In 2021, the world's total installed capacity of generation units based on renewable energy sources (not including hydropower) amounted to about 1674 GW: over 825 GW and 849 GW of wind and solar ...power plants were installed respectively. The growing of the installed capacity of these distributed generators is a response to the increasing the power consumption, global environmental issues and has also become possible due to the development of technology in field of power semiconductor devices. However, on the way of large-scale implementation of distributed generators based on renewable energy sources, traditional electric power system meets new challenges to ensure the reliability and sustainability of new electric power systems with renewable energy sources. In particular, distributed generators change processes in the electric power system, impact to the parameters and power balance, change the magnitude and direction of power flow and short-circuit current, which determines the need to update the settings of the relay protection and automation systems of traditional electric power system and to coordinate their operation with automatic control systems of installed distributed generators. The above-mentioned tasks form a number of scientific research directions, one of which is a task of determining optimal size and location of distributed generators. The main purpose of this optimization task is to reduce power losses, operating and total electricity cost, improve the voltage profile, etc. In addition, the correct and reasonable placement of distributed generators defines an effective planning of the operating modes of electric power system and power plants (especially based on renewable energy sources, the operating modes of which depend on weather conditions and can be sharply variable).
The paper highlighted the impacts of distributed generators on power losses, the voltage level, maintaining the power balance and the possibility of participating in the frequency regulation, and short-circuit current in power system. The optimization criteria, the main limiting conditions, as well as methods for solving this optimization problem are considered. This review will help the System operators and investing companies, especially in Russia, to form the main aim, objective function and constraints that will aid to meet their load demand at minimum cost and to choose from the options available for optimization of location and capacity of distributed generators.
Nowadays the trend of increasing the generation units based on renewable energy sources in the electric power system can be observed. Obviously, this is due to the intensifying level of consumer load ...and demand for electricity. However, renewable generation is characterized by intermittent energy production, which can cause and potential imbalance between generation and demand, especially during off-peak periods. Therefore, in order to ensure a reliable power supply to consumers, it is necessary to use a maneuverable reserve of capacity, such as energy storage systems, in conjunction with the renewable energy source unit. Over the past 10 years, the energy storage market has grown by almost 50%: the installed capacity of energy storage system in the world is about 5 GW. Analysis of the literature on the subject determines the need to study the impact of these devices on the parameters of electric power systems and one of the primary tasks is to determine the optimal location and capacity of energy storage system in the power system. This paper presents the result of solving the task of determining the optimal parameters of a hydrogen energy storage system using the particle swarm optimization method for example a test scheme radial distribution system – 33 bus IEEE. The choice of the type of energy storage is based on such advantages of a hydrogen energy storage system as environmental friendliness, high energy capacity and the ability to store electricity for a long period of time. In addition, compared to lithium-ion batteries, hydrogen energy storage systems have a long life time of about 25 years, during this period of time there is no degradation and significant deterioration of its properties. All these advantages of hydrogen as an energy carrier allow to take into account not only the criterion of total value of active power losses and its maximum reduction respectively, but the possibility and economic efficiency of partial use of the stored hydrogen for other needs when determining the optimal scenario of their operation in the process of discharge.
The global climate and environmental crisis dictate the need for the development and implementation of environmentally friendly and efficient technical solutions, for example, generation based on ...renewable energy sources. However, the annually increasing demand for electricity (according to the forecasts of the U.S. Energy Information Administration, the amount of energy consumed for the period 2006–2030 will increase by 44 %) cannot be fully provided by alternative energy. The main reason is not so much the high cost of these technologies, like unstable power generation, which determines the need for an additional reserve of regulated power.
The solution to this problem can be the combined use of generation based on renewable energy sources with energy storage units of large capacity. Currently, a promising direction is the use of excess electricity for the production of hydrogen and its further accumulation in hydrogen storage. In this case an additional energy can be generated using industrial fuel cells (electrochemical generators) to compensate for the power shortage.
At the same time, the distinctive advantage of hydrogen energy storage systems lies in the ability to accumulate a large amount of energy for long periods of time. This fact makes it possible to increase the reliability of the functioning of the electric power system, to provide power supply with a sufficiently long interruption (in case of faults) or allocation for isolated operation.
With an increase in the unit capacity and the share of renewable generation in the total installed capacity, researches that aimed to systematic analysis of the impact of the implemented generation unit and the energy storage system on the parameters of the mode of the electric power system become more relevant. There are a number of tasks can be noted related to determining the optimal location and size of the generation unit and energy storage systems being implemented in terms of reducing power losses and maintaining an appropriate voltage level in the nodes of the electric power system. In this article, a variant of solving the optimization task for a typical 15-bus IEEE scheme is presented by means of software calculation using the bubble sorting method. To achieve this goal, the following tasks were solved: the objective function, which indicates the optimal location and size of the generation unit, and constraints, for example, the available deviation of voltage level, were formed; the software implementation of the algorithm for calculating power flows and power losses using the bubble sorting method was carried out. The results of the work of the program code for two scenarios are presented: for instance, installation of one renewable generation unit with a different range of possible capacities, and are compared with the data obtained in the MATLAB/Simulink software package.
Nowadays, the development of the electric power system is associated with the penetration of power generation units based on renewable energy sources and operated with energy storage systems. ...However, the operation of such generation units changes and complicates the processes in the electric power system, which determines the need for a number of studies and analyses. This paper presents the results of assessing the impact of the operation of photovoltaic plants on the static stability of the electric power system. To achieve the goal, the EUROSTAG software was used. The results of studies of normal and post-emergency modes of electric power system with the different penetration level of generation units are presented, power system stability coefficients of active power and voltage are determined, damping properties of electric power system based on the calculation of the transient damping coefficient of the damping process are estimated.
Energy storage systems are increasingly used as part of electric power systems to solve various problems of power supply reliability. With increasing power of the energy storage systems and the share ...of their use in electric power systems, their influence on operation modes and transient processes becomes significant. In this case, there is a need to take into account their properties in mathematical models of real dimension power systems in the study of various operation modes, design, etc. In this article the main types of energy storage devices, as well as the fields and applications of their use in electric power systems are considered. The principles of realization of detailed mathematical models, principles of their control systems are described for the presented types of energy storage systems. The article is an overview and can help in choosing a mathematical model of energy storage system to solve the necessary tasks in the mathematical modeling of storage systems in electric power systems.
Information is presented on large hydrogen energy storage units for use in the power system.