Many extensions of the standard model of particle physics suggest that neutrinos should be Majorana-type fermions-that is, that neutrinos are their own anti-particles-but this assumption is difficult ...to confirm. Observation of neutrinoless double-β decay (0νββ), a spontaneous transition that may occur in several candidate nuclei, would verify the Majorana nature of the neutrino and constrain the absolute scale of the neutrino mass spectrum. Recent searches carried out with (76)Ge (the GERDA experiment) and (136)Xe (the KamLAND-Zen and EXO (Enriched Xenon Observatory)-200 experiments) have established the lifetime of this decay to be longer than 10(25) years, corresponding to a limit on the neutrino mass of 0.2-0.4 electronvolts. Here we report new results from EXO-200 based on a large (136)Xe exposure that represents an almost fourfold increase from our earlier published data sets. We have improved the detector resolution and revised the data analysis. The half-life sensitivity we obtain is 1.9 × 10(25) years, an improvement by a factor of 2.7 on previous EXO-200 results. We find no statistically significant evidence for 0νββ decay and set a half-life limit of 1.1 × 10(25) years at the 90 per cent confidence level. The high sensitivity holds promise for further running of the EXO-200 detector and future 0νββ decay searches with an improved Xe-based experiment, nEXO.
Celotno besedilo
Dostopno za:
DOBA, IJS, IZUM, KILJ, KISLJ, NUK, PILJ, PNG, SAZU, SIK, UILJ, UKNU, UL, UM, UPUK
EXO-200 is an experiment designed to search for double beta decay of super(136)Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the ...isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.
Abstract
The EXO-200 experiment searched for neutrinoless double-beta decay of
136
Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ...ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
In this trial involving patients with atherosclerotic disease who were receiving effective statin therapy, those who were assigned to receive anacetrapib, a CETP inhibitor, had a lower risk of major ...coronary events than did those in the placebo group.
In this trial, patients with an acute coronary syndrome within the previous 10 days were randomly assigned to simvastatin plus either ezetimibe or placebo. At a median of 6 years, the rate of ...cardiovascular events was modestly but significantly lower with simvastatin–ezetimibe.
The use of 3-hydroxy-3-methylglutaryl-coenzyme A reductase inhibitors (statins) reduces both low-density lipoprotein (LDL) cholesterol levels and the risk of cardiovascular events in patients with and those without cardiovascular disease.
1
–
4
Intensive statin therapy, as compared with moderate-dose statin therapy, incrementally lowers LDL cholesterol levels and rates of nonfatal cardiovascular events.
5
–
9
Because of the residual risk of recurrent cardiovascular events and safety concerns associated with high-dose statin therapy,
10
additional lipid-modifying therapies have been sought.
11
–
14
Ezetimibe targets the Niemann–Pick C1–like 1 (NPC1L1) protein, thereby reducing absorption of cholesterol from the intestine.
15
,
16
When added to statins, ezetimibe reduces LDL cholesterol . . .
A xenon gas purity monitor for EXO Dobi, A.; Hall, C.; Herrin, S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2011, Letnik:
659, Številka:
1
Journal Article
Recenzirano
Odprti dostop
We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of ...oxygen well below 1ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tungsten filament. Lab tests and experiences in commissioning the EXO-200 double beta decay experiment are described. These devices can also be used on other noble gases.
Tagging events with the coincident detection of a barium ion would greatly reduce the background for a neutrino-less double beta decay search in xenon. This paper describes progress towards realizing ...this goal. It outlines a source that can produce large quantities of Ba++ in gas, shows that this can be extracted to vacuum, and demonstrates a mechanism by which the Ba++ can be efficiently converted to Ba+ as required for laser identification.
We report on a search for neutrinoless double-beta decay of 136Xe with EXO-200. No signal is observed for an exposure of 32.5 kg yr, with a background of ∼1.5×10(-3) kg(-1) yr(-1) keV(-1) in the ...±1σ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay T(1/2)(0νββ)(136Xe)>1.6×10(25) yr (90% C.L.), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.