A NanoSIMS 50 L was used to study the relationship between the 235U/238U atomic and 235U16O/238U16O molecular uranium isotope ratios determined from a variety of uranium compounds (UO2, UO2F2, UO3, ...UO2(NO3)2·6(H2O), and UF4) and silicates (NIST-610 glass and the Plesovice zircon reference materials, both containing µg/g uranium). Because there is typically a greater abundance of 235U16O+ and 238U16O+ molecular secondary ions than 235U+ and 238U+ atomic ions when uranium-bearing materials are sputtered with an oxygen primary ion beam, the goal was to understand whether use of 235U16O/238U16O has the potential for improved accuracy and precision when compared to the 235U/238U ratio. The UO2 and silicate reference materials showed the greatest potential for improved accuracy and precision through use of the 235U16O/238U16O ratio as compared to the 235U/238U ratio. For the UO2, which was investigated at a variety of primary beam currents, and the silicate reference materials, which were only investigated using a single primary beam current, this improvement was especially pronounced at low 235U+ count rates. In contrast, comparison of the 235U16O/238U16O ratio versus the 235U/238U ratio from the other uranium compounds clearly indicates that the 235U16O/238U16O ratio results in worse precision and accuracy. This behavior is based on the observation that the atomic (235U+ and 238U+) to molecular (235U16O+ and 238U16O+) secondary ion production rates remain internally consistent within the UO2 and silicate reference materials, whereas it is highly variable in the other uranium compounds. Efforts to understand the origin of this behavior suggest that irregular sample surface topography, and/or molecular interferences arising from the manner in which the UO2F2, UO3, UO2(NO3)2·6(H2O), and UF4 were prepared, may be a major contributing factor to the inconsistent relationship between the observed atomic and molecular secondary ion yields. Overall, the results suggest that for certain bulk compositions, use of the 235U16O/238U16O may be a viable approach to improving the precision and accuracy in situations where a relatively low 235U+ count rate is expected.
The infrared spectra of protonated acetone and the proton bound acetone dimer are obtained revealing vibrational resonances associated with the shared proton motions, which are in agreement with the ...predictions from ab initio, MP2, harmonic frequency calculations.
Small carbon clusters (Cn, n = 2-15) are produced in amolecular beam by pulsed laser vaporization and studied with vacuumultraviolet (VUV) photoionization mass spectrometry. The required VUVradiation ...in the 8-12 eV range is provided by the Advanced Light Source(ALS) at the Lawrence Berkeley National Laboratory. Mass spectra atvarious ionization energies reveal the qualitative relative abundances ofthe neutral carbon clusters produced. By far the most abundant species isC3. Using the tunability of the ALS, ionization threshold spectra arerecorded for the clusters up to 15 atoms in size. The ionizationthresholds are compared to those measured previously with charge-transferbracketing methods. To interpret the ionization thresholds for differentcluster sizes, new ab initio calculations are carried out on the clustersfor n = 4-10. Geometric structures are optimized at the CCSD(T) levelwith cc-pVTZ (or cc-pVDZ) basis sets, and focal point extrapolations areapplied to both neutral and cation species to determine adiabatic andvertical ionization potentials. The comparison of computed and measuredionization potentials makes it possible to investigate the isomericstructures of the neutral clusters produced in this experiment. Themeasurements are inconclusive for the n = 4-6 species because ofunquenched excited electronic states. However, the data provide evidencefor the prominence of linear structures for the n = 7, 9, 11, 13 speciesand the presence of cyclic C10.
This chapter focuses on the first metric, referred to as Max24Hours since it provides a 95% upper bound for the maximum temperature each node would reach if it ran High Performance Linpack (HPL) for ...24 hours. It presents approach to increasing data center (DC) energy efficiency. This includes a temperature monitoring infrastructure and a process for improving a DC's energy efficiency. High performance computing (HPC) DCs have been kept quite cool as this was thought to be conservative in terms of avoiding heat‐related compute equipment damage. The temperature monitoring infrastructure can provide early warning of increasing hardware temperatures. The chapter describes application of the temperature monitoring infrastructure to root cause determination when Mustang nodes suddenly experienced high temperatures, including temperatures that were close to or reached 70 °C, the temperature at which Mustang nodes automatically shut down.