the trace elements is warranted for spectrochemical analysis. Here, AG MP-1 ion exchange resin was utilized for retention of the Th matrix, while allowing the trace element impurities to be separated prior to subsequent analysis using ICP-OES. After demonstrating the separation on traditional gravity-driven columns, the methodology was transitioned to an automated platform for comparison. This automated platform utilizes syringe-driven sample and solvent flow and can collect the trace element and thorium fractions in separate locations. While reducing the sample size (500 µL, 1.5 mg of Th), maintaining the overall separation efficiency (recoveries >95%), and illustrating the sample throughput ability (n = 10+), this automated methodology could be readily adopted to nuclear facilities in which the determination of trace elemental impurities in Th samples is warranted.