We report measurements of oscillation parameters from ν(μ) and ν(μ) disappearance using beam and atmospheric data from MINOS. The data comprise exposures of 10.71×10(20) protons on target in the ...ν(μ)-dominated beam, 3.36×10(20) protons on target in the ν(μ)-enhanced beam, and 37.88 kton yr of atmospheric neutrinos. Assuming identical ν and ν oscillation parameters, we measure |Δm2| = (2.41(-0.10)(+0.09))×10(-3) eV2 and sin2(2θ) = 0.950(-0.036)(+0.035). Allowing independent ν and ν oscillations, we measure antineutrino parameters of |Δm2| = (2.50(-0.25)(+0.23))×10(-3) eV2 and sin2(2θ) = 0.97(-0.08)(+0.03), with minimal change to the neutrino parameters.
We report on ν(e) and ν(e) appearance in ν(μ) and ν(μ) beams using the full MINOS data sample. The comparison of these ν(e) and ν(e) appearance data at a 735 km baseline with θ13 measurements by ...reactor experiments probes δ, the θ23 octant degeneracy, and the mass hierarchy. This analysis is the first use of this technique and includes the first accelerator long-baseline search for ν(μ) → ν(e). Our data disfavor 31% (5%) of the three-parameter space defined by δ, the octant of the θ23, and the mass hierarchy at the 68% (90%) C.L. We measure a value of 2sin(2)(2θ13)sin(2)(θ23) that is consistent with reactor experiments.
Materials such as a-Se, a-As(2)Se(3), GaSe, GaAs, Ge, CdTe, CdZnTe, Cd(0.8)Zn(0.2)Te, ZnTe, PbO, TlBr, PbI(2) and HgI(2) are potential candidates as photoconductors in direct detectors for digital ...mammography. The x-ray induced primary electrons inside a photoconductor's bulk comprise the initial signal that propagates and forms the final signal (image) on the detector's electrodes. An already developed model for a-Se has been properly extended to simulate the primary electron production in the materials mentioned. Primary electron characteristics, such as their energy, angular and spatial distributions that strongly influence the characteristics of the final image, were studied for both monoenergetic and polyenergetic x-ray spectra in the mammographic energy range. The characteristic feature in the electron energy distributions for PbI(2) and HgI(2) is the atomic deexcitation peaks, whereas for the rest of the materials their shape can also be influenced by the electrons produced from primary photons. The electrons have a small tendency to be forward ejected whereas they prefer to be ejected perpendicular (theta = pi/2) to the incident beam's axis and at two lobes around phi = 0 and phi = pi. At practical mammographic energies (15-40 keV) a-Se, a-As(2)Se(3) and Ge have the minimum azimuthal uniformity whereas CdZnTe, Cd(0.8)Zn(0.2)Te and CdTe the maximum one. The spatial distributions for a-Se, a-As(2)Se(3), GaSe, GaAs, Ge, PbO and TlBr are almost independent of the polyenergetic spectrum, while those for CdTe, CdZnTe, Cd(0.8)Zn(0.2)Te, ZnTe, PbI(2) and HgI(2) have a spectrum dependence. In the practical mammographic energy range and at this primitive stage of primary electron production, a-Se has the best inherent spatial resolution as compared to the rest of the photoconductors. PbO has the minimum bulk space in which electrons can be produced whereas CdTe has the maximum one.
Magnification is a special technique applied in mammography in cases where breast complaints have already been noticed, aiming to examine a specific area of the breast. Small-sized focal spots are ...essential in such techniques in order to reduce the resultant geometrical unsharpness. The x-ray intensity distribution of the focal spot is another crucial parameter for such a technique as it affects the mammographic resolution. In this study a Monte Carlo simulation model is utilized, in order to examine the effect of a wide range of focal spot sizes and three representative intensity distributions on spatial resolution under magnification. A thick sharp edge consisting of lead, non-transparent to x-rays was imaged under various conditions for this purpose, and the corresponding spatial resolution was calculated through the modulation transfer function (MTF). Results demonstrate that focal spots larger than 0.10 mm can mainly be used for low degrees of magnification, especially when combined with double peak Gaussian intensity distribution of the focal spot (sum of two single peak Gaussian distributions with different centers), as the resultant spatial resolution is not as high as the corresponding from smaller foci or uniform and single peak Gaussian distributions. Moreover, for the degrees of magnification usually utilized in clinical practice they do not reach the acceptable limit of 12 lp mm(-1). The replacement of the x-ray tube when the focal spot starts being destroyed is very crucial as the possible alteration of single peak Gaussian distribution to double peak Gaussian results in the degradation of spatial resolution. A focal spot of 0.10 mm or smaller, combined with single peak Gaussian intensity distribution, can be considered appropriate even for higher degrees of magnification and its use can contribute in the effort to optimize the magnification views in mammography.
Magnification views are a common way to perform a secondary examination when suspicious abnormalities are found in a screening mammogram. The visibility of microcalcifications and breast lesions is ...restricted by the compromise between the image quality and the absorbed dose. In this study, image quality characteristics in magnification mammography were evaluated based on Monte Carlo techniques. A breast phantom was utilized, simulating a homogeneous mixture of adipose and glandular tissue in various percentages of glandularity, containing inhomogeneities of various sizes and compositions. The effect of the magnification degree, breast glandularity, tube voltage and anode/filter material combination on image quality characteristics was investigated in terms of a contrast-to-noise ratio (CNR). A performance index PI(nu) was introduced in order to study the overall performance of various anode/filter combinations under different exposure parameters. Results demonstrate that CNR is improved with the degree of magnification and degraded as the breast glandularity is increased. Degree of magnification 1.3 offers the best overall performance for most of the anode/filter combinations utilized. Under magnification conditions, the role of dose is demoted against the image quality, as magnification views are secondary, diagnostic examinations and not screening procedures oriented to non-symptomatic women. For decreased image quality weighting, some anode/filter combinations different from Mo/0.030 mmMo can be utilized as they offer a similar performance index. However, if the desired weighting for the image quality is high, the Mo/0.030 mmMo combination has the best overall performance.
A search for mixing between active neutrinos and light sterile neutrinos has been performed by looking for muon neutrino disappearance in two detectors at baselines of 1.04 and 735 km, using a ...combined MINOS and MINOS+ exposure of 16.36×10^{20} protons on target. A simultaneous fit to the charged-current muon neutrino and neutral-current neutrino energy spectra in the two detectors yields no evidence for sterile neutrino mixing using a 3+1 model. The most stringent limit to date is set on the mixing parameter sin^{2}θ_{24} for most values of the sterile neutrino mass splitting Δm_{41}^{2}>10^{-4} eV^{2}.
Magnification mammography is a special technique used in the cases where breast complaints are noted by a woman or when an abnormality is found in a screening mammogram. The carcinogenic risk in ...mammography is related to the dose deposited in the glandular tissue of the breast rather than the adipose, and average glandular dose (AGD) is the quantity taken into consideration during a mammographic examination. Direct measurement of the AGD is not feasible during clinical practice and thus, the incident air KERMA on the breast surface is used to estimate the glandular dose, with the help of proper conversion factors. Additional conversion factors adapted for magnification and tube voltage are calculated, using Monte Carlo simulation. The effect of magnification degree, tube voltage, various anode/filter material combinations and glandularity on AGD is also studied, considering partial breast irradiation. Results demonstrate that the estimation of AGD utilizing conversion factors depends on these parameters, while the omission of correction factors for magnification and tube voltage can lead to significant underestimation or overestimation of AGD. AGD was found to increase with filter material's k-absorption edge, anode material's k-emission edge, tube voltage and magnification. Decrease of the glandularity of the breast leads to higher AGD due to the increased penetrating ability of the photon beam in thick breasts with low glandularity.
We report results from the first search for ν_{μ}→ν_{e} transitions by the NOvA experiment. In an exposure equivalent to 2.74×10^{20} protons on target in the upgraded NuMI beam at Fermilab, we ...observe 6 events in the Far Detector, compared to a background expectation of 0.99±0.11(syst) events based on the Near Detector measurement. A secondary analysis observes 11 events with a background of 1.07±0.14(syst). The 3.3σ excess of events observed in the primary analysis disfavors 0.1π<δ_{CP}<0.5π in the inverted mass hierarchy at the 90% C.L.